• Title/Summary/Keyword: pH reduction

Search Result 2,076, Processing Time 0.032 seconds

Intracellular pH is a Critical Element in Apoptosis Triggered by GM-CSF Deprivation in TF1 Cells

  • Yoon, Suk Ran;Choi, In Pyo
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.268-275
    • /
    • 2003
  • Background: Hemopoietic cells require the constant presence of growth factors for survival in vitro and in vivo. Caspases have been known as central executors of apoptotic cell death. We have, therefore, investigated the pathways that regulate caspase activity and apoptosis using the $CD34^+$ cell line, TF-1 which requires GM-CSF for survival. Methods: Apoptosis was measured by annexin V staining and mitochondrial membrane potential was measured by DiOC6 labelling. Intracellular pH was measured using pH sensitive fluorochrome, BCECF or SNARF-1, followed by flow cytometry analysis. Caspase activation was analyzed by PARP cleavage using anti-PARP antibody. Results: Removal of GM-CSF induceed PARP cleavage, a hallmark of caspase activity, concomitant with pHi acidification and a drop in mitochondrial potential. Treatment with ZVAD, a competitive inhibitor of caspases, partially rescued cell death without affecting pHi acidification and the reduction of mitochondrial potential, suggesting that both these events act upstream of caspases. Overexpression of Bcl-2 prevented cell death induced by GM-CSF deprivation as well as pHi acidification and the reduction in mitochondrial membrane potential. In parental cells maintained with GM-CSF, EIPA, a competitive inhibitor of $Na^+/H^+$ antiporter induced apoptosis, accompanied by a drastic reduction in mitochondrial potential. In contrast, EIPA induced apoptosis in Bcl-2 transfectants without causing mitochondrial membrane depolarization. Conclusion: Taken together, our results suggest that the regulation of $H^+$fluxes, either through a mitochondriondependent or independent pathway, is central to caspase activation and apoptosis.

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

Stress and Junction Leakage Current Characteristics of CVD-Tungsten (CVD 텅스텐의 응력 및 접합 누설전류 특성)

  • 이종무;최성호;이종길
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.176-182
    • /
    • 1992
  • t-Stress and junction leakage current characteristics of CVD-tungsten have been investigated. Stressversus continuous annealing temperature plot. shows hysteresis curve where the stress level of the cooling curveis higher than that of the heating curve. It is found that the thermal and intrinsic stress of tungsten film depositedby SiH4 reduction is higher than that by Hz reduction.The tungsten film deposited by SiHl reduction is in the tensile stress state below 700"Cnd the stress ofthe film decreses with increasing annealing temperature. The stress state changes into compressive stress atabout 700"Cnd the compressive stress increases rapidly with increasing temperature.Leakage current of the n+/p diode increases rapidly especially in the range of 400-450$^{\circ}$C with increasingdeposition temperature of the CVD-W by SiH4 reduction, which is due to the Si consumption by W encroachment.On the other hand leakage current of the n+/p diode slightly increases with increasing SiH4/WF6 ratio.h increasing SiH4/WF6 ratio.

  • PDF

Antimicrobial Activity of Citral against Salmonella Typhimurium and Staphylococcus aureus (살모넬라와 황색포도상구균에 대한 시트랄의 항균효과)

  • Kim, Jung-Jee;In, Ye-Won;Oh, Se-Wook
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.791-794
    • /
    • 2011
  • The aim of this study was to investigate the antimicrobial characteristics of citral against Salmonella Typhimurium and Staphylococcus aureus. Antimicrobial activities were determined according to the citral concentration and initial pH. The tested citral concentrations were 0-1,000 ppm in tryptic soy broth (TSB) and 0-5,000 ppm in Angelica keiskei juice (NokJeup). The initial pHs tested were 4-7. Antimicrobial activities increased as citral concentration increased. S. aureus was more susceptible than S. Typhimurium during culture in TSB. But S. aureus was less susceptible to pH changes. Citral caused about 1-2 log reduction of S. aureus and 2-5 log reduction of S. Typhimurium after 10 min exposure at different pHs. As the citral concentration in the Algelica keiskei juice increased, S. aureus was easily inactivated but S. Typhimurium was not inactivated.

pH Dependent Size and Size Distribution of Gold Nanoparticles

  • Kang, Aeyeon;Park, Dae Keun;Hyun, Sang Hwa;Yun, Wan Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.267.2-267.2
    • /
    • 2013
  • In the citrate reduction method of gold nanoparticle (AuNP) synthesis, pH of the reaction mixture can have a considerable impact on the size and size distribution of AuNPs. In this work, effects of pH variation upon the size and its distribution were examined systematically. As the initial pH was change from 5.5 to 10.5, it showed an optimal pH around 7.5. At this pH, both of the size and the size distribution showed their minimum values, which was verified by transmission electron microscopy and UV-vis spectroscopy. This occurrence of optimal pH was discussed with the results of in situ monitoring pH during the reaction of AuNP synthesis.

  • PDF

Sorption of Chromium Ions from Aqueous Solution onto Chemically Activated Carbons Developed from Maize Cobs

  • Youssef, A.M.;El-Nabarawy, Th.;Shouman, Mona A.;Khedr, S.A.
    • Carbon letters
    • /
    • v.9 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • Chemically activated carbons were prepared from maize cobs, using phosphoric acid of variable concentration. The textural parameters of the activated carbons were determined from the nitrogen adsorption isotherms measured at 77 K. The chemistry of the carbon surface was determined by measuring the surface pH, the pHPZC and the concentration of the carbon - oxygen groups of the acid type on the carbon surface. Kinetics of Cr(VI) sorption/reduction was investigated at 303 K. Two processes were investigated in terms of kinetics and equilibrium namely; Cr(VI) removal and chromium sorption were studied at various initial pH (1-7). Removal of Cr(VI) shows a maximum at pH 2.5. At pH<2.5, sorption decreases because of the proton competition with evolved Cr(III) for ion exchange sites. The decrease of sorption at pH>2.5 is due to proton insufficiency and to the decrease of the extent of Cr(VI) reduction. The chemistry of the surface of activated carbon is an important factor in determining its adsorption capacity from aqueous solutions particularly when the sorption process involves ion exchange.

Improvement of Virus Safety of a Human Intravenous Immunoglobulin by Low pH Incubation

  • Kim, In-Seop;Choi, Yong-Woon;Lee, Sung-Rae;Cho, Hang-Bok;Eo, Ho-Gueon;Han, Sang-Woo;Chang, Chong-Eun;Lee, Soung-Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.619-627
    • /
    • 2001
  • n order to increase the virus safety of a human intravenous immunoglobulin (IVIg) that was manufactured by a successive process of cold ethanol fractionation, polyethylene glycol precipitation, and pasteurization ($60^{\circ}C$ heat treatment for 10h), a low pH incubation process (pH 3.9 at $25{\circ}C$ for 14 days) was employed as the final step. The efficacy and mechanism of the fraction III cold ethanol fractionation, pasteurization, and low pH treatment steps in the removal and/or inactivation of blood-borne viruses were closely examined. A variety of experimental model viruses for human pathogenic viruses, including the Bovine herpes virus (BHV), Bovine viral diarrhoea virus (BVDV), Murine encephalomyocarditis virus (EMCV), and Porcine parvovirus (PPV), were selected for this study. The mechanism of reduction for the enveloped viruses (BHV and BVDV) during fraction III fractionation was both inactivation and partitioning, however, it was partitioning in the case of the nonenveloped viruses (EMCV and PPV). The log reduction factors achieved during fraction III fractionation were ${\geqq}$6.7 for BHV, ${\geqq}4.7$ for BVDV, 4.5 for EMCV, and 4.4 for PPV. Pasteurization was found to be a robust and effective step in inactivating all the viruses tested. The log reduction factors achieved during the pasteurization process were ${\geqq}7.5$ for BHV, ${\geqq}4.8$ for BVDV, 3.0 for EMCV, and 3.3 for PPV. A low pH incubation was very effective in inactivating the enveloped viruses as well as EMCV. The log reduction factors achieved during low pH incubation were ${\geqq}7.4$ for BHV, ${\geqq}3.9$ for BVDV, 5.2 for EMCV, and 2.0 for PPV. These results indicate that the low pH treatment successfully improved the viral safety of the final products.

  • PDF

Investigation of Diazepam by Pulsed Rotation Voltammetry

  • Blaedel, W.J.;Hahn, Young-Hee
    • Archives of Pharmacal Research
    • /
    • v.2 no.2
    • /
    • pp.111-114
    • /
    • 1979
  • Diazepam was investigated in aqueous buffer media using pulsed rotation voltammetry. The dependence of half-wave potentials on pH indicated a two proton involvement in a two electron transfer reduction in the pH range 3-10. Dizaepam at micromolar concentration levels may be determined by measurement of the limiting difference current.

  • PDF

Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater (Alum과 PACl을 이용한 응집처리)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

Containing Heavy Metal Contaminants Using Soil-Cement Column Barrier (심층혼합기둥체 차수벽을 이용한 중금속 오염물질의 이동 제어)

  • 정문경;천찬란;이주형;김강석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.821-826
    • /
    • 2003
  • Laboratory experiments were peformed to understand physical properties of soil-cement column under the influence of acidic flow including metal contaminants and its retaining capacity against metal migration. The contaminant used in this study was nitric acid with Cu and Cd. The Permeability of soil-cement column decreased when pH of the column began to drop below 12. Decreases in pH led to significant reduction of compressive strength of clayey soil-cement specimen, while relatively marginal reduction for sandy soil-cement specimen. The metal contaminants did not leachate from soil-cement column until pH of soil-cement dropped below 7∼8 for Cu and 9∼10 for Cd. Metal contaminants were precipitated and trapped inside the soil-cement column at pHs higher than those mentioned as verified with metal analysis and visual inspection. This indicated that soil-cement column not only performs well as a cut-off wall, but also helps alleviating the level of contamination of the surrounding environment.

  • PDF