• Title/Summary/Keyword: pH센서

Search Result 348, Processing Time 0.031 seconds

A study on the oil transformer diagnostic technology using injection type UHF PD sensor (주입식 UHF PD 센서를 이용한 유입식 변압기 진단 기술 연구)

  • Kang, W.J.;Lee, C.J.;Kang, Y.S.;Park, J.B.;Lee, H.C.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1891-1893
    • /
    • 2004
  • 이 논무에서는 유입식 변압를 대상으로 UHF 대역의 펄스신호를 검출하는 센서를 소개하고, 이를 이용한 방전 결함별 측정 결과를 소개한다. 측정결과는 기존의 PRPD법과 주파수 Domain과 위상 Domain에 대한 정보를 가지는 p-f-q 분석으로 측정 하였으며, 본 논문에서는 후자의 결과를 중심으로 서술 하였다.

  • PDF

Development of Glucose Biosensor Using Sol-Gel Reaction of Tetraethoxysilane (Tetraethoxysilane의 졸-겔 반응을 이용한 전기화학적 glucose biosenor 개발)

  • Chang, Seong-Cheol;Park, Deog-Su
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.311-317
    • /
    • 2012
  • Disposable amperometric screen-printed biosensor strips have been fabricated by a sol-gel encapsulation for the analysis of glucose. The glucose oxidase(GOx) is entrapped in the gel matrix through sol-gel transition of tetraethoxysliane(TEOS). The biosensor is fabricated by GOx containing thin film of TEOS gel on the surface of screen-printed carbon electrode(SPCE). The GOx-containing thin film of TEOS gel offers a one-step modification process on the surface of SPCE. The optimum conditions for glucose determination have been characterized with respect to the applied potential, enzyme loading ratio, and pH. The linear range and detection limit of glucose detection were from 2.0 mM to 16.0 mM and 0.25 mM, respectively.

Low temperature-operating NiO-CoO butane gas sensors

  • Jung, Dong-Ho;Choi, Soon-Don;Min, Bong-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.303-307
    • /
    • 2008
  • $NiO,\;Cu_2O,\;Mn_2O_3$ and $Cr_2O_3$ as p-type semiconductors were added in CoO with 15 wt.% ethylene glycol binder and measured the butane gas sensing characteristics. The highest sensitivity is obtained for the NiO-CoO sensors. CoO-20 at.% NiO sensor with 15 wt.% ethylene glycol binder sintered at $1100^{\circ}C$ for 24 h exhibits high sensitivity of 90 % to 5000 ppm butane gas at the sensor temperature of $250^{\circ}C$, compared to low sensitivities at the low operating temperature for commercial sensors. Response and recovery times are, respectively, within few seconds and 1min in the static flow system, indicating rapid adsorption and desorption of butane gas on sensor surface even at this low temperature.

Development a glucose-FIA system with a fiber optic oxygen sensor

  • Sohn, Ok-Jae;Lam, Tuan-Hung;Rhee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.730-734
    • /
    • 2005
  • Flow injection analysis (FIA) system was developed to monitor glucose concentrations in biotechnological processes. A fiber optic oxygen sensor was used to determine consumption of oxygen concentration by reaction of immobilized glucose oxidase (GOD). The GOD was immobilized on VA-Epoxy carrier and integrated into FIA system. A calibration curve for glucose was obtained in the range of 0.5 $g/L{\sim}3.0$ g/L.

  • PDF

Optimum Parameter Design for Defibrillator (제세동기 최적 파라미터 설계)

  • Yoon, H.Y.;Ko, H.W.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.245-251
    • /
    • 1997
  • In designing defibrillator, several parameters such as patient's transthoracic impedance, output energy level, peak current, and time duration of current waveform must be considered to generate optimum electrical shocks on the heart. Patient's transthoracic impendence depends on the physical and health condition of patient. In this study, before the development of a defibrillator, the range of above parameters value as circuit elements was determined to derive optimal waveform by predicting and analyzing the performance of designed circuit by means of simulation with the software, P-Spice. The efficiency of parameter design was verified through the performance test with the developed defibrillator.

  • PDF

TCE, PCE 측정을 위한 바이오센서의 특성

  • 류두현;김용미;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.388-391
    • /
    • 2004
  • A sol-gel fiber-optic biosensor with encapsulated pH-sensitive fluorophore and immobilized genetically modified toluene-o-xylene monooxygenase was developed to detect TCE and PCE, which are carcinogenic chlorinate organic compounds prevailing in ground water. The sensitivity was characterized for the composition of sol-gel, and manufacturing procedure. The intensity curve reveals a linear range of intensity for pollutant concentration range of 0.01ppm and 1ppm. The change in intensity was appeared to be larger at each of L for same condition, and, therefore, the wavelength of λ was chosen for the analytical measurement.

  • PDF

A Study on the Development Trends of Automobile-IT Convergence (국내외 자동차-IT 융합 추진동향)

  • Chun, H.W.;Heo, P.S.
    • Electronics and Telecommunications Trends
    • /
    • v.24 no.2
    • /
    • pp.9-18
    • /
    • 2009
  • 자동차-IT 융합은 첨단 IT 신기술을 기반으로 자동차의 센서 및 전자장치가 지능적, 유기적으로 상호 작용하여 운전자의 안전 및 편의성을 증대시켜 최적의 운전환경을 제공한다. 미래형 자동차 산업에 부가가치를 창출하는 산업으로, 안전과 편리성의 고도화를 중심으로 빠르게 확산되고 있다. 본 고에서는 국내외 자동차업체 및 IT 업체들의 추진동향을 중심으로 살펴보고 정책적 시사점을 도출하고자 한다.

Photolithographic Formation of GOD Immobilized Membranes for ISFET Glucose Sensors (ISFET 포도당센서를 위한 GOD 고정화막의 사진식각 형성법)

  • 김창수;최성문;서화일;김의락;손병기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.58-63
    • /
    • 1992
  • Photolithography techniques were applied for immobilization of GOD membrane on the pH-ISFET with photo-sensitive polymers to realize ISEFT glucose sensor. This IC technology-compatible glucose sensor showed good sensing characteristics in the wide range of 10-1000 mg/dl glucose concentrations.

  • PDF

A Water Quality Control Model using Sensor System (센서 시스템을 이용한 수질 제어 모델)

  • Seo, Shin-Bae;Choi, Kyu-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.455-456
    • /
    • 2007
  • Nowaday it is main issues for us to protect from the polluted water which is flowing in streams and rivers simultaneously. This paper proposed a water maintenance control system using pH sensor. Also the work enables water analysis downloading VHDL coding to FPGA through Max+plus II simulation tool for display realization.

  • PDF