• Title/Summary/Keyword: p-filters

Search Result 219, Processing Time 0.029 seconds

Polarization Filters Using the Multicomponent Complex Trace Analysis (다성분 복소트레이스를 이용한 분극필터)

  • Kim, Ki-Young;Lee, So-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.89-94
    • /
    • 2006
  • In order to increase the signal-to-noise ratio in multi-component seismic data, we developed new polarization filters based on the method of multicomponent complex trace analysis. Unlike the previous polarization filters, the present filters separately compute linear and elliptic components at each time sample using amplitude ratio of horizontal and vertical components of body waves and ellipticity of Rayleigh waves. The polarization filters work ideally even with low S/N data. Application of the filters to both synthetic and real seismic data shows that Rayleigh waves of elliptic motions are effectively eliminated and both P and S waves of linear motions are well separated each other.

  • PDF

Graphical Representation of the Instantaneous Compensation Power Flow for Single-Phase Active Power Filters

  • Jung, Young-Gook
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1380-1388
    • /
    • 2013
  • The conventional graphical representation of the instantaneous compensation power flow for single-phase active power filters(APFs) simply represents the active power flow and the reactive power flow which flowing between the power source and the active filter / the load. But, this method does not provide the information about the rectification mode and the compensation mode of APFs, especially, the loss for each mode was not considered at all. This is very important to understand the compensation operation characteristics of APFs. Therefore, this paper proposes the graphical representation of the instantaneous compensation power flow for single-phase APFs considering the instantaneous rectification mode and the instantaneous inversion mode. Three cases are verified in this paper - without compensation, with compensation of the active power 'p' and the fundamental reactive power 'q', and with compensation of only the distorted power 'h'. To ensure the validity of the proposed approach, PSIM simulation is achieved. As a result, we could confirm that the proposed approach was easy to explain the instantaneous compensation power flow considering the instantaneous rectification mode and the instantaneous inversion mode of APFs, also, Total Harmonic Distortion(THD)/Power Factor (P.F) and Fast Fourier Transform(FFT) analysis were compared for each case.

Reflectance Spectrum of Main Belt Asteroid P/2010 A2

  • Kim, Jun-Han;Ishiguro, Masateru;Hanayama, Hidekazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.41.2-41.2
    • /
    • 2011
  • P/2010 A2, a main-belt asteroid having comet-like dust trail was discovered in January 2010, but the origin of the trail is controversial. Moreno et al. (2010) reported water-ice sublimation as a mechanism for the comet-like activity, whereas other researches (Jewitt et al. 2010; Snodgrass et al. 2010) stated that impact collision contributed to the dust trail. For asteroids are categorized based on spectral shape, optical observation using different color filters makes it possible to determine the taxonomic type of P/2010 A2 nucleus, thus gives an answer to the question of activation mechanism of the object. In this presentation, we report multiband observation of P/2010 A2 in January and March 2010 with 1-meter telescope of Ishigaki-Jima Astronomical Observatory. We employed three broadband filters of g', Rc, and Ic. In this presentation, we focus on the data acquisition, the reduction and the derivation of the reflectance spectrum of debris in the trail. Finally we discuss the potential cause of dust ejection from this asteroid.

  • PDF

A Proposal of New Hybrid Passive Harmonic Filter for AC Motor Drive Line Filter Size Reduction (AC모터드라이브 라인필터의 축소화를 위한 신형 하이브리드고조파필터 제안)

  • Park, Byung-Ju;Yoon, Dong-Chul;Oh, Jeong-Cheol;Bae, Byung-Yeol;Hwang, An-il;Yoo, Hang-Kyu;Choi, Seok-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • ACL and DCL are have been conventionally used for reducing harmonic current on the input side of an ACMD. The current distortion ratio ITHD using ACL and DCL is only 35% to 85%, therefore to satisfy the IEEE Std. 519 requirements, the line filters has been focused as an alternative means. Those are installed between the AC power supply and the input of the ACMD, and must meet the IEEE Std. 519, be economical and be compact. To contribute to the widespread of using these line filters, we discussed concerning its topologies, simulation results, prototype test results as well as the cost evaluations. It included not only the proposed (NHHF) new hybrid harmonic filters which have both merits of simplicity and economic but also the past (BBHF) broadband harmonic filters and (HHF) hybrid harmonic filters.

Effect of Mask Filter on Respiratory Function in Chronic Stroke Patients (마스크 필터가 만성 뇌졸중 환자의 호흡기능에 미치는 영향)

  • Lee, Yun-Hee;Kum, Dong-Min;Shin, Won-Seob
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.149-155
    • /
    • 2022
  • Purpose : This study investigated the effects of wearing a mask and different mask filters on the respiratory function of stroke patients. Methods : A total of 15 stroke patients were selected according to the inclusion and exclusion criteria. The respiratory functions were compared between participants with and without masks and among respiratory functions with three different mask filters. The order of using masks was non-wearing masks, Dental masks, KF80 masks, and KF94 masks; the difference in respiratory volumes among these conditions were measured. For accuracy of the measurement, sufficient education on the respiratory measurement method was provided to the researcher, and the heart rate of the participants was estimated to confirm their stability before the measurements. To ensure accuracy, the subjects were educated on the researchers' respiratory measurement methods. Each measurement was followed by 10 min breathing stability before replacing the next mask. Results : The results of this study showed that the difference in respiratory functions, including forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and maximal voluntary ventilation (MVV), in stroke patients was statistically significant among different masks (p<.05). Afterwards, the values of FVC, FEV1, and MVV in stroke patients wearing masks were significantly lower than those of the non-masked control group (p<.05). The difference in respiratory functions with different mask filters showed no statistical significance (p<.05). Conclusion : This study showed that participants wearing any of the masks presented a lower respiratory function than that of those without using masks; additionally, no difference in respiratory functions was observed with differences in mask filters. Therefore, wearing a mask for a prolonged period is confirmed to affect breathing in stroke patients with weak respiratory function.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

STABILIZERS ON SHEFFER STROKE BL-ALGEBRAS

  • Katican, Tugce;Oner, Tahsin;Saeid, Arsham Borumand
    • Honam Mathematical Journal
    • /
    • v.44 no.1
    • /
    • pp.78-97
    • /
    • 2022
  • In this study, new properties of various filters on a Sheffer stroke BL-algebra are studied. Then some new results in filters of Sheffer stroke BL-algebras are given. Also, stabilizers of nonempty subsets of Sheffer stroke BL-algebras are defined and some properties are examined. Moreover, it is shown that the stabilizer of a filter with respect to a/n (ultra) filter of a Sheffer stroke BL-algebra is its (ultra) filter. It is proved that the stabilizer of the subset {0} of a Sheffer stroke BL-algebra is {1}. Finally, it is stated that the stabilizer St(P, Q) of P with respect to Q is an ultra filter of a Sheffer stroke BL-algebra when P is any filter and Q is an ultra filter of this algebra.

Direct Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Objective : Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filters during CAS. Methods : A total of 107 patients underwent CAS with use of a distal protection filter. Angiographic carotid plaque surface morphology was classified as smooth, irregular, and ulcerated. To determine predictable factors of filling defect in the protection filters, 11 variables were retrospectively analyzed which might influence filling defect in the protection filters during CAS. Results : Filling defects during CAS were presented in the 33 cerebral protection filters. In multivariate analysis, angiographic ulceration [odds ratio (OR), 6.60; 95% confidence interval (CI) : 2.24, 19.4; p=0.001], higher stenosis degree (OR, 1.06; 95% CI : 1.00, 1.12; p=0.039), and coexistent thrombus (OR, 7.58; 95% CI : 1.69, 34.05; p=0.08) were highly associated with filling defect in the cerebral protection devices during CAS. Among several variables, angiographic surface ulceration was the only significant factor associated with flow stagnation during CAS (OR, 4.11; 95% CI : 1.33, 12.72; p=0.014). Conclusion : Plaque surface morphology on carotid angiography can be a highly sensitive marker of plaque instability during CAS. The independent risk factors for filling defect in the filter devices during CAS were plaque ulceration, stenosis degree, and coexistent thrombus.

Residual P-Finiteness of Certain Generalized Free Products of Nilpotent Groups

  • Kim, Goan-Su;Lee, Young-Mi;McCarron, James
    • Kyungpook Mathematical Journal
    • /
    • v.48 no.3
    • /
    • pp.495-502
    • /
    • 2008
  • We show that free products of finitely generated and residually p-finite nilpotent groups, amalgamating p-closed central subgroups are residually p-finite. As a consequence, we are able to show that generalized free products of residually p-finite abelian groups are residually p-finite if the amalgamated subgroup is closed in the pro-p topology on each of the factors.

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.