• 제목/요약/키워드: panel performance

검색결과 1,533건 처리시간 0.029초

국부 공진을 고려한 주름강판의 차음 설계 (Sound Insulation Design of the Corrugated Steel Panel Considering Local Resonance)

  • 김석현;이현우;김정태;김재철
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.672-676
    • /
    • 2010
  • In a railway vehicle, corrugated steel panel is widely used for the floor structure because of its high bending stiffness and light weight. However, this panel shows lower sound insulation performance than that of the flat plate with the same weight. Especially, in a particular frequency region, transmission loss(TL) rapidly decreases and it results in the deterioration of sound insulation performance of the overall floor structure. This study identifies that the severe decrease in TL is caused from the local resonance of the periodic corrugated structure. TL decrease by local resonance is investigated by experiment and finite element analysis. Finally, design modification of the corrugation is proposed to improve TL and the effect is verified by experiment.

변압기용 고효율 차음판의 진동 및 소음 비교 (Comparison of vibration and noise characteristic of high efficiency Insulation Panel for Transformer)

  • 정재환;장용석;임동수;김진;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.1005-1009
    • /
    • 2008
  • The high efficiency insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in side of city is appeared a lost of problem by increasing to conserve the living environment. Therefor in this paper, first the vibration and noise characteristic of existing insulation panel is analyzed according to attached material, cork and sponge-type. Second the insulation of sound performance is compared between the existing insulation panel. And high efficiency insulation panel that is proposal in this paper.

  • PDF

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

공공기술 이전, 기술적 성과, 연구개발 생산성 간의 구조적 관계 분석 (The Analysis of Structural Relationships among Public Technology Transfer, Technological Performance, and R&D Productivity)

  • 전지은;권상집
    • 지식경영연구
    • /
    • 제19권2호
    • /
    • pp.1-19
    • /
    • 2018
  • This study aims to identify the causal relationship among public technology transfer, technological performance, and research and development (R&D) productivity. Using the impulse-response function(IRF) of a panel vector autoregressive model (panel VAR), this study suggests the results of how long the factors such as technological performance (patent), public technology transfer, and R&D productivity takes and lasts if a one-unit shock of standard deviation occurs. As a result, first, the increase of public technology transfer activities has no power to increase the technology performance but improve the R&D productivity. If the public institute increases its technology transfer activities by one unit, the R&D productivity will increase within five years. Second, the impact of increasing technological performance on improvement of public technology transfer and R&D productivity is an insignificant. Third, the effect of R&D productivity on the public technology transfer creates a substantial reaction after a current time. Considering the structural relationships among public technology transfer, technological performance, and R&D productivity, if policy makers intend to construct the active R&D circumstance, technology suppliers should be motivated to run the active R&D mechanism because they achieve gains.

Empirical Study of Dynamic Chinese Corporate Governance Based on Chinese-listed Firms with A Panel VAR Approach

  • Shao, Lin;Zhang, Li;Yu, Xiaohong
    • 산경연구논집
    • /
    • 제8권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose - In this article, a dynamic model like a VAR is an appropriate choice for estimating the possible interrelationship between ownership structure and firm performance as a dynamic process. Research design, data, and methodology - Data of this work are collected from Chinese stock exchange including 350 Chinese-listed firms during the period of 1999-2012. We hypothesize that this interrelationship dynamically exists between ownership structure and firm performance. To examine the correlation, a panel Vector Auto-regression (PVAR) approach generated by GMM method is utilized to test the possible dynamic relation embedded in corporate governance. Another two dynamic analysis solutions such as orthogonalized impulse-response function and variance decomposition are also used simultaneously. Results - Findings of this study indicate the evidence that dynamically endogenous relationship exists between ownership structure and firm performance. Further, there is a dynamical correlation between investment and performance. Impulse response and variance decomposition illustrate that impact of a shock to variables themselves is the main source for their variability. Conclusions - The conclusion in this study is that there is a bidirectional and inter-temporal effect between proportion of ownership and corporate performance for a long run in accordance with impulse response function. Overall, our results suggest that corporate governance in China is more market oriented.

수입국 환경제도수준 변화가 수출에 미치는 영향 연구 (A study on the effect of changes in the level of environmental regulation of the importing country on export performance)

  • 황윤섭;유천
    • 무역학회지
    • /
    • 제45권4호
    • /
    • pp.65-81
    • /
    • 2020
  • Under New Climate Regime, countries are trying to enhance environmental regulations to meet international standards. This study is designed to examine the relationship between the relative level of environmental regulation of the importing countries and the export performance at the industrial level. Panel data from 2009 to 2018 was established for 12 top export industries and empirical analysis was conducted. For the analysis method, panel OLS, Hausman-Taylor, and panel GLS were used based on the results of the Hausman verification. The dependent variable is the export performance of each industry. As the independent variables, the relative level of environmental regulation, GDP per capita of the importing country, exchange rate, FTA agreement, and physical distance from the importing country were used. Results show that the relative level of environmental regulation has a negative effect on export performance of semiconductors, displays, special machines, general machines, electric appliances, and home appliances. On the other hand, there are no relationship between the relative level of environmental regulation of the importing country and export performance of automobile, petroleum refining, petrochemical, shipbuilding, and communication equipment industries.

저회를 이용한 경량패널의 현장 차음성능에 관한 실험 연구 (An experimental study on the field sound insulation performance of the light weight concrete panel using bottom ash)

  • 정진연;정갑철;이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.65-69
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Because of this reason, dry wall systems are used plentifully. This study examines the sound insulation performance of the light weight concrete panel using bottom ash. There is the difference of airborne sound isolation between laboratory and field test. For the purpose of searching deviation, we use the prediction tool(Insul 6.0). First, we calculated the prediction data and measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the difference.

  • PDF

태양열저장(太陽熱貯藏)을 위한 평판형잠열축열장치(平板形潛熱蓄熱裝置)의 성능분석(性能分析) (Performance Analysis of a Panel Type Latent Heat Storage Equipment for Solar Thermal Storage)

  • 김영복;주은선;윤여두;라우정
    • Journal of Biosystems Engineering
    • /
    • 제16권3호
    • /
    • pp.290-297
    • /
    • 1991
  • For the efficient utilization of the solar thermal energy to overcome the time gap between to supply and demand, an efficient heat storage technique, especially high density-latent-heat storage system, is necessary. In this study, the performance of a panel type latent heat storage equipment during heat discharging process was analyzed theoretically and experimentally. In order to find out the performance of the system, computer simulation programs were developed by finite difference method. The governing equations were constructed by two dimensional heat conduction model with moving boundary. The results of the experimental and the theoretical analysis were reasonably well agreed. The efficiencies of the double pipe type and the panel type latent heat storage equipment were compared.

  • PDF

수처리 시설물에 적용되는 섬유패널 배면부의 입체 성형 각도에 따른 부착 성능 연구 (A Study on the Adhesion Performance of Solid Forming Angle at Fiber Panel in the Water Supply Facility)

  • 윤준노;박완구;최수영;김동범;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.171-172
    • /
    • 2018
  • The purpose of this study is to confirm the adhesion performance of the three - dimensional forming fiber panels by the dimensional forming angle. As a result of applying the three dimensional surface shape to the back side of the fiber panel and testing the adhesion strength by the three dimensional forming angle, it was confirmed that the bonding strength of the specimens to which the dimensional molding was applied was higher than that of the non dimensional molding. In addition, the highest adhesion strength was confirmed in a specimen having a three-dimensional forming angle of 70 °.

  • PDF

반복 횡하중을 받는 프리캐스트 대형 판구조의 내진성능에 관한 연구 (Seismic Performance of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading)

  • 서수연;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.261-268
    • /
    • 1999
  • The seismic performance of precast concrete panel structures tested previously has been evaluated in this paper. Hysteretic curves of test specimens are idealized to elasto-plastic curves to get reliable yielding and ultimate displacements. For the idealized curves, ductility and energy dissipation capacity of specimens have been evaluated using a few guide lines. In addition, the strength capacity of specimens is checked for the strength demand caused by the design earthquake load including overturning moment effects. The result shows while the strength of specimen with joint box for vertical continuity is little bit lower than that of specimen connected by welding, the ductility of the former is higher than that of the latter. The energy dissipation ratios of PC specimens are ranged from 83% to 96% of that of Re specimen and the average of those are shown 90%.

  • PDF