• Title/Summary/Keyword: p-type Ge

Search Result 91, Processing Time 0.028 seconds

Si-core/SiGe-shell channel nanowire FET for sub-10-nm logic technology in the THz regime

  • Yu, Eunseon;Son, Baegmo;Kam, Byungmin;Joh, Yong Sang;Park, Sangjoon;Lee, Won-Jun;Jung, Jongwan;Cho, Seongjae
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.829-837
    • /
    • 2019
  • The p-type nanowire field-effect transistor (FET) with a SiGe shell channel on a Si core is optimally designed and characterized using in-depth technology computer-aided design (TCAD) with quantum models for sub-10-nm advanced logic technology. SiGe is adopted as the material for the ultrathin shell channel owing to its two primary merits of high hole mobility and strong Si compatibility. The SiGe shell can effectively confine the hole because of the large valence-band offset (VBO) between the Si core and the SiGe channel arranged in the radial direction. The proposed device is optimized in terms of the Ge shell channel thickness, Ge fraction in the SiGe channel, and the channel length (Lg) by examining a set of primary DC and AC parameters. The cutoff frequency (fT) and maximum oscillation frequency (fmax) of the proposed device were determined to be 440.0 and 753.9 GHz when Lg is 5 nm, respectively, with an intrinsic delay time (τ) of 3.14 ps. The proposed SiGe-shell channel p-type nanowire FET has demonstrated a strong potential for low-power and high-speed applications in 10-nm-and-beyond complementary metal-oxide-semiconductor (CMOS) technology.

Association Between Gastric Emptying Time and Incidence of Cardiovascular Diseases in Subjects With Diabetes

  • Park, Hyung-Min;Park, Seon-Young;Chung, Jin Ook;Cho, Dong Hyuk;Park, Chang-Hwan;Kim, Hyun-Soo;Chung, Dong Jin;Choi, Sung-Kyu;Rew, Jong-Sun;Chung, Min Young
    • Journal of Neurogastroenterology and Motility
    • /
    • v.25 no.3
    • /
    • pp.387-393
    • /
    • 2019
  • Background/Aims Delayed gastric emptying (GE) is associated with high morbidity and mortality in subjects with diabetes. The aim of this study is to investigate associations between GE time and the major cardiovascular events (coronary heart diseases and ischemic stroke) in diabetic subjects with upper gastrointestinal (UGI) symptoms. Methods Among 259 subjects with chronic UGI symptoms who underwent gastric emptying study (GES) over 13 years, 122 diabetic subjects without gastric surgery and/or rapid GE were enrolled in this study. We also gathered data about baseline demographics, clinical characteristics, estimated GE half-time (GE T½) and incidence of cardiovascular events following GES. Results The mean age of subjects was 64.0 ± 17.4 years. There were 86 women and 104 subjects with type 2 diabetes. There were 52 (42.6%) subjects with normal GE, 50 (41.0.%) subjects with mild delayed GE, and 20 (16.4%) subjects with marked delayed GE. During follow-up (median, 207 weeks), cardiovascular events occurred in 7 (13.5%) subjects with normal GE, 4 (8.0%) subjects with mild delayed GE and 7 (35.0%) subjects with marked GE (P = 0.015). Univariate analysis showed that GE T½ was significantly associated with incidence of cardiovascular events (crude OR, 1.74; 95% CI, 1.12-2.69; P = 0.014). In a multivariate model, association between GE T½ and incidence of cardiovascular events remained statistically significant after adjustment for baseline characteristics and comorbidities (adjusted OR, 1.94; 95% CI, 1.21-3.12; P = 0.006). Conclusion A delay of GE was associated with an increased incidence of cardiovascular events in diabetic subjects with chronic UGI symptoms.

MgFe$_2$/GeO$_2$ AR Coating on o-type(100) Cz Silicon Solar Cells

  • Lim, D.G.;Lee, I.;Lee, U.J.;Yi, J.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.11-15
    • /
    • 2000
  • This paper presents a process optimization of antireflection (AR) coating on crystalline Si solar cells. Theoretical and experimental investigations were performed on a double-layer AR(DLAR) coating of MgFe$_2$/GeO$_2$. We investigated GeO$_2$ films as an AR layer because they have a proper refractive index of 2.46 and demonstrate the same lattice constant as Si substrate. RF sputter grown GeO$_2$ film showed deposition temperature strong dependence. The GeO$_2$ at 400$\^{C}$ exhibited a strong (111) preferred orientation and the lowest surface roughness of 6.87 $\AA$. Refractive index of MgFe$_2$film was measured as 1.386 for the most of growth temperature. An optimized DLAR coating showed a reflectance as low as 2.04% in the wavelengths ranged from 0.4 ㎛ to 1.1 ㎛. Solar cells with a structure of MgFe$_2$/GeO$_2$/Ag/N$\^$+//p-type Si/P$\^$+//Al were investigated with the without DLAR coatings. We achieved the efficiency of solar cells greater than 15% with 3.12% improvement with DLAR coatings. Further details about MgFe$_2$,GeO$_2$ films, and cell fabrication parameters are presented in this paper.

  • PDF

Output Property of Ge-Thermopile Sensor (Ge계 열전센서의 출력특성)

  • Park, Su-Dong;Kim, Bong-Seo;Oh, Min-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.265-266
    • /
    • 2006
  • It was well known that thermopile was quiet a competent sensor using to probe the temperature of "hot point" where the temperature can be off the temperature-limitation for normal operation of the main electrical power equipment. In the present work, we aimed for developing new Ge-thermopile materials which can be using a non-contact temperature sensors at various hot-point of the power equipment and evaluation of its output property. As a results of the present works, a new thermopile which were composed Ga-poded p-type and Sb-doped n-type in Ge-semiconductor were designed and manufactured by MBE(Molecular Beam Epitaxy) process and showed superior sensitivity at room temperature.

  • PDF

Ge Crystal Growth on Si Substrate for GaAs/Ge/Si Structure by Plasma-Asisted Epitaxy (GaAs/Ge/Si 구조를 위하여 PAE법을 이용한 Si 기판위에 Ge결정성장)

  • 박상준;박명기;최시영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1672-1678
    • /
    • 1989
  • Major problems preventing the device-quality GaAs/Si heterostructure are the lattice mismatch of about 4% and difference in thermal expansion coefficient by a factor of 2.64 between Si and GaAs. Ge is a good candidate for the buffer layer because its lattice parameter and thermal expansion coefficient are almost the same as those of GaAs. As a first step toward developing heterostructure such as GaAs/Ge/Si entirely by a home-built PAE (plasma-assisted epitaxy), Ge films have been deposited on p-type Si (100)substrate by the plasma assisted evaporation of solid Ge source. The characteristics of these Ge/Si heterostructure were determined by X-ray diffraction, SEM and Auge electron spectroscope. PAE system has been successfully applied to quality-good Ge layer on Si substrate at relatively low temperature. Furthermore, this system can remove the native oxide(SiO2) on Si substrate with in-situ cleaning procedure. Ge layer grown on Si substrate by PAE at substrate temperature of 450\ulcorner in hydrogen partial pressure of 10mTorr was expected with a good buffer layer for GaAs/Ge/Si heterostructure.

  • PDF

Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction (CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정)

  • Choi, Joon-Young;Woo, Sang-Keun;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • Purpose: It was reported that CT-based measured attenuation correction (CT-MAC) produced radioactivity concentration values significantly higher than $^{68}Ge$-based segmented attenuation correction (Ge-SAC) in PET images. However, it was unknown whether the radioactivity concentration difference resulted from different sources (CT vs. Ge) or types (MAC vs. SAC) of attenuation correction (AC). We evaluated the influences of the source and type of AC on the radioactivity concentration differences between reconstructed PET images in normal subjects and patients. Material and Methods: Five normal subjects and 35 patients with a known or suspected cancer underwent $^{18}F-FDG$ PET/CT. In each subject, attenuation corrected PET images using OSEM algorithm (28 subsets, 2 iterations) were reconstructed by 4 methods: CT-MAC, CT-SAC, Ge-MAC, and Ge-SAC. The physiological uptake in normal subjects and pathological uptake in patients were quantitatively compared between the PET images according to the source and type of AC. Results: The SUVs of physiological uptake measured in CT-MAC PET images were significantly higher than other 3 differently corrected PET images. Maximum SUVs of the 145 foci with abnormal FDG uptake in CT-MAC images were significantly highest among 4 differently corrected PET images with a difference of 2.4% to 5.1% (p<0.001). The SUVs of pathological uptake in Ge-MAC images were significantly higher than those in CT-SAC and Ge-MAC PET images (p<0.001). Conclusion: Quantitative radioactivity values were highest in CT-MAC PET images. The adoption of MAC may make a more contribution than the adoption of CT attenuation map to such differences.

Characterization of n-type In3Sb1Te2 and p-type Ge2Sb2Te5 Thin Films for Thermoelectric Generators (박막 열전 발전 소자를 위한 In3Sb1Te2와 Ge2Sb2Te5 박막의 열전 특성에 관한 연구)

  • Kang, So-Hyeon;Seo, Hye-Ji;Yoon, Soon-Gil
    • Korean Journal of Materials Research
    • /
    • v.27 no.2
    • /
    • pp.89-93
    • /
    • 2017
  • A thin film thermoelectric generator that consisted of 5 p/n pairs was fabricated with $1{\mu}m$-thick n-type $In_3Sb_1Te_2$ and p-type $Ge_2Sb_2Te_5$ deposited via radio frequency magnetron sputtering. First, $1{\mu}m$-thick GST and IST thin films were deposited at $250^{\circ}C$ and room temperature, respectively, via radio-frequency sputtering; these films were annealed from 250 to $450^{\circ}C$ via rapid thermal annealing. The optimal power factor was found at an annealing temperature of $400^{\circ}C$ for 10 min. To demonstrate thermoelectric generation, we measured the output voltage and estimated the maximum power of the n-IST/p-GST generator by imposing a temperature difference between the hot and cold junctions. The maximum output voltage and the estimated maximum power of the $1{\mu}m$-thick n-IST/p-GST TE generators are approximately 17.1 mV and 5.1 nW at ${\Delta}T=12K$, respectively.

Reliability Analysis of SiGe pMOSFETs Formed on PD-SOI (PD-SOI기판에 제작된 SiGe p-MOSFET의 신뢰성 분석)

  • Choi, Sang-Sik;Choi, A-Ram;Kim, Jae-Yeon;Yang, Jeon-Wook;Han, Tae-Hyun;Cho, Deok-Ho;Hwang, Young-Woo;Shim, Kyu-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.533-533
    • /
    • 2007
  • The stress effect of SiGe p-type metal oxide semiconductors field effect transistors(MOSFETs) has been investigated to compare device properties using Si bulk and partially depleted silicon on insulator(PD SOI). The electrical properties in SiGe PD SOI presented enhancements in subthreshold slope and drain induced barrier lowering in comparison to SiGe bulk. The reliability of gate oxides on bulk Si and PD SOI has been evaluated using constant voltage stressing to investigate their breakdown (~ 8.5 V) characteristics. Gate leakage was monitored as a function of voltage stressing time to understand the breakdown phenomena for both structures. Stress induced leakage currents are obtained from I-V measurements at specified stress intervals. The 1/f noise was observed to follow the typical $1/f^{\gamma}$ (${\gamma}\;=\;1$) in SiGe bulk devices, but the abnormal behavior ${\gamma}\;=\;2$ in SiGe PD SOI. The difference of noise frequency exponent is mainly attributed to traps at silicon oxide interfaces. We will discuss stress induced instability in conjunction with the 1/f noise characteristics in detail.

  • PDF

HVCVD를 이용한 다결정 SiGe 박막의 증착 및 활성화 메카니즘 분석

  • 강성관;고대홍;전인규;양두영;안태항
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.66-66
    • /
    • 1999
  • 최근 들어 다결정 SiGe은 MOS(Metal-Oxide-Semiconductor)에서 기존에 사용되던 다결정 Si 공정과의 호환성 및 여러 장점으로 인하여 다결정 Si 대안으로 많은 연구가 진행되고 있다. 고농도로 도핑된 P type의 다결정 SiGe은 Ge의 함량에 따른 일함수의 조절과 낮은 비저항으로 submicrometer CMOS 공정에서 게이트 전극으로 이용하려는 연구가 진행되고 있으며, 55$0^{\circ}C$ 이하의 낮은 온도에서도 증착이 가능하고, 도펀트의 활성화도가 높아서 TFT(Thin Film Transistor)에서도 유용한 재료로 검토되고 있다. 현재까지 다결정 SiGe의 증착은 MBE, APCVD, RECVD. HV/LPCVD 등 다양한 방법으로 이루어지고 있다. 이중 HV/LPCVD 방법을 이용한 증착은 반도체 공정에서 게이트 전극, 유전체, 금속화 공정 등 다양한 공정에서 사용되고 있는 방법으로 현재 사용되고 있는 반도체 공정과의 호환성의 장점으로 다결정 SiGe 게이트 전극의 증착 공정에 적합하다고 할 수 있다. 본 연구에서는 HV/LPCVD 방법을 이용하여 게이트 전극으로의 활용을 위한 다결정 SiGe의 증착 메카니즘을 분석하고 Ex-situ implantation 후 열처리에 따라 나타나는 활성화 정도를 분석하였다. 도펀트를 첨가하지 않은 다결정 SiGe을 주성엔지니어링의 EUREKA 2000 장비를 이용하여, 1000$\AA$의 열산화막이 덮혀있는 8 in 웨이퍼에 증착하였다. 증착 온도는 55$0^{\circ}C$에서 6$25^{\circ}C$까지 변화를 주었으며, 증착압력은 1mtorr-4mtorr로 유지하였다. 낮은 증착압력으로 인한 증착속도의 감소를 방지하기 위하여 Si source로서 Si2H6를 사용하였으며, Ge의 Source는 수소로 희석된 10% GeH4와 100% GeH4를 사용하였다. 증착된 다결정 SiGe의 Ge 함량은 RBS, XPS로 분석하였으며, 증착된 박막의 두께는 Nanospec과 SEM으로 관찰하였다. 또한 Ge 함량 변화에 따른 morphology 관찰과 변화 관찰을 위하여 AFM, SEM, XRD를 이용하였으며, 이온주입후 열처리 온도에 따른 활성화 정도의 관찰을 위하여 4-point probe와 Hall measurement를 이용하였다. 증착된 다결정 SiGe의 두게를 nanospec과 SEM으로 분석한 결과 Gem이 함량이 적을 때는 높은 온도에서의 증착이 더 빠른 증착속도를 나타내었지만, Ge의 함량이 30% 되었을 때는 온도에 관계없이 일정한 것으로 나타났다. XRD 분석을 한 결과 Peak의 위치가 순수한 Si과 순수한 Ge 사이에 존재하는 것으로 나타났으며, ge 함량이 많아짐에 따라 순수한 Ge쪽으로 옮겨가는 경향을 보였다. SEM, ASFM으로 증착한 다결정 SiGe의 morphology 관찰결과 Ge 함량이 높은 박막의 입계가 다결정 Si의 입계에 비해 훨씬 큰 것으로 나타났으며 근 값도 증가하는 것으로 나타났다.

  • PDF

Screening and broadening effects on the mobilities for p-type Si and Ge (Screening 현상 및 broadening 현상이 p형 Si과 Ge의 이동도에 미치는 효과)

  • 전상국
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.581-588
    • /
    • 1997
  • The ionization energy and degree of ionization for Si and Ge with boron doping are calculated. The hole mobilities are then calculated as a function of doping concentration using the relaxation time approximation. When the screening effect is taken into account, the reduction of ionization energy results in the increase of degree of ionization. As a result, the calculated Si mobility becomes closer to the experimental data, whereas the calculated Ge mobility is almost independent of the screening effect. The inclusion of the broadening effect in the mobility calculation overestimates the ionized impurity scattering. As compared with the experiment, the screening effect is not avoidable to calculate Si and Ge mobilities, and the broadening effect must accompany with the hopping process.

  • PDF