• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.03 seconds

On-Line Real Time Soil Sensor

  • Shibusawa S.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.45-49
    • /
    • 2003
  • Achievements in the real-time soil spectro-photometer are: an improved soil penetrator to ensure a uniform soil surface under high speed conditions, real-time collecting of underground soil reflectance, getting underground soil color images, use of a RTK-GPS, and all units are arranged for compactness. With the soil spectrophotometer, field experiments were conducted in a 0.5 ha paddy field. With the original reflectance, averaging and multiple scatter correction, Kubelka-Munk (KM) transformation as soil absorption, its 1st and 2nd derivatives were calculated. When the spectra was highly correlated with the soil parameters, stepwise regression analysis was conducted. Results include the best prediction models for moisture, soil organic matter (SOM), nitrate nitrogen ($NO_3-N$), pH and electric conductivity (EC), and soil maps obtained by block kriging analysis.

  • PDF

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

Nano composite System based on ZnO-functionalized Graphene Oxide Nanosheets for Determination of Cabergoline

  • Beitollahi, Hadi;Tajik, Somayeh;Alizadeh, Reza
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • In this paper we report an electrochemical sensor based on ZnO-functionalized graphene oxide nanocomposite (ZnO-GO) for the sensitive determination of the cabergoline. Cabergoline electrochemical behaviors were investigated by cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV). The modified electrode shows electrocatalytic activity toward cabergoline oxidation in phosphate buffer solution (PBS) (pH 7.0) with a reduction of the overpotential of about 180 mV and an increase in peak current. The DPV data showed that the obtained anodic peak currents were linearly dependent on the cabergoline concentrations in the range of $1.0-200.0{\mu}M$, with the detection limit of $0.45{\mu}M$. The prepared electrode was successfully applied for the determination of cabergoline in real samples.

유전자 재조합 대장균을 이용한 5-Aminolevulinic acid(ALA)의 대량 생산 기술 및 모니터링 기술 개발

  • Jeong, Sang-Yun;Lee, Jong-Il;Scheper, Th.
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.87-90
    • /
    • 2003
  • ALA is an essential intermediate in the tetrapyrrole biosynthesis pathway and has applications as a biodegradable herbicide and insecticide as well as medical applications including photodynamic therapy of cancers. For the development of mass production process of ALA it is necessary to on-line monitor some metabolites such as glycine, succinate, LA and ALA. In this work, medium compositions, pH conditions, induction and addition of LA were investigated to increase the production of ALA by recombinant E. coli. A 2-dimensional fluorescence sensor was used to monitor the processe and the fluorescence spectra were correlated with on- and off-line data like ALAS, ALAD, cell mass etc.

  • PDF

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

Trends and Applications on Multi-beam Side Scan Sonar Sensor Technology (측면주사음탐기 센서 기술 동향 및 응용)

  • Kye, J.E.;Cho, J.I.;Yoo, W.P.;Choi, S.L.;Park, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.28 no.6
    • /
    • pp.167-179
    • /
    • 2013
  • 측면주사음탐기(side scan sonar) 센서는 해저면의 영상을 실시간으로 탐색하는 장비로서 해양탐사 및 지질조사, 해저통신 및 어초조사, 기뢰 및 잠수정 탐색 등 해양탐사와 관련한 대표적 장비라고 할 수 있다. 센서는 해저와 목표물을 표시하기 위해 소나 플랫폼의 움직임을 사용하며, 동작주파수 범위는 20kHz~500kHz이다. 이 주파수는 요구되는 깊이와 목표물의 크기에 의해서 결정된다. 센서는 수직으로 $45^{\circ}$, 수평으로 $2^{\circ}$ 정도의 신호전파 방사각도 폭을 가진다. 최근에는 해양탐사와 개발을 위해 빠른 스캔속도와 정확한 정보, 고해상도의 영상을 얻기 위해 해저면에 대한 다중빔 영상센서의 핵심기술로 활용되면서 그 활용성과 중요성이 점차 증가되고 있다. 본고에서는 측면주사소나 센서의 기본 원리 및 종류, 디중빔측면주사소나 기술동향, 응용분야의 사례를 소개함으로써, 국내 기반기술 및 상용화 개발이 취약한 측면주사 음탐기 센서에 대한 이해를 돕고자 한다.

Development of Rogowski-Coil Type CT for Application in 170kV GIS (170kV GIS용 Rogowski coil형 CT개발)

  • Chung, Y.H.;Kim, J.B.;Song, W.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF

Hydrogen sensing of Nano thin film and Nanowire structured cupric oxide deposited on SWNTs substrate: A comparison

  • Hoa, Nguyen Duc;Quy, Nguyen Van;O, Dong-Hun;Wei, Li;Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.52.1-52.1
    • /
    • 2009
  • Cupric oxide (CuO) is a p-type semiconductor with band gap of ~1.7 eV and reported to be suitable for catalysis, lithium-copper oxide electrochemical cells, and gas sensors applications. The nanoparticles, plates and nanowires of CuO were found sensing to NO2, H2S and CO. In this work, we report about the comparison about hydrogen sensing of nano thin film and nanowires structured CuO deposited on single-walled carbon nanotubes (SWNTs). The thin film and nanowires are synthesized by deposition of Cu on different substrate followed by oxidation process. Nano thin films of CuO are deposited on thermally oxidized silicon substrate, whereas nanowires are synthesized by using a porous thin film of SWNTs as substrate. The hydrogen sensing properties of synthesized materials are investigated. The results showed that nanowires cupric oxide deposited on SWNTs showed higher sensitivity to hydrogen than those of nano thin film CuO did.

  • PDF

Fabrication and Electrochemical Detection Property of Single Strand DNA Hybridization Sensor (DNA Hybridization 센서의 제작과 전기화학적 검출 특성)

  • Lee, Dong-Yun;Yang, Chang-Heon;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1375-1376
    • /
    • 2007
  • A synthesized 21-mer single-stranded DNA(ss DNA) was covalently immobilized onto a self-assembled aminoethanethiol monolayer modified gold electrode onto QCM. The covalently immobilized ssDNA was hybridized with complementary ssDNA. The interaction between surface immobilized ssDNA and complementary 21-mer DNA in solution was also examined. Each step was followed by monitoring changes in the QCM frequency with time. Also, PBS with pH 7.0 was selected as a supporting electrolyte in order to get maximum sensitivity and good bioactivity.

  • PDF