Development and Evaluation of the Attrition Coupled Bioreactors for Enzymatic Hydrolysis of Biomass ; Horizontal Paddle Type Bioreactor for Enzymatic Hydrolysis of Cellulose (Biomass의 고효율 효소당화에 적합한 Attrition Coupled Bioreactor 개발에 관한 연구;Horizontal Paddle Type Bioreactor를 활용한 섬유소 당화)

  • 이용현;박진서
    • KSBB Journal
    • /
    • v.4 no.3
    • /
    • pp.215-220
    • /
    • 1989
  • To develop an attrition coupled enzyme reactor with high efficiency-low energy consumption for saccharification of insoluble biomass, a 5L horizontal paddle type bioreactor was constructed and its performance was evaluated. The optimal condition for saccharification of 50g $\alpha$ -cellulose/L was found to be 200rpm with 500g of 3mm glass bead. Especially, the horizontal paddle type bloreactor was very effective for saccharification of high concentration of insoluble cellulose, in which around 72% of $\alpha$ -cellulose was saccharified for 75g $\alpha$ -cellulose/L, and even up to 70% for 100g of $\alpha$ -cellulose/L after 24hours. Under the optimal condition, the power consumption was measured to be around 1.7watth/g. Horizontal paddle type bioreactor seems to have an appropriated structural feature for industrial scale operation and to be an effective and energy saving attrition coupled enzyme reactor.

  • PDF

Characteristic of Power Consumption for Paddle Impeller in Various Agitated Vessels (여러 가지 교반조에서 Paddle 임펠러의 교반소요동력 특성)

  • Lee, Young Sei;Kato, Yoshihito
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.698-704
    • /
    • 2005
  • Power consumption for paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained for both spherical and cylindrical vessels, where the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel (height equal to its diameter and had the same volume as the spherical vessel). The power consumption well correlated with the experimental results of Nagata, et al. and Hixson-Baum. Also the critical Reynolds numbers was directly related to the transition coefficient $C_{tr}$ characterizing the transition from a laminar to a turbulent flow region in the correlation proposed here.

헬리콥터 복합재료 힌지없는 허브 부품 및 패들형 블레이드 설계/해석

  • Kim, Deog-Kwan;Hong, Dan-Bi;Lee, Myeong-Kyu;Joo, Gene
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.33-44
    • /
    • 2003
  • This paper describes the design and analysis technology of composite flexure and composite paddle-type blade which are all key technologies on hingeless rotor system. Through replacing the existing metal or engineering plastic flexure part with composite part, Several required structural analysis were accomplished, which are static analysis by using NASTRAN and dynamic analysis by using FLIGHTLAB. The dynamic characteristics of composite hingeless hub attached with paddle-type blade was also investigated. Further more, small-scaled paddle-type blade was designed using froude scaled properties of existing full size blade. Through this design procedure of composite paddle-type blade, the structural design method was achieved. These results will be applied to accomplishing current project named as "the development of next-generation helicopter rotor system."

  • PDF

A Study on the Development and Performance Test of the Paddle-type Fluidized Dryer (패들형 유동층 건조기 상품화를 위한 기초적 연구)

  • Kum Sung-Min;Lee Kwang-Cheol;Kong Min-Seog;Yoo Byung-Hun;Lee Hyun-Gu;Lee Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.734-740
    • /
    • 2006
  • The purpose of this study is to develop and commercialize a paddle-type fluidized dryer. The drying system used in this study, was designed to attach a paddle-type fluidized mixer to a dryer. The drying system is based on the drying method to generate thermal contacts, as fluidized layers are generated due to a paddle mechanism. Accordingly, the time of drying is short and material damage is very little. Also, the drying system operates as a closer system so it can be utilized not only for food and chemical materials, but also for environmental pollution materials. According to its performance test, the drying system is possible to dry low-moisture contents and its drying performance is outstanding. In conclusion, the drying system designed for this study, is likely to have great potential for commercialization.

Flow Simulation of a $45^{\circ}$ Pitched Paddle Type Mixer ($45^{\circ}$ Pitched Paddle 형 교반기 내부 유동 해석)

  • Chang J.;Hur N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.109-114
    • /
    • 2000
  • Mechanical agitation is widely used in industrial process engineering. In the present study, peformed was a numerical simulation on flows in a $45^{\circ}$ Pitched Paddle Type mixer. Through a CFD technique, effects of the position of the impeller on resultant flow pattern was studied. Results of computed torque on impeller to maintain the flow are also compared to the experimental data, and showed good qualitative agreements.

  • PDF

Flow Patterns in a Spherical Vessel with Double-Stage Paddle Impeller (2단 패들 임펠러를 갖춘 구형교반조에서의 유동상태)

  • Lee, Young-Sei;Lee, Joon-Man
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.4
    • /
    • pp.263-269
    • /
    • 2007
  • A numerical algorithm for three-dimension laminar flow in an agitated vessel was established by using the spherical coordinates. Flow pattern for the double-stage paddle impeller was not dependent upon the distance of among the impeller in the agitated vessels. The numerical simulation of the flow pattern in spherical and cylindrical agitated vessel agree well with the visualization results.

  • PDF

Power Consumption for Double-Stage Paddle Impeller in Cylindrical and Spherical Agitated Vessels (원통 및 구형교반조에서의 2단 Paddle 임펠러에 대한 소요동력)

  • Lee, Young-Sei;Choi, Hyun-Kuk;Shida, Hirotaka
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2006
  • Power consumption for double-stage paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained which was applied to both spherical and cylindrical vessel, when the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel which had a height equal to its diameter and had the same volume as the spherical vessel. The power consumption for the double-stage impeller was dependent upon the distance of among the impeller in the agitated vessels, as follows: $$f/2={\frac{C_L}{Re_G}}+{\frac{Ct}{2}}({\frac{C_tr}{Re_g}}+Re_g)^{-m}$$

  • PDF

Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material (압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.455-460
    • /
    • 2019
  • This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

Double Paddle Pectoralis Major Myocutaneous Flap for Simultaneous Reconstruction of Oro-or Pharyngocutaneous Fistula (구강 혹은 인두피부루의 동시재건을 위한 양면 대흉근피판술)

  • Lim Young-Chang;Son Eun-Jin;Shin Woo-Chul;Kim Sang-Cheol;Lee Wook-Jin;Choi Eun-Chang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.47-51
    • /
    • 2003
  • Background and Objectives: Oro-and pharyngocutaneous fistula after irradiation can lead to extensive wound necrosis and fetal complication such as carotid rutpure. So, there is a need to clean and cover the wound rapidly in these compromised patients. Pectoralis major myocutaneous (PMMC) flap has been presented for reconstruction of complex defects in these irradiated patients. We applied the double paddle PMMC flap for the simultaneous reconstruction of above complex defects and evaluated the it's clinical efficacy. Material and Methods: Retrospective chart review of three cases of simultaneous head and neck reconstruction after irradiation with double paddle PMMC. All patients received prior radiotherpy before development of complications. The double paddle PMMC flap was used for mucosal lining of the oral cavity and epithelial lining of external skin in 2 cases, for mucosal lining of the pharynx and epithelial lining of external skin in 1 case. Results: Considerable complications such as major flap necrosis or fistula did not occur in any of the cases, and simultaneous reconstruction was achieved in all cases without reoperations. Conclusion: Many extended defects such as oro-and pharyngocutaneous fistula involving cover and lining about the head and neck after irradiation can be rehabilitated by the double paddle pectoralis major myocutaneous flap.