• Title/Summary/Keyword: paper sensor

Search Result 12,481, Processing Time 0.058 seconds

Development of Eco-friendly Paper Glucose Sensor Using Printing Technology (인쇄 기술을 이용한 친환경 종이 혈당 센서 스트립 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.116-120
    • /
    • 2020
  • In this paper, we developed an electrochemical glucose sensor strip using a paper substrate. The paper glucose sensor strip is eco-friendly because it uses paper as a substrate, and it has the advantage that it can be manufactured only with four printing, drying and cutting processes. The paper glucose sensor is significantly simplified by the production process than the conventional glucose sensors because the production of only four printing on the paper substrate. In this paper, eco-friendly tracing paper was used to develop a paper glucose sensor strip, and screen-printing technology was used to form a carbon/silver electrode, insulating layer and glucose oxidase(GOD) layer. The developed paper glucose sensor strip has a flat structure with a size of 30 × 4.6 ㎟, and blood injection is a type of direct contact with the exposed enzyme layer above the strip. In this paper, the performance of paper glucose sensor strips was evaluated by analyzing the cyclic voltammetry(CV) and chronoamperometry(CA) characteristics.

Improved Resolution of Paper-based Sensor for Proline Detection by Low-temperature Drying of Ninhydrin Solution (닌히드린 용액의 저온 건조에 의한 프롤린 검출을 위한 종이기반 센서의 분해능 개선)

  • Ji-Kwan, Kim;Young-Soo, Choi
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.428-432
    • /
    • 2022
  • In this study, we describe the improvement of the resolution of a paper-based sensor by fabricating a high-concentration ninhydrin part using a low-temperature drying method to detect proline with high resolution. In the conventional paper-based sensor for detecting proline, the ninhydrin part is fabricated at room temperature, and in this process, the ninhydrin solution spreads around the ninhydrin part. Therefore, the concentration of the ninhydrin part becomes lower than that of the applied solution, lowering the resolution of the sensor. The proposed paper-based sensor better improved the sensitivity of the sensor compared to the existing sensor by fabricating a high-concentration ninhydrin part through drying the ninhydrin solution using a low-temperature drying method. Owing to the experiment, the intensity of the green color of the paper-based sensor with the integrated ninhydrin part fabricated at 10 ℃ is approximately 20% lower than the paper-based sensor with an integrated ninhydrin part fabricated at room temperature, indicating better sensor resolution. Therefore, the paper-based sensor with an integrated ninhydrin part fabricated at a high concentration could be useful for diagnosing drought.

Development of Eco-Friendly Paper Glucose Bio-Sensor (친환경 종이 혈당 비이오센서 개발)

  • Kim, A-Young;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.202-206
    • /
    • 2013
  • In this paper, a disposable glucose sensor was made of paper. Glucose sensor strip using carbon electrode is appropriate for the low price ones because it requires cheap materials and low cost production. Most of blood glucose sensors were developed with plastics, but it causes pollution problems. Therefore we developed disposable carbon electrode glucose sensor using paper. This sensor consists of upper and bottom plate. On the upper plate, three-dimensional channel are formed through pressing process. The fabricated paper glucose sensor shows relatively short sensing time of about 5seconds, excellent reproducibility ($R^2$=0.9558), and fabrication yield as well.

Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect (헤마토크릿 영향을 최소화한 종이 혈당센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

COSMOS: A Middleware for Integrated Data Processing over Heterogeneous Sensor Networks

  • Kim, Ma-Rie;Lee, Jun-Wook;Lee, Yong-Joon;Ryou, Jae-Cheol
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.696-706
    • /
    • 2008
  • With the increasing need for intelligent environment monitoring applications and the decreasing cost of manufacturing sensor devices, it is likely that a wide variety of sensor networks will be deployed in the near future. In this environment, the way to access heterogeneous sensor networks and the way to integrate various sensor data are very important. This paper proposes the common system for middleware of sensor networks (COSMOS), which provides integrated data processing over multiple heterogeneous sensor networks based on sensor network abstraction called the sensor network common interface. Specifically, this paper introduces the sensor network common interface which defines a standardized communication protocol and message formats used between the COSMOS and sensor networks.

  • PDF

Visual Control of Mobile Robots Using Multisensor Fusion System

  • Kim, Jung-Ha;Sugisaka, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.91.4-91
    • /
    • 2001
  • In this paper, a development of the sensor fusion algorithm for a visual control of mobile robot is presented. The output data from the visual sensor include a time-lag due to the image processing computation. The sampling rate of the visual sensor is considerably low so that it should be used with other sensors to control fast motion. The main purpose of this paper is to develop a method which constitutes a sensor fusion system to give the optimal state estimates. The proposed sensor fusion system combines the visual sensor and inertial sensor using a modified Kalman filter. A kind of multi-rate Kalman filter which treats the slow sampling rate ...

  • PDF

Performance Improvement of the Sensor Registry System based on Sensor Metadata Reusability and Scoping (센서 메타데이터 영역화 및 재사용성 기반 센서 레지스트리 시스템 성능 향상 방법)

  • Jeong, Dongwon
    • The Journal of Korean Association of Computer Education
    • /
    • v.15 no.6
    • /
    • pp.75-82
    • /
    • 2012
  • The sensor registry system has been proposed to interpret and process semantics of sensor data independently of heterogeneous sensor networks. However, the existing sensor registry system provides the static processing method. In other words, the existing system reduces the overall performance because it executes unnecessary operations and does not consider data scope to be used. To resolve the problem of the existing sensor registry system, this paper proposes a performance enhancement model based on sensor metadata reusability and scoping. The proposed model in this paper provides a function that can decide a proper scope of sensor metadata from the sensor registry system. The proposed model improves the overall performance by providing reusability of sensor metadata. This paper also shows the advantages of the proposed model through the comparative performance evaluation.

  • PDF

Sensor Fault Detection and Analysis of Fault Status using Smart Sensor Modeling

  • Kim, Sung-Shin;Baek, Gyeong-Dong;Lee, Soo-Jin;Jeon, Tae-Ryong
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.207-212
    • /
    • 2008
  • There are several sensors in the liquid cargo ship. In the liquid cargo ship, we can get values from various sensors that are level sensor, temperature sensor, pressure sensor, oxygen sensor, VOCs sensor, high overfill sensor, etc. It is important to guarantee the reliability of sensors. In order to guarantee the reliability of sensors, we have to study the diagnosis of sensor fault. The technology of smart sensor is widely used. In this paper, the technology of smart sensor is applied to diagnosis of level sensor fault for liquid cargo ship. In order to diagnose sensor fault and find the sensor position, in this paper, we proposed algorithms of diagnosis of sensor fault using independent sensor diagnosis unit and self fault diagnosis using sensor modeling. Proposed methods are demonstrated by experiment and simulation. The results show that the proposed approach is useful. Proposed methods are useful to develop smart level sensor.

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.

Performance Evaluation according to Optical Power of Laser Diode of Optical Fiber Displacement Sensor for Monitoring High Speed Spindle. (고속주축 모니터링용 광파이버 변위센서의 레이저 다이오드 출력에 따른 성능평가)

  • 박찬규;신우철;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.376-380
    • /
    • 2004
  • This paper is to develop an optical ruer displacement sensor for monitoring high speed spindle. Proper magnitude of optical power as well as amplification of output signal are necessary to improve sensitivity of the sensor. In this paper, to meet the need of improvement of the sensor resolution, we choose proper optical power and amplification level through speculating on optical power of a laser diode.

  • PDF