• Title/Summary/Keyword: p-stack

Search Result 122, Processing Time 0.029 seconds

NEIGHBORHOOD SPACES AND P-STACK CONVERGENCE SPACES

  • Park, Sang-Ho
    • East Asian mathematical journal
    • /
    • v.21 no.1
    • /
    • pp.27-39
    • /
    • 2005
  • We will define p-stack convergence spaces and show that each neighborhood structure is uniquely determined by p-stack convergence structure. Also, we will show that p-stack convergence spaces are a generalization of neighborhood spaces.

  • PDF

Analysis and Experiment of Heat Conduction and Heat Pumping in a Thermo-Acoustic Refrigerator Stack (열음향 냉동기 스택에서의 열전도와 열펌핑의 해석 및 실험)

  • Ku, B.K.;Song, T.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.473-487
    • /
    • 1995
  • A loud speaker-driven zero-c.o.p. thermoacoustic refrigerator where an automotive catalytic converter is utilized as a stack has been fabricated and investigated experimentally. Without any heat exchangers at both ends of stack(and thus with zero c. o. p.), temperatures on the stack are measured and various heat transfer rates are calculated from the measured temperatures. Temperatures on the stack have been also calculated numerically using a finite difference method. The measured temperatures are in fair agreement with the calculated temperatures for lower frequency than 300Hz, however, the former deviates from the latter considerably for higher frequency. Two types of c. o. p. have been defined as appropriate to the experiment. While the nominal c. o. p. is zero(the condition in which the pumped heat flow rate in the pore exactly cancels the axial heat conduction down the stack), the true c. o. p. is found to be about 0.14 for 300Hz from the experiments.

  • PDF

Comments on "Air Quality Impact Analysis of Point and Area Sources" ("점오염원과 면오염원의 대기환경영향 분석"에 대하여)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.255-256
    • /
    • 1993
  • Recently, Ghim and Son (1993) compared the air quality impacts of two point sources P1 and P3 in Seoul in the first quarter of 1988, whose emission rates were 99.9g/s and 49.4g/s, and whose stack heights were 75m and 21m. They said that higher concentrations from P3 in the nearby area were responsible for shorter stack height of P3. But concentrations were not raised so high only because the stack height was reduced from 75m to 21m. Volume of exit gas from P3 was also much smaller than that from P1.

  • PDF

Study on Environmental Monitoring in Stack Room for Paper Storage Using the Preservation Index (보존 환경 평가 지수를 이용한 종이 보존 서고 환경 모니터링 연구)

  • Shin, Hyun-Chang;Yoon, Man-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.61-74
    • /
    • 2011
  • Critical environmental elements for long term preservation of a paper are temperature, humidity, dust, light, contaminants in air, and mold. Especially, temperature and humidity need special care, because they can not only directly degrade paper but also affect the degradation of the other elements. Therefore methods to monitor variation of temperature and relative humidity were studied. One of the methods was to use preservation index for evaluating preservation environment. Since the evaluation for preservation environment of a stack room investigated firstly by D. K. Sebera, PI(preservation index) and TWPI(Time-Weighted Preservation Index) by IPI is made to evaluate relatively preservation environment in a stack room. T. Padfield developed method which could calculate easy PI and TWPI. In this study, the preservation environment of stack rooms for paper storage in NAK(National Archives Korea) was evaluated by PI and TWPI. PI and TWPI of stack rooms for paper storage in NAK maintained good condition but PI depended on season. Then the preservation environment of stack rooms for paper storage in NAK was required to maintain continuously PI and TWPI regardless of season change.

Pressure Distribution Simulation on Geometrical Manifolds Structure for Fabrication of a Planar-type Fuel-Cell Stack (평판형 연료전지 스택의 제조를 위한 매니폴드 형상별 압력분포 시뮬레이션)

  • Park, Se-Joon;Choi, Young-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.609-614
    • /
    • 2009
  • A fuel-cell power system among various alternative power sources has many advantages such as comparatively independable circumstances, high-efficient, and heat-recyclable, thus it is now able to be up to hundreds MWh-scaled through improving feasibility and longevity of it. During the last few decades, numerous research results has been investigated to expand interest in fuel-cell technology. This study presents pressure distribution on the geometrical manifold structures, which are U-type and Z-type, of a planar-type fuel-cell stack by simulated with computational fluid dynamics(CFD). Then, electrical performance of a 200W fuel-cell stack, which is U-type, was diagnosed after pre-conditioning operation. The stack has electrical characteristics ; 22V, 10A, 220W, and current density $200mA/cm^2$.

Electrodialysis with a channeled stack for high strength cadmium removal from wastewater

  • Kyung Jin, Min;Hyo Jin, An;Ah Hyun, Lee;Hyun-Gon, Shin;Ki Young, Park
    • Membrane and Water Treatment
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • In this study, high concentrations of cadmium-containing wastewater were treated by electrodialysis (ED) with a channel stack. The limiting current density (LCD), cadmium removal efficiency, and current efficiency were investigated under each experimental condition according to the Reynolds number (Re), membrane area, and pH. With the increase in the film area to 111, 333, 555, and 777 cm2 at Re (109.1), LCDs decreased to 408.11, 44.45, 35.32, and 13.64 A/m2, respectively. The highest cadmium removal efficiency (99.6%) and current efficiency were obtained for the membrane area of 111 and 777 cm2, respectively. Under changing Re in the pH range of 1 to 4, Re and LCD were proportional under the same pH condition, and pH and LCD tended to be inversely proportional under the same Re condition. Cadmium removal rate was the best at the pH range 3 - 4. It has been found that ED with channeled stacks can be successfully applied to treat wastewater containing high concentrations of cadmium.

Nonvolatile memory devices with oxide-nitride-oxynitride stack structure for system on panel of mobile flat panel display

  • Jung, Sung-Wook;Choi, Byeong-Deog;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.911-913
    • /
    • 2008
  • In this work, nonvolatile memory (NVM) devices for system on panel of flat panel display (FPD) were fabricated using low temperature polycrystalline silicon (LTPS) thin film transistor (TFT) technology with an oxide-nitride-oxynitride (ONOn) stack structure on glass. The results demonstrate that the NVM devices fabricated using the ONOn stack structure on glass have suitable switching characteristics for data storage with a low operating voltage, a threshold voltage window of more than 1.8 V between the programming and erasing (P/E) states after 10 years and its initial threshold voltage window (${\Delta}V_{TH}$) after $10^5$ P/E cycles.

  • PDF

Ethylene Production of Packaged Apples under Vibration Stress in Simulated Transportation Environment

  • Jung, Hyun-Mo;You, Young-Ok
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.2
    • /
    • pp.97-101
    • /
    • 2017
  • Fruits are subjected to a variety of vibration stress during the transportation from a production area to markets. Vibration inputs are transmitted from the transporting vehicle through the packaged fruit. And the steady state vibration input may cause serious internal damage of fruit. Product quality of fruits declines by various factors while they are stored right after harvesting and among the substance in charge of post ripening action, ethylene ($C_2H_4$) biosynthesis increases fruits' respiration process after harvesting and decreases storage expectancy. Ethylene production of apples rapidly increases while storage duration becomes longer. This tendency is much clearer for the apples with vibration stress at input acceleration level. When there was no vibration stress, change in ethylene production level of apples are not very large during storage. Ethylene production rates inside the gas collecting container increased significantly ($p{\leq}0.05$) after 24 hours storage, particularly for apples with vibration stress ($0.7{\mu}l/kg{\cdot}hr$ (1st stack), $0.78{\mu}l/kg{\cdot}hr$ (2nd stack), $0.96{\mu}l/kg{\cdot}hr$ (3rd stack)); whereas less ethylene was produced in control apples ($0.18{\mu}l/kg{\cdot}hr$ during storage. Also ethylene production rates of apples according to the stack position were significantly different ($p{\leq}0.05$). The vibration stress clearly accelerated the degradation of apple quality during storage, resulting in increased ethylene production.

A Study on ESD Protection Circuit for 2-Stack Structure Design Based on LVTSCR (LVTSCR 기반의 2-Stack 구조 설계를 위한 ESD 보호회로에 관한 연구)

  • Seo, Jeong-Yun;Do, Kyoung-Il;Chae, Hee-Guk;Seo, Jeong-Ju;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.836-841
    • /
    • 2018
  • In this paper, This paper is based on the conventional ESD protection circuits SCR and LVTSCR. Also, the SCR-based ESD protection circuit, which is different from the conventional structure, is presented and tested for variations in the trigger voltage and holding voltage. Due to the insertion of additional N +, P + regions, the newly added SCR-based protection circuit have improved electrical characteristics. To discuss the electrical characteristics of the proposed circuit, Synopsys T-CAD simulation data was shown.

Electrical Performance Characteristics of 200W PEM-Type Fuel Cells with Variations on Mass Flow Rate and Stack Temperature (공급유량 및 스택온도의 변이에 따른 200W급 PEM형 연료전지의 전기적 성능특성)

  • Hong, Kyung-Jin;Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.563-567
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are 1~8L/min on $H_2$ volume and $20{\sim}70^{\circ}C$ on stack temperature.