• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.031 seconds

Design of Bias Circuit for Measuring the Multi-channel ISFET (다채널 ISFET 측정용 단일 바이어스 회로의 설계)

  • Cho, Byung-Woog;Kim, Young-Jin;Kim, Chang-Soo;Choi, Pyung;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 1998
  • Multi-channel sensors can be used to increase the reliability and remove the random iloise in ion-sensitive field effect transistors(ISFETs). Multi-channel sensors is also an essential step toward potential fabrication of sensors for several ionic species in one device. However, when the multi-channel sensors are separately biased, the biasing problems become difficult, that is to say, the bias circuit is needed as many sensors. In this work, a circuit for biasing the four pH-ISFETs in null-balance method, where bias voltages are switched, was proposed. The proposed concept is need only one bias circuit for the four sensors. Therefore it has advantages of smaller size and lower power consumption than the case that all sensors are separately biased at a time. The proposed circuit was tested with discrete devices and its performance was investigated. In the recent trend, sensor systems are implemented as portable systems. So the verified measurement circuit was integrated by using the CMOS circuit. Fortunately, ISFET fabrication process can be compatible with CMOS process. Full circuit has a mask area of $660{\mu}m{\times}500{\mu}m$. In the future, this step will be used for developing the smart sensor system with ISFET.

  • PDF

Measurement of Ion Concentrations in Denitrifying Biofilm by Microelectro-sensor (미소전극 센서를 이용한 탈질 생물막내의 이온 농도측정)

  • Jang, Am;Lee, Ssang G.;Kim, S.M.;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1833-1841
    • /
    • 2000
  • Microelectrode probe was made and applied to the biofilm in the biological treatment process as the state-of-art technology in order to actually measure the biofilm thickness, ionic concentration gradient, and material transport, etc. instead of classical theoretical approach. The working microelectrode, one of the main components of microelectrode probe, was easily contaminated and broken when determining the differences in the ionic concentrations through the measurement of biofilm's EMF (electromotive force). As a demonstration, two microelectrode probes were constructed in our lab for the measurement of the pH and $NO_3{^-}$ concentration in denitrifying biofilm. The microelectrode probe through the inner biofilm ($350{\mu}m$ from the surface of biofilm) showed that the pH was increased from pH 8 in the bulk solution to pH 8.3, on the other hand, the $NO_3{^-}$ concentration was decreased from 30 fig N/L in the bulk solution to 4 fig N/L.

  • PDF

Development of HRP-modified Carbon Composite Biosensor and Electrochemical Analysis of H2O2 (Horseradish peroxidase가 변성된 탄소복합 바이오센서 개발 및 전기화학적 H2O2분석)

  • Park, Deog-Su
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.5
    • /
    • pp.571-576
    • /
    • 2012
  • A sol-gel derived carbon composite electrodes (CCEs) were fabricated by mixing horseradish peroxidase (HRP), sol of tetraethoxysilane (TESO), and graphite powder. The HRP solution was added to the sol solution of TEOS, and then graphite powder was added to this mixture. The resulting carbon ceramic network effectively encapsulated HRP and shows a catalytic reduction starting at -0.2 V for $H_2O_2$. The optimum conditions for $H_2O_2$determination have been characterized with respect to the enzyme loading ratio and pH. The linear range and detection limit of $H_2O_2$ detection were from 0.2 mM to 2.2 mM and 0.035 mM, respectively. The common electroactive interferences such as ascorbic acid, acetaminophene, and uric acid were not affected upon the response to $H_2O_2$ at the HRP biosensor due to low detection potential.

A Study on the Development of Envi-Cone Penetrometer System (지반환경조사용 환경콘 관입시스템 개발을 위한 기초연구)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.247-254
    • /
    • 1999
  • In recent years there has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation of contaminant in the ground. There are many techniques such as geophysical, drilling, sampling, and pushing techniques for investigation of contaminated ground. The most rapidly developing site characterization techniques for geoenvironmental purposes Involve direct push technology, that is, penetration tests. In this study, the envi-cone penetrometer system is developed by modification of traditional cone penetration test. The electrical resistivity sensor, pH sensor, thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective.

  • PDF

Development of Biofilter System for Ammonia Removal in Livestock Facility (축산 시설의 암모니아 가스 제거용 바이오 필터 시스템 개발)

  • 조성인;김명락;김유용;여운영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.457-464
    • /
    • 2003
  • The purpose of this study was to develop a pilot scale bio-filter system removing ammonia gas with microorganisms. The system consisted of chaff(filter medium), a blower, a temperature sensor, a moisture sensor, a solenoid valve, and a heating system. Temperature and moisture contents were controlled via a PC to provide the microorganisms with proper environment. The microorganisms used in this study were Bacillius. coagulans NLRI T-6 and Pseudononas. putida NLRI S-21 of bacilli. Performance tests were performed to evaluate gas removal rate during 20 days. The result was shown that the removal rate was high in early days and gradually dropped below 90% without injecting the microbes. However, it was shown that when injecting the microbes, the removal rate was almost 100% and pH value was maintained at between 7 and 9 during the whole twenty-day period.

An Experimental Study for the Filling Balance of the Family Mold (Family 금형의 충전 균형을 위한 실험적 연구)

  • Park H. P.;Cha B. S.;Rhee B. O.
    • Transactions of Materials Processing
    • /
    • v.15 no.1 s.82
    • /
    • pp.47-56
    • /
    • 2006
  • It is well known that the family-mold has an advantage to reduce the cost for production and mold. However, defects are frequently occurred by over packing the smaller volume cavity during molding, especially when the family-mold has a volumetric difference between two cavities. In this study, the cavity-filling imbalance was confirmed by the temperature and the pressure sensors, and a variable-runner system was developed for balancing the cavity-filling. Experiments of balancing the cavity filling was carried out in the family-mold with the variable-runner system, and balancing the cavity-filling was confirmed by changing the cross-sectional area of a runner in the variable-runner system with the temperature and pressure sensors. The influence of the injection speed to the balancing-capability of the variable-runner system was also examined in the experiment.

Development a glucose-FIA system with a fiber optic oxygen sensor

  • Sohn, Ok-Jae;Lam, Tuan-Hung;Rhee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.730-734
    • /
    • 2005
  • Flow injection analysis (FIA) system was developed to monitor glucose concentrations in biotechnological processes. A fiber optic oxygen sensor was used to determine consumption of oxygen concentration by reaction of immobilized glucose oxidase (GOD). The GOD was immobilized on VA-Epoxy carrier and integrated into FIA system. A calibration curve for glucose was obtained in the range of 0.5 $g/L{\sim}3.0$ g/L.

  • PDF

On-line Real Time Soil Sensor

  • Shibusawa, S.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • Achievements in the real-time soil spectro-photometer are: an improved soil penetrator to ensure a uniform soil surface under high speed conditions, real-time collecting of underground soil reflectance, getting underground soil color images, use of a RTK-GPS, and all units are arranged for compactness. With the soil spectrophotometer, field experiments were conducted in a 0.5 ha paddy field. With the original reflectance, averaging and multiple scatter correction, Kubelka-Munk (KM) transformation as soil absorption, its 1st and 2nd derivatives were calculated. When the spectra was highly correlated with the soil parameters, stepwise regression analysis was conducted. Results include the best prediction models for moisture, soil organic matter (SOM), nitrate nitrogen (NO$_3$-N), pH and electric conductivity (EC), and soil maps obtained by block kriging analysis.

  • PDF

An experimental study for the filling balance of the family mold (Family 금형의 충전 밸런스를 위한 실험적 연구)

  • Cha B. S.;Rhee B. O.;Park H. P.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.132-140
    • /
    • 2005
  • It is well known that the family-mold has an advantage to reduce the cost for production and mold. However, defects are frequently occurred by over packing the smaller volume cavity during molding, especially whorl the family-mold has a volumetric difference between two cavities. In this study, we confirmed the cavity-filling imbalance by the temperature and the pressure sensors, and developed a variable-runner system for the cavity-filling balance. We carried out experiments fur balancing the cavity filling in the family-mold with the variable-runner system, and confirmed a balanced cavity-filing through analyzing the temperature and pressure change in each cavity as the cross-sectional area of the runner changed. We also examined the influence of the injection-speed to the balancing-capability of the variable-runner system in the experiment.

  • PDF

Study on current control loop error MPPT controller using the power balance/unbalance boundary point control (전력 평형/불평형 경계점 제어를 이용한 전류제어루프에러 MPPT제어기에 관한 연구)

  • Kang, T.K.;Koh, K.H.;No, S.S.;Kang, J.S.;Lee, J.Y.;Woo, J.I.;Lee, H.W.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.292-297
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF