• Title/Summary/Keyword: pantagraph

Search Result 21, Processing Time 0.034 seconds

The Study of Tilting Control System for Tilting Vehicle (틸팅차량 틸팅제어장치 연구)

  • Lee, Su-Gil;Han, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.253-255
    • /
    • 2005
  • Tilting trains are now an established feature of railway operations throughout the world. For intercity traffic, tilt provides operators with increasing speeds, and therefore enhanced competitiveness, on existing routes where insufficient traffic or a lack of funds precludes the construction of a dedicated new high-speed railway. Appling the tilting train, we can expect 30% of speed up on existing lines, but the stability of the electric current would be low because of tilting the train. Also, the spark between the catenary and pantagraph cause environmental problems such as noise, radio wave malfunction. Therefore, the tilting on pantagraph for the power suppling device is very essential for stable electric power supply.

  • PDF

The Study of Tilting Control System for EMU Tilting Vehicle (전기식 틸팅차량의 틸팅제어장치 구성방안 연구)

  • Lee Su-Gil;Han Seong-Ho;Song Yong Soo;Lee Woo-Dong;Han Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1457-1459
    • /
    • 2004
  • Tilting trains are now an established feature of railway operations throughout the world. For intercity traffic, tilt provides operators with increasing speeds, and therefore enhanced competitiveness, on existing routes where insufficient traffic or a lack of funds precludes the construction of a dedicated new high-speed railway. Appling the tilting train, we can expect $30\%$ of speed up on existing lines, but the stability of the electric current would be low because of tilting the train. Also, the spark between the catenary and pantagraph cause environmental problems such as noise, radio wave malfunction. Therefore, the tilting on pantagraph for the power suppling device is very essential for stable electric power supply.

  • PDF

The Study of Tilting Control System for Conventional Rail Speed-Up (기존선 속도향상을 위한 틸팅제어장치 개발에 관한 연구)

  • Lee, Su-Gil;Han, Seong-Ho;Song, Yong-Soo;Han, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.991-993
    • /
    • 2003
  • Tilting trains are now an established feature of railway operations throughout the world. For intercity traffic, tilt provides operators with increasing speeds, and therefore enhanced competitiveness, on existing routes where insufficient traffic or a lack of funds precludes the construction of a dedicated new high-speed railway. Appling the tilting train, we can expect 30% of speed up on existing lines, but the stability of the electric current would be low because of tilting the train. Also, the spark between the catenary and pantagraph cause environmental problems such as noise, radio wave malfunction. Therefore, the tilting on pantagraph for the power suppling device is very essential for stable electric power supply.

  • PDF

The Study of Tilting Control System for EMU Tilting Vehicle (틸팅전동차용 틸팅제어장치 개발에 관한 연구)

  • Lee, Su-Gil;Han, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1628-1630
    • /
    • 2005
  • Tilting trains are now an established feature of railway operations throughout the world. For intercity traffic, tilt provides operators with increasing speeds, and therefore enhanced competitiveness, on existing routes where insufficient traffic or a lack of funds precludes the construction of a dedicated new high-speed railway. Appling the tilting train, we can expect 30% of speed up on existing lines, but the stability of the electric current would be low because of tilting the train. Also, the spark between the catenary and pantagraph cause environmental problems such as noise, radio wave malfunction. Therefore, the tilting on pantagraph for the power suppling device is very essential for stable electric power supply.

  • PDF

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

Vibration Test Result and Consideration for AUTS(Advanced Urban Transit System (차세대전동차 진동시험 결과 및 고찰)

  • Hong, Jai-Sung;Kim, Gil-Dong;Lee, Chang-Mu;Won, Jong-Un;Lee, An-Ho;Sung, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2276-2279
    • /
    • 2011
  • The AUTS(Advanced Urban Transit System) are developed by government R&D business. This units are under main line performance test in Daebul test line. Both AC and DC could apply to the AUTS for pantagraph voltage. So main transformer and some high voltage filters are added to the under-frame. As a result the total weight of each car(Mc1-Tp1-M-T-Tp2-Mc2) is different. And axle load is different each other. The main characteristics of AUTS(Advanced Urban Transit System) are as follows. One inverter control one motor, DDM(Dircet Drive Motor), no driving gear, plug no end door, self-steering bogie etc. These matters could be appeared to strange vibration. So vibration test is important. The vibration test performed to Mc1 and Tp1. The results were checked to the up-down direction and left-right direction for acceleration.

  • PDF

Characteristics of High Speed Railway Noise (고속철도소음 특성)

  • Kang, Dae-Joon;Lee, D.G.;Jang, S.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.541-546
    • /
    • 2002
  • Railway noise is one of the main causes of environmental impact. Whenever a new railway line is planned or a housing project near an existing railway is proposed, an estimate of the relevant levels is usually required. For this, it is necessary to quantify those parameters that affect the railway noise. Therefore we investigated the noise and vibration level which 107 high speed trains generated passing through the block of test railway track between Chunan and Chungwon. This paper presents the status and characteristics of the high speed railway noise and an accurate prediction of the high speed railway noise.

  • PDF

Status and Characteristics of High Speed Railway Noise (고속철도소음 현황과 특성)

  • 이재원;박준철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1161-1165
    • /
    • 2004
  • Railway noise Is one of the main causes of environmental impact. Whenever a new railway line is planned or a housing project near an existing railway is proposed, an estimate of the relevant noise levels is usually required. For this, it is necessary to quantify those parameters that affect the railway noise. Therefore we investigated the noise level which 107 high speed trains generated passing through the block of test railway track between Chunan and Chungwon. This paper shows the status and characteristics of the high speed rallway noise and an accurate prediction of the high speed railway noise.

The Estimation of Structural-Borne Noise and Vibration of the Bridge under the Passage of the Light Rail Transit (경량전철 교량 상부구조의 열차주행에 대한 진동 및 소음 분석)

  • Yeo, In-Ho;Chung, Won-Seok;Kim, Sung-Choon;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.22-28
    • /
    • 2007
  • During the passage of the train, the railway bridge undergoes vibration and noise. The noise of railway bridge can be occurred from various sources. The wheel-rail contact, noise from machinery parts, structural-borne noise, pantagraph noise and aerodynamic noise of the train work in combination. Running train is one of the most important factors for railway bridge vibration. The repeated forces with equidistant axles cause the magnification of dynamic responses which relates with maintenance of the track structure and structure-borne noises. The noise problem is one of the most important issues in services of light rail transit system which usually passes through towns. In the present study, The vibration and noise of the LRT bridge will be investigated with utilizing dynamics responses from moving train as input data for noise analysis.

Analysis of AT Feeding Systems considering the Voltage Constraint Conditions of the Catenary. (전차선 전압제약조건을 고려한 AT 급전계통 해석)

  • Kim B.;Chung K. W.
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.27-33
    • /
    • 2005
  • Constant load model is generally used for an electric train to perform the static analysis of AT feeding systems. In this model, the train will be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However there must be some voltage constraints on the catenary in actual operations. These constraints are established for the reason of protecting the feeding facilities from excessive rise of regenerative braking voltage or guaranteeing the minimum traction power of train. In normal operating situation, the pantagraph voltage of the train should be maintained within these limits. Keeping these facts in minds, we suggest new methods of analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do. The proposed methods are believed to contribute to the assessment of TCR-TSC for compensating reactive powers too.

  • PDF