Abstract

In this research, the pH sensor was developed using CNT nanosheet with Nafion coating for the advanced medical sensor such as a blood gas analyzer. The CNT nanosheet was formed by dielectrophoresis and water-meniscus between cantilever-type electrodes. Then, the process of the heat annealing and the Nafion coating was conducted for reducing contact resistance and giving proton selectivity respectively. We measured the response of the pH sensor as the electrolyte-gated CNT-nanosheet field effect transistor. The sensor showed a linear current ratio in a similar range of the normal blood pH. A calibration method for decreasing of the response variation among sensors has also been introduced. Coefficient of variance of the pH sensor was decreased by applying the calibration method. A linear relation between the calibrated response of the sensors and pH variance was also obtained. Finally, the pH sensor with a high resolution was fabricated and we verify the feasibility of the sensor by applying the calibration method.

Keywords

References

  1. W. Shi, S. He, M. Wei, D. G. Evans, and X. Duan, "Optical pH sensor with rapid response based on a fluorescein-intercalated layered double hydroxide", Advanced Functional Materials, Vol. 20, No. 22, pp. 3856-3863, 2010. https://doi.org/10.1002/adfm.201001081
  2. Y.-H. Chang, Y.-S. Lu, Y.-L. Hong, S. Gwo, and J. A. Yeh, "Highly sensitive pH sensing using an indium nitride ion-sensitive field-effect transistor", IEEE Sensors Journal, Vol. 11, No. 5, pp. 1157-1161, 2011. https://doi.org/10.1109/JSEN.2010.2080317
  3. W. Gao and J. Song, "Polyaniline film based amperometric pH sensor using a novel electrochemical measurement system", Electroanalysis, Vol. 21, No. 8, pp. 973-978, 2009. https://doi.org/10.1002/elan.200804500
  4. T. An, W. Choi, E. Lee, I. Kim, W. Moon, and G. Lim, "Fabrication of functional micro- and nanoneedle electrodes using a carbon nanotube template and electrodeposition", Nanoscale Research Letters, Vol. 6, No. 1, p. 306, 2011. https://doi.org/10.1186/1556-276X-6-306
  5. R. Zhao, M. Xu, J. Wang, and G. Chen, "A pH sensor based on the $TiO_2$ nanotube array modified Ti electrode", Electrochimica Acta, Vol. 55, No. 20, pp. 5647-5651, 2010. https://doi.org/10.1016/j.electacta.2010.04.102
  6. R. C. Somers, R. M. Lanning, P. T. Snee, A. B. Greytak, R. K. Jain, M. G. Bawendi, and D. G. Nocera, "A nanocrystal-based ratiometric pH sensor for natural pH ranges", Chem. Sci., Vol. 3, No. 10, pp. 2980-2985, 2012. https://doi.org/10.1039/c2sc20212c
  7. N. Lei, P. Li, W. Xue, and J. Xu, "Simple graphene chemiresistors as pH sensors: Fabrication and characterization", Meas. Sci. Technol., Vol. 22, No. 10, p. 107002, 2011. https://doi.org/10.1088/0957-0233/22/10/107002
  8. T. An, K. S. Kim, S. K. Hahn, and G. Lim, "Realtime, step-wise, electrical detection of protein molecules using dielectrophoretically aligned SWNT-film FET aptasensors", Lab Chip, Vol. 10, No. 16, pp. 2052-2056, 2010. https://doi.org/10.1039/c005276k
  9. T. An, W. Choi, S. W. Joo, and G. Lim, "A novel fabrication method of CNT-CP composite single nanowires self-templated by dielectrophoresis and electropolymerization", Physica Status Solidi (RRL) - Rapid Research Letters, Vol. 5, No. 7, pp. 235-237, 2011. https://doi.org/10.1002/pssr.201105223
  10. W. Choi, T. An, and G. Lim, "Organic electrochemical transistors based on a dielectrophoretically aligned nanowire array", Nanoscale Research Letters, Vol. 6, No. 1, p. 339, 2011. https://doi.org/10.1186/1556-276X-6-339
  11. F. N. Ishikawa, M. Curreli, H.-K. Chang, P.-C. Chen, R. Zhang, R. J. Cote, M. E. Thompson, and C. Zhou, "A calibration method for nanowire biosensors to suppress device-to-device variation", ACS Nano, Vol. 3, No. 12, pp. 3969-3976, 2009. https://doi.org/10.1021/nn9011384

Cited by

  1. Evaluation of Electrospun TiO2/PVP/LiCl Nanofiber Array for Humidity Sensing vol.23, pp.1, 2014, https://doi.org/10.5369/JSST.2014.23.1.42
  2. Fabrication of Biofuel Cell Roll Using Flexible CNT Nanosheet Substrate vol.23, pp.6, 2014, https://doi.org/10.5369/JSST.2014.23.6.388
  3. Organophosphorus Compounds Detection Using Suspended SWNT Films vol.22, pp.5, 2013, https://doi.org/10.5369/JSST.2013.22.5.346