• Title/Summary/Keyword: pH measurement test

Search Result 191, Processing Time 0.028 seconds

Analysis of Job Satisfaction among Female Dentists in Gwangju (광주지역 일부 여자치과의사의 직업만족도)

  • Choo, Hyun Hee;Cho, Jin-Hyoung;Kim, Min-Seok
    • The Journal of the Korean dental association
    • /
    • v.55 no.2
    • /
    • pp.139-155
    • /
    • 2017
  • The study of job satisfaction among female dentists is essential to improve the quality of their life. In this study, a job satisfaction survey of female dentists in Gwangju was performed and the factors affecting job satisfaction were examined. A survey of female dentists in Gwangju was conducted using a custom-designed and validated questionnaire which incorporated the Korean Dentist satisfaction Survey (KDSS) as well as questions regarding socio-demographics and professional characteristics. Satisfaction for each question was measured by a 5-point Likert scale. The final analysis was performed with 89 questionnaires, after excluding 3 non-response questionnaires. Analysis of the data for each group was carried out using a Mann-Whitney U test and Kruskal-Wallis H test. The reliability of the questionnaire was identified by the internal consistency of the survey using Cronbach coefficient. The data were statistically analyzed using SPSS (IBM SPSS Statistics 19, SPSS Inc, Chicago, Ill, USA). The level of statistical significance was set at p = 0.05. On analyzing with use of the above mentioned method, the following findings were observed: Income, leisure time, time for self-development, and overall job satisfaction were lower than the average, especially the percentage of dissatisfaction was much higher than that of satisfaction. Satisfaction was associated with age, duration of employment, and the number of assistants. The limitations of this study are the lack of an adequate sample size, convenience sampling during extraction, the lack of questionnaire items, the limitations of quantitative research, and failure to perform measurement in the non-response group. However, female dentists can be expected to achieve a more satisfactory and enhanced working environment if the research based on the current study is followed up in an expanded target group.

  • PDF

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charite$^{TM}$ in the Human Cadaveric Spine under Physiologic Compressive Follower Preload: A Comparative Study between Load Control Protocol and Hybrid Protocol

  • Kim, Se-Hoon;Chang, Ung-Kyu;Chang, Jae-Chil;Chun, Kwon-Soo;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.144-151
    • /
    • 2009
  • Objective: To compare two testing protocols for evaluating range of motion (ROM) changes in the preloaded cadaveric spines implanted with a mobile core type Charite$^{TM}$ lumbar artificial disc. Methods: Using five human cadaveric lumbosacral spines (L2-S2), baseline ROMs were measured with a bending moment of 8 Nm for all motion modes (flexion/extension, lateral bending, and axial rotation) in intact spine. The ROM was tracked using a video-based motion-capturing system. After the Charite$^{TM}$ disc was implanted at the L4-L5 level, the measurement was repeated using two different methods: 1) loading up to 8 Nm with the compressive follower preload as in testing the intact spine (Load control protocol), 2) loading in displacement control until the total ROM of L2-S2 matches that when the intact spine was loaded under load control (Hybrid protocol). The comparison between the data of each protocol was performed. Results: The ROMs of the L4-L5 arthroplasty level were increased in all test modalities (p < 0.05 in bending and rotation) under both load and hybrid protocols. At the adjacent segments, the ROMs were increased in all modes except flexion under load control protocol. Under hybrid protocol, the adjacent segments demonstrated decreased ROMs in all modalities except extension at the inferior segment. Statistical significance between load and hybrid protocols was observed during bending and rotation at the operative and adjacent levels (p< 0.05). Conclusion: In hybrid protocol, the Charite$^{TM}$ disc provided a relatively better restoration of ROM, than in the load control protocol, reproducing clinical observations in terms of motion following surgery.

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Comparison of Flavor Characteristics and Palatability of Beef Obtained from Various Breeds (품종별 쇠고기의 풍미특성과 기호성 비교)

  • Park, Hyung-Il;Lee, Moo-Ha;Chung, Myung-Sub
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.500-506
    • /
    • 1994
  • For comparison of beef quality, four kinds of beef (Korean native cattle beef, dairy cattle beef, imported beef, cross-bred beef) were investigated through tenderness, juiciness and flavor related components measurement and organoleptic tests. Flavor related chemical components such as NPN, IMP, free fatty acid and free amino acids were analyzed, water holding capacity, contents of hydroxyproline and intramuscular fat were measured for evaluation of beef tenderness. Instron was also used for measuring beef tenderness as an objective method. Triangle test and descriptive analysis test were conducted for comparison and evaluation of preference of various beef samples. In hardness analysis using Instron, imported and cross-bred beefs had higher value than that of Korean native cattle or dairy cattle beef. Water holding capacity and pH of Korean cattle beef was higher than that of others. The intramuscular fat content of Korean cattle beef was highest, so it was expected juicier than other beef. In flavor related compound analysis, NPN content of Korean native cattle beef was the lowest, which shows it spent the least time among sample meats after slaughter. IMP, hypoxantine and inosine were most abundant in Korean native cattle beef. In free amino acids analysis showed that the proportion of basic acid and aromatic acid content of Korean native cattle beef was highest, whereas that of sulfur containing amino acid of imported beef was highest. TBA value of Korean native cattle beef was the lowest, and analysis of fatty acid composition revealed that the proportion of unsaturated fatty acid of Korean native cattle beef was higher than imported and dairy cattle beef, but similar to cross-bred beef. Organoleptic test was performed by triangle test and descriptive analysis. In triangle test, most panelist could distinguish Korea native cattle beef from imported beef and cross-bred beef, imported beef from cross-bred beef. In descriptive analysis which relys on subjective standards of panelists, there was no difference among beef in aroma, flavor and tenderness except juiciness. Even though contents of non volatile flavor compounds in Korean native cattle beef were higher than those of other beef samples, there were no significant differences in subjective panel test. The results showed that Korean consumers do not have common standards for beef quality evaluation.

  • PDF

Sample pre-treatment for measurement of $^{129}$I in radwastes (방사성폐기물 중 $^{129}$I 측정을 위한 시료의 전처리)

  • Ke Chon Choi;Sun Ho Han;Jee Kwang Yong;Ki Seop Choi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Many different kinds of radwastes are discharged from the nuclear power plants, and $^{129}$I is included in these radwastes. Recovery test of $^{129}$I was evaluated for different radwastes(dry active waste, sludge, spent resin and simulated evaporator bottom). Recovery of $^{129}$I for dry active waste by acid leaching with $1.8\%$ NaClO was $74.3\%$$(RSD,\;2.2\%)$ and l291 for spent rein by alkali fusion method with KOH as a flux agent was $87.7\%$$(RSD,\;0.9\%$), respectively. iodide in simulated evaporator bottom containing a high concentration of borate was adsorbed with anion exchange resin at pH 7 phosphate buffer solution. Recovery of $^{129}$I for anion exchange resin was $92.5\%$ and not affected up to 1,200 $\mu$g/mL $H_3BO)3$(as a Boron). Recovery of $^{129}$I for the spent resin from nuclear power plant was $87.2\%$ $(RSD,\;1.2\%)$.

  • PDF

Freshness Monitoring of Raw Salmon Filet Using a Colorimetric Sensor that is Sensitive to Volatile Nitrogen Compounds (휘발성 질소화합물 감응형 색변환 센서를 활용한 연어 신선도 모니터링)

  • Kim, Jae Man;Lee, Hyeonji;Hyun, Jung-Ho;Park, Joon-Shik;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 2020
  • A colorimetric paper sensor was used to detect volatile nitrogen-containing compounds emitted from spoiled salmon filets to determine their freshness. The sensing mechanism was based on acid-base reactions between acidic pH-indicating dyes and basic volatile ammonia and amines. A sensing layer was simply fabricated by drop-casting a dye solution of bromocresol green (BCG) on a polyvinylidene fluoride substrate, and its color-change response was enhanced by optimizing the amounts of additive chemicals, such as polyethylene glycol, p-toluene sulfonic acid, and graphene oxide in the dye solution. To avoid the adverse effects of water vapor, both faces of the sensing layer were enclosed by using a polyethylene terephthalate film and a gas-permeable microporous polytetrafluoroethylene sheet, respectively. When exposed to basic gas analytes, the paper-like sensor distinctly exhibited a color change from initially yellow, then to green, and finally to blue due to the deprotonation of BCG via the Brønsted acid-base reaction. The use of ammonia analyte as a test gas confirmed that the sensing performance of the optimized sensor was reversible and excellent (detection time of < 15 min, sensitive naked-eye detection at 0.25 ppm, good selectivity to common volatile organic gases, and good stability against thermal stress). Finally, the coloration intensity of the sensor was quantified as a function of the storage time of the salmon filet at 28℃ to evaluate its usefulness in monitoring of the food freshness with the measurement of the total viable count (TVC) of microorganisms in the food. The TVC value increased from 3.2 × 105 to 3.1 × 109 cfu/g in 28 h and then became stable, whereas the sensor response abruptly changed in the first 8 h and slightly increased thereafter. This result suggests that the colorimetric response could be used as an indicator for evaluating the degree of decay of salmon induced by microorganisms.

Effects of Three Lumbar Stabilization Exercises on the Thickness of Deep and Superficial Fibers of the Lumbar Multifidus (다열근 심부 및 표면 근섬유 두께에 대한 세 가지 요추안정화 운동의 효과)

  • Kim, Su-Jung;Ha, Sung-Min;Park, Kyu-Nam;Jung, Doh-Heon;Kim, Tae-Jin;Cynn, Heon-Seock;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.19 no.2
    • /
    • pp.20-28
    • /
    • 2012
  • The lumbar multifidus muscle, which can be separated into deep fascicles (DM) and superficial fascicles (SM), is important for lumbar segmental stability. However, no previous studies have investigated the effect of lumbar stabilization exercises on the thickness of DM and SM. Thus, the purpose of this study was to assess DM thickness after three different lumbar segmental stabilization exercises. In total, 30 healthy male participants were recruited and randomly assigned to one of three exercise groups: hollowing in the quadruped position (H-Quad), contralateral arm and leg lift (CALL), and bilateral arm and leg lift (BALL). Each lumbar segmental stabilization exercise was conducted over 4 weeks. Ultrasonography was used to compare the DM and SM thickness before and after the 4 weeks of exercise. A mixed-model analysis of variance using Scheffe's post-hoc test was used for statistical analysis. The results showed a significant effect for the measurement time (before vs. after 4 weeks of exercise) in the DM (F=31.26, p<.05) and SM (F=4.56, p<.05). At the end of the 4 weeks, the DM thickness had increased significantly in the H-Quad exercise group, and the SM thickness had increased significantly in the CALL and BALL exercise groups. Also in the BALL exercise group, the SM thickness was greater compared with that in the H-Quad exercise group. These findings suggest that the thickness of the DM and SM were increased by different types of lumbar segmental stability exercise after 4 weeks.