• Title/Summary/Keyword: p-p method

Search Result 22,921, Processing Time 0.04 seconds

An Experimental Study on Flexural Behavior in Framed Structure of P.S.T Method (P.S.T 공법 라멘 구조물의 휨 거동 특성에 관한 실험적 연구)

  • Cui, Jie;Yoon, Jong Nam;Eum, Ki Young;Hong, Sung Nam;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.144-152
    • /
    • 2011
  • The existing underground trenchless methods use reinforcing rod in steel tube to obtain structural stiffness. However, there are some problems such as inconvenience of work and expensive material fee which are resulted from limited working space and reinforcing work. To resolve these problems, a new trenchless method, namely P.S.T method (Prestressed Segment Tunnel Method), is developed which uses joint to connect the steel segment and form erection structure in underground construction. Further, installing strands for prestressing. In order to evaluate the flexural capacity of the P.S.T method structure, experiment was conducted. The parameters considered in the experiment are the span-to-depth ratio, diameter of steel tube at corner, prestressing force and welding of joint. Altogether examining the flexural behavior, the effect of deflection in structure according to different parameters has also been analysised.

Study on pH Reducing Method of Recycled Fine Aggregate for Embanking or Covering (성복토용 순환잔골재의 pH 저감방법에 관한 연구)

  • Han, Min-Cheol;Han, Dongyeop
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • The aim of the research is to suggest an economical and sustainable method of reducing pH of recycled aggregate as an embanking and a covering materials. Because of the unhydrated cement based materials on the surface of the recycled aggregate, it causes a severe problem on environment with leaked high alkali water from embankment and covering by using recycled aggregate. In this research, to reduce the pH of recycled aggregate, regarding the recycled fine aggregate, eight different methods were tested and analyzed with three different categorized: natural treatment, artificial treatment, and chemical treatment. From the results of experiment, it was considered that the most efficient method of reducing pH of recycled aggregate was the chemical treatment using acid such as $CO_2$ acceleration or monoammonium phosphate (MAP), and diammonium phosphate (DAP). Especially, using MAP and DAP, fertilizers, is the most efficient method of reducing pH with its time duration and performance.

Determination of Chloramphenicol by Differential Pulse Polarography (미분 펄스 폴라로그래피에 의한 Chloramphenicol의 정량분석)

  • Younghee Hahn;Jung-Sun Jeon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.4
    • /
    • pp.552-557
    • /
    • 1992
  • Chloramphenicol was studied by differential pulse polarography (DDP). A reduction peak which is dependent on pH of the solution appeared in the voltage range between zero and -1.50 volt vs. Ag/AgCl (sat. KCl) reference electrode. A plot of peak potentials (Ep) measured at room temperature (20$^{\circ}C$) vs. pH of the chloramphenicol solutions showed linear relationship changing slope (Ep/pH) at pH 8.9. The slope was -59.7 mV/pH in pH 2.7∼8.9 and -24.3 mV/pH in pH 8.9∼11.2, respectively. A log plot of peak currents (ip) vs. concentrations showed a linearity at the concentrations between 4.8 ${\times}$ 10$^{-7}$ M and 6.2 ${\times}$ 10$^{-5}$ M (0.16 ppm∼20 ppm) chloramphenicol in pH 8.0 ammonium buffer. Between the DPP method and the reference method measuring absorbance at 278 nm, the correlation coefficient was 0.996, which means an excellent linearity. The DPP method was able to detect degradation products of chloramphenicol in mild alkaline solution (pH = 8.0) more distinctly than the spectrophotometric method.

  • PDF

Studies on Chlorinated Tolyl Compounds. (Tolyl계 Chloro 화합물에 관한 연구)

  • 조윤상
    • YAKHAK HOEJI
    • /
    • v.18 no.2
    • /
    • pp.145-156
    • /
    • 1974
  • P, P'-Hexachiorobitolyl, p, p-hexachlorobitolylketone and p, p' hexachlorobitolylthiourea were synthesized by the radical chlorination method of Hass and McBeer. Among these comppounds, l wormicidal activity of p.p'-hexachlorobitolythiourea was much most potent against Clonorchis sinensis than Hetol in vitro. In the process of the p, p'-biolyl chlorination, ${\alpha, \alpha, \alpha}$-trichlorobitolyl was not detected, but small amount of ${\alpha, \alpha, \alpha}$-dichlorobitolyl was detected. This compound was immediately converted bitolyl compounds were analyzed, linear relationship was observed between retention indices and number of chlorine in two series of odd and even numbered chlorine compounds.

  • PDF

Fabrication and Calibration of pH Sensor Using Suspended CNT Nanosheet (부양형 탄소나노튜브 나노시트를 이용한 pH센서의 제작과 보정)

  • Ryu, Hyobong;Choi, WooSeok;An, Taechang;Heo, Joonseong;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.207-211
    • /
    • 2013
  • In this research, the pH sensor was developed using CNT nanosheet with Nafion coating for the advanced medical sensor such as a blood gas analyzer. The CNT nanosheet was formed by dielectrophoresis and water-meniscus between cantilever-type electrodes. Then, the process of the heat annealing and the Nafion coating was conducted for reducing contact resistance and giving proton selectivity respectively. We measured the response of the pH sensor as the electrolyte-gated CNT-nanosheet field effect transistor. The sensor showed a linear current ratio in a similar range of the normal blood pH. A calibration method for decreasing of the response variation among sensors has also been introduced. Coefficient of variance of the pH sensor was decreased by applying the calibration method. A linear relation between the calibrated response of the sensors and pH variance was also obtained. Finally, the pH sensor with a high resolution was fabricated and we verify the feasibility of the sensor by applying the calibration method.

Electric properties Analysis and fabrication of ZnO:As/ZnO:Al homo-junction LED (ZnO:As/ZnO:Al homo-junction LED의 제조와 전기적 특성 분석)

  • Kim, Kyeong-Min;So, Soon-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.55-56
    • /
    • 2007
  • The p-type ZnO thin film, fabricated by means of the ampoule-tube method, was used to make the ZnO p-n junction, and its characteristics was analyzed. The ampoule-tube method was used to make the p-type ZnO based on the As diffusion, and the hall measurement was used to confirm that the p-type is formed. the current-voltage characteristics of the ZnO p-n junction were measured to confirm the rectification characteristics of a typical p-n junction and the low leakage voltage characteristics. Using the ampoule-tube to fabricate the p-type ZnO will provide a very useful technology for producing the UV ZnO LED and ZnO-based devices.

  • PDF

Brain-Machine Interface Using P300 Brain Wave (P300 뇌파를 이용한 뇌-기계 인터페이스 기술에 대한 연구)

  • Cha, Kab-Mun;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.18-23
    • /
    • 2010
  • In this paper, we propose a computationally efficient method detecting the P300 wave for brain-machine interface. Electrophysiological researches have shown that the P300 wave's potential is decreased when human intention matches visual stimulation. Motivated by this fact, we can infer human intention for brain-machine interface by detecting the P300 wave's potential decrease. The P300 wave is recorded from EEG(electroencephalogram) electrodes attached on human brain skull after giving alphabetical stimulation. To detect the potential decrease in P300, firstly we statistically model the P300 wave's negative potential. Then we infer human intention based on maximum likelihood estimation. The proposed method was evaluated on the data recorded from three healthy human subjects. The method achieved an averaging accuracy of 98% from subject k, 90% from subject j and 79.8% from subject h.

PH Characteristics of Precipitation in Seoul Area (서울 지역에 내린 우수 pH 특성)

  • Lee, Min-Hee;Eiji, Hirai;Motoichi, Miyazaki;Tetsuri, Chahji;Hao, Quan
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.1-7
    • /
    • 1994
  • Rainwater was collected in Seoul area from January 1991 to December 1993 (over 3years) and by the analysis of the chemical components contained in rainwater, investigated the components that effect on rainwater pH Through the above studies the following conclusions were obtained. 1) Method for Averaging pH Volume weighted method is considered to be acceptable providing that precipitation is measured at the same time when the samples are taken, without precipitation data a simple averaging method should be the next choice. 2) Annual average rainwater pH was 4.98 in 1991, 4.80 in 1992, 4.67 in 1993, measurement range was 3.6-8.1. 3) In the relationship between rainwater pH and rainfall amounts rainwater pH for light rain(<15mm rainfall) was existent in the wide range(pH 4-7), but for heavy rain was corresponded to the annual average values. 4) Annual frequency of pH was Birrndat the frequency($\gamma $) between the density of the [$H^{+}$] and pH in the rainwater(over 3years ), $NO_{3}^{-}$ was excellent and the obtained results was 0.62 in 1992. Also In the correlation coefficient($\gamma $) according to the pH range $SO_{4}^{2-}, NO_{3}^{-}$, were 0.85 ,0.68 at 3.6 $Cl^-$ was 0.99(1993). At 4.1$NO_{3}^{-}(\gamma=0.48)$ in 1992, SO_4^{2-}($\gamma$=0.54), $NO_{3}^{-}(\gamma$=0.72), $Cl^- (\gamma$=0.49) in 1993. 6) pH values gradually increased with increase in $Ca^{2+}/SO_{4}^{2-}$.

  • PDF

An Access Control using Reputation Information in P2P File Sharing System (P2P 파일 공유 시스템에서 평판 정보를 이용한 접근 제어)

  • Shin Jung-Hwa;Shin Weon;Rhee Kyung-Hyune
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.493-498
    • /
    • 2005
  • P2P service is a method that can share various information through direct connection between computer of a person who have information and a Person who have information without server in the Internet and it is getting a lot of popularity by method for free ex change of file. P2P file sharing systems have become popular as a new paradigm for information exchange. Because all users who use service in P2P file sharing system can use shared files of several users freely by equal access privilege, it is happening the 'free rider' that only download shared file of other users without share own files. Although a user share a malicious file including virus, worm or file that have title differing with actuality contents, can use file sharing service without limitation. In this paper, we propose a method that restrict access of 'free rider' that only download using reputation information that indicate reliability of user. Also, we restrict usage ons hared file of other users about users who share harmful file.

ForwardCast : A New VOD Streaming Method in P2P (포워드캐스트(ForwardCast) : P2P에서의 새로운 VoD 스트리밍 방법)

  • Yoon Soo-Mi;Kim Sang-Chul;Kim Joong-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.12B no.7 s.103
    • /
    • pp.783-788
    • /
    • 2005
  • Recently researches that apply P2P networks to VOD streaming have been actively published In the previous works on VOD streaming, they aimed at achieving two major goals, which are zero-delay transmission and minimization of service rejection ratio. This paper proposes a new method, called ForwardCast, for VOD streaming based on a P2P-based multicasting tree in order to achieve theses two goals. In this method,- basically a new client selects one of the preceding clients and starts receiving a whole video from the selected one without any delay. In some situation, two preceding clients are selected to transfer the ending part of the video and its the remaining part simultaneously. In our experiment, ForwardCast can reduce the rejection ratio compared to previous works without increasing server stress.