An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

Particle Size Distribution of Heavy Metals in the Urban Air of Seoul, Korea

  • Sohn, Dong-Hun;Heo, Moon-Young;Kang, Choon-Won
    • Archives of Pharmacal Research
    • /
    • v.12 no.3
    • /
    • pp.214-218
    • /
    • 1989
  • Atmospheric particulate matters (A. P. M. ) were collected on quartz-fiber filters from March 1985 to May 1986, using the Andersen high-volume air sampler and contents of six heavy metals (Fe, Mn, Cu, Zn, Pb Ni) in the A. P. M. were determined by atomic absorption spectrophotometry. These heavy metals were divided into the three groups with respect to their particle size distribution. Fe and Mn were mainly associated with coarse particles (diameter > 2.0 $\mu$m), but Pb and Ni were related fine particles (diameter < 2.0 $\mu$m). Cu and Zn had mized size distributions in both of them. In the seasonal variation of heavy metals, the contents of Fe and Mn in spring and Ni and Pb in winter were higher than any other season. There were high mutual correlation between Fe and Mn coarse particles, and between Pb and Ni in fine particles.

  • PDF

Multiplex Digital SSB Modulators and TDM/FDM Translator (다중 디지털 단측파대 변조기와 TDM/FDM 변환 장치에 관한 연구)

  • 박종연;박의열
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 1983
  • The 12-Channe1 TDM/FDM translator is proposed which uses a periodically varying digital filter and the multiplexing weaver modulators. The general 12-Channel TDM/FDM translator using the Weaver modulators requires 24 interpolating FIR(finite impulse response) filters and 24 sinusoidal modulators, however the TDM/FDM translator proposed in this paper consists of one interpolating periodically varying digital filter and 12 sinusoidal modulators. The results obtained in this paper show that the system is simplified and the computation time is reduced. These facts are verified by the computer simulation.

  • PDF

The Method of Simplifying TDM/FDM Translation System and the Reduction of the Translation Time (TDM/FDM 변환 장치의 단순화 방법의 변환 시간의 단축)

  • 박종연;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.3
    • /
    • pp.21-28
    • /
    • 1983
  • Four new types of TDM/FDM translation system are proposed in this paper. In the proposed system, the periodically time varying filters (P.V.F) are used in order to modify the general TDM/FDM conversion systems. The new systems have the simple structure as compared with the existing systems and the multiplication rate is reduced to about 2.0${\times}$10 multiplications/s$.$channel. It is verified by the computer simulation that the proposed systems can be used as 12-channel TDM/FDM translation systems.

  • PDF

A New Adaptive, Semantically Clustered Peer-to-Peer Network Architecture

  • Das S;Thakur A;Bose T;Chaki N
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.159-164
    • /
    • 2004
  • This paper aims towards designing and implementation of a new adaptive Peer to Peer (P2P) network that cluster itself on the basis of semantic proximity. We also developed an algorithm to classify the nodes to form the semantic groups and to direct the queries to appropriate groups without any human intervention. This is done using Bloom filters to summarise keywords of the documents shared by a peer. The queries are directed towards the appropriate clusters instead of flooding them. The proposed topology supports a system for maintaining a global, omnipresent trust value for each peer in an efficient manner both in terms of decision time and network load.

  • PDF

A Study on the Contamination of Saline Used in the Operation (수술에 사용하는 생리식염수의 오염수준 변화)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.99-109
    • /
    • 1995
  • Post-operative wound infections have been the serious problems in nursing care in the operating room and appear to be strongly related to the infection occurring during the operation. The purpose of this study is to identify the level of contamination in saline used in the operation and also examine the correlation between the contaminated saline and the length of the operation, and unclean atmospheric factor. Subjects for this study include 13 cases of operation performed at the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between Oct. 6 through Dec. 10, 1994 by the author and anurse who worked in the operating room. For the study, multiple batches of saline sample were collected at the various time intervals duringthe operation and filtered through the membrane filters. Viable microorganisms retained on the filters were cultured on the appropriate culture media and the levels of existing cells in saline were enumerated according to Koch's method. In the analyses of the data, Pearson's correlation coefficient was obtained for the examination of relationship between the length of operation and numbers of microorganisms existing in saline and for the comparison of the differences in numbers if microrganisms in saline sample collected at the various operative stages, e. g. pre-incision, excision and skin suturing stages, ANOVA and Scheff Tests were performed. The results of this study are summarized as follows. 1) The lenth of the operation and numbers of microorganisms in the saline used in the operation appeared to be significantly correlated (r=0.5467, P<0,001). 2) In case of saline exposed to air, but not used in the operation, the length of exposure to the air and the numbers of microorganisms present in saline also showed an apparent correlation(r=0.5087, P<0. 001). 3) The frequencies of occurrence of microorganisms in saline used in the operation and in saline exposed only to the air in the given time showed significant differences(t=3.73, p=.0000). 4) In case of saline used in the operation, there is significant differences in its numbers of contained microorganisms between the operative stages ; pre-incision, excision, and skin suture (F=17.7500, p=.0000). 5) In case of saline exposed only to the air in the given time, there is significant differences in its numbers of contained microorganisms between the operative stages . pre-incision, excision, and skin suture(F=6.3807, p=.00031).

  • PDF

An Experimental Study on Filtration Efficiency and BPT Characteristics by PM Loading in Partial-diesel Particulate Filter (포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구)

  • Oh, Kwang-Chul;Lee, Kyung-Bok;Lee, Chun-Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.147-154
    • /
    • 2012
  • The number of vehicles applied diesel engine are rapidly rising for fuel economy. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced emission regulation. The Diesel Particulate Filter (DPF) system is considered as the most efficiency method to reduce particulate matter (PM) by car makers but also in retrofit market. In recently, various kinds of partial flow DPF are widely used for proper filtration performance and reducing of pressure drop but it is difficult to define the characteristics of these filters because the filtration mechanism is obscure according to the status of these systems. In this paper we investigated the characteristics of cell open type DPF according to the status of filter especially, PM loading. The PM loading mass in the p-DPF are predicted from increase of differential pressure of DPF and the trend of filtration efficiency so that we can measure filtration efficiency and Balance Point Temperature (BPT) of this p-DPF according to PM loading.

Statistical Analysis of the MSE for the MDPSAP Adaptive Filter (MPDSAP 적응필터를 위한 MSE의 통계적 해석)

  • Kim, Young-min;Choi, Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.883-887
    • /
    • 2009
  • This paper presents a statistical analysis of the MSE of adaptation for the MPDSAP (Maximally polyphase decomposed Subband Affine Projection) algorithm for the an autoregressive (AR) inputs with P order. In subband structure, the Affine Projection (AP) algorithm is transformed to the Normalized Least Mean Square (NLMS) algorithm by applying the polyphase decomposition and the noble identity to the adaptive filter. And also, AR input can be pre-whitened by subband filtering with the Orthonormal Analysis Filters(OAF). In the subband structure, the pre-whitening of the AR(P) inputs provides simple and valid approximations for a statistical analysis of the MSE behaviors for the SAP adaptive filter.

  • PDF

Studies on sterile filters in the preparation of N-13 ammonia injection (N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가)

  • Oh, Chang Bum;Kim, Si Hwal;Cha, Min Jung;Shin, Jin;Ji, Yong Gi;Choi, Sung Ook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2019
  • Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.