• Title/Summary/Keyword: p chart

Search Result 385, Processing Time 0.025 seconds

A Design of Control Chart for Fraction Nonconforming Using Fuzzy Data (퍼지 데이터를 이용한 불량률(p) 관리도의 설계)

  • 김계완;서현수;윤덕균
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.2
    • /
    • pp.191-200
    • /
    • 2004
  • Using the p chart is not adequate in case that there are lots of data and it is difficult to divide into products conforming or nonconforming because of obscurity of binary classification. So we need to design a new control chart which represents obscure situation efficiently. This study deals with the method to performing arithmetic operation representing fuzzy data into fuzzy set by applying fuzzy set theory and designs a new control chart taking account of a concept of classification on the term set and membership function associated with term set.

Solubility, vapor pressure, duhring and enthalpy-concentration charts of$H_2$O/(LiBr+$CaC1_2$) solution as a new working fluid ($H_2$O/(LiBr+$CaC1_2$) 3성분계 작동매체의 용해도, 증기압측정 및 듀링 선도, 엔탈피-농도 선도 작성)

  • 이형래;구기갑;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.666-673
    • /
    • 1998
  • Solubilities (LiBr+$CaC1_2$) in water were measured at temperatures form 267.51 to 306.17K for $CaC1_2$ (LiBr+$CaC1_2$)=0.24 by mole. Experimental data were correlated with polynomial equations. Average absolute deviations between the measured and calculated values were 0.31% at concentration smaller than 60wt% and 0.41% at concentration larger than 60wt%, respectively. Vapor pressures were measured at temperatures from 296.75 to 436.75K and concentrations from 40 to 70wt%. Vapor pressure data were fitted to a Antoine-type equation and average absolute deviation was 2.98%. The P-T-X chart and H-T-X chart of $H_2O$/(LiBr+$CaC1_2$) system were constructed by using the correlation equations of solubility, vaper pressure, and heat capacity. The P-T-X chart indicates that $H_2O$/(LiBr+$CaC1_2$) system has potential as a possible working fluid for air-cooled absorption chillers.

  • PDF

An Analysis of the Control Limit in p-chart Applying Binomial Distribution Using Commercial Software

  • Yoo Wang-Jin;Park Won-Joo
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.198-207
    • /
    • 1998
  • The p chart approximate to the normal distribution has a difficulty to analyze the process condition precisely when the negative LCL is occurred. Furthermore, the probability of Type I error increases compared with using its original binomial distribution. For a long time the p chart has been used as approximated to the normal distribution because of its easy use. However, it becomes rapid and convenient to calculate the binomial distribution through the development of computer and software, so it is strongly suggested to use the binomial distribution determining control limits to reduce the probability of Type I error. In this study, I suggest that the control limits can be designed in use of binomial distribution and they can be utilized without special software by illustrating the certain work for establishing p-chart with the commercial one(EXCEL).

  • PDF

Application of Dynamic $\bar{x}$-R Control Chart for Advanced Phase Isolation Ditch (APID) Process (APID공정 내 공정진단을 위한 dynamic $\bar{x}$-R 관리도의 적용)

  • An, Sang-Woo;Kwak, Sung-Keun;Jung, Young-Wook;Chung, Mu-Keun;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.704-712
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate and monitor the effluent water quality ($BOD_5$, SS, T-N, and T-P) and operating conditions (Influent, SVI, SRT, and HRT) as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 7.7, 5.6, 10.8, and 1.6 mg/L. Trend analysis of influent $BOD_5$, SS, T-N, and T-P in APID process were illustrated that APID process need for more strong APID process management on the winter session, such as developing new intermediated aeration mode, operating methods, and managements strategy. At the application of control chart, the signal of uncommon effects at APID process was determined much higher existing control chart tntr conventional control chart in this study. These results indicate that conventional control chart has been collected and determined cleary signal at only stable situation. Therefore, newly developed APID process of dynamic control chart can be one of the useful tool for monitoring and management process.

Effect of Under and Over Refractive Correction on Visual Acuity Performance using Two Different Charts

  • Chen, Ai-Hong;Shah, Siti Salwa Mohamad;Rosli, Saiful Azlan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.291-295
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of under and over refractive correction on visual acuity performance and the variation of the visual performance measurement using two different visual acuity charts. Methods: Ten young adults, aged between 19 and 25 years old, were recruited. Inclusion criteria: no history of ocular injury or pathology with a best-corrected visual acuity of 6/6 on dominant eye. The over and under refractive corrections were induced using minus and plus spherical ophthalmic lenses in 0.50 D steps up to 3.00 D; as well as using three axis orientations of cylindrical ophthalmic lenses ($45^{\circ}$, $90^{\circ}$ and $180^{\circ}$) in 0.50 D steps. The variation of visual acuity performance measurements was investigated using Bailey-Lovie LogMAR chart and Landolt C chart. Results: The visual acuity changes with lenses were significantly different between two charts [F = 49.15, p < 0.05 with plus spherical ophthalmic lenses and F = 174.38, p < 0.05 with minus spherical ophthalmic lenses]. The visual acuity changes with three different cylindrical axis showed no significant difference between Bailey-Lovie LogMAR chart [F = 2.35, p > 0.05] and Landolt C chart [F = 3.12, p = 0.05]. Conclusions: The over and under refractive correction affected the visual acuity performance differently. The Landolt C chart and Bailey-Lovie LogMAR chart demonstrated variation in measurements.

The Design of Robust Control Chart for A Contaminated Process (오염된 공정을 위한 로버스트 관리도의 설계)

  • Kim, Yong-Jun;Kim, Dong-Hyuk;Chung, Young-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.3
    • /
    • pp.327-336
    • /
    • 2012
  • Purpose: In this study, we research the hurdle rate method to suggest the robust control chart for a contaminated process less vulnerable to fault values than existing control charts. Methods: We produce the results of p, ARL values to compare the performance of two control charts, $\bar{x}-s$ that has been used typically and TM-TS that is suggested by this paper. We implement the simulation focusing on three cases, change of deviation, mean and both of them. Results: We draw a conclusion that the TM-TS control chart has better efficiency than $\bar{x}-s$ control chart over the three cases. Conclusion: We insist that applying TM-TS control chart for a polluted process is more effective than $\bar{x}-s$ control chart.

Combined VSI EWMA Chart with Accumulate-Combine Method for Moderate or Small Shifts

  • Chang, Duk-Joon
    • Journal of Integrative Natural Science
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In a multivariate normal production process Np(µ,Σ), a chart combining three EWMA charts with accumulate-combine method for µ, variance components of Σ, and off-diagonal elements of Σ, into a EWMA (exponentially weighted moving average) chart is considered, which is called a combined EWMA chart. Through simulation work, the proposed combined EWMA chart's numerical performance and properties are examined. The simulation results show that the proposed combined EWMA chart, which is simultaneously monitoring all the process parameters of multivariate normal production process, works effectively in the perspective of means, variances and correlation coefficients. In addition, the combined EWMA chart is extended to VSI chart.

Overview of Operations Strategy for Service Layout and Statistical Process Control (서비스 배치 및 SPC 운영 전략)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.6
    • /
    • pp.109-118
    • /
    • 2006
  • This paper proposes service layout strategy considering service characteristics by the use of benchmarking production system such as layout by P-Q chart, improvement tool, automated system, Toyota production system and lean production system. This paper represents operation methodology of statistical process control using control chart for service performance outcomes.

Development of Preservation Prediction Chart for Long Term Storage of Fermented Cucumber (발효오이의 산패예견표의 개발)

  • Kim, Jae-Ho;Breidt, Fred
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1616-1621
    • /
    • 2007
  • Off-flavors and odors in fermented cucumbers result from the growth of undesirable microorganisms during the secondary fermentation. Under laboratory conditions using a sterile fermented cucumber slurry medium, the spoilage fermentations were reproduced. Using this system the salt and pH conditions that allow the spoilage to occur were determined by varying the NaCl concentration and pH of the slurry medium. At pH 3, no spoilage was observed, regardless of the salt concentration, while at pH 3.5, pH 4, and pH 4.5, spoilage occurred in the 0 and 2% NaCl samples. For pH 5.0 samples, spoilage products were seen for all NaCl treatments. Based on these results the Preservation Prediction Chart was developed. The Chart may be used for selection of proper pH value and salt concentration for long term storage of fermented cucumber.

A Study on the P~q~t Charts Applicability for Quality Improvement of Water-Sealing&Reinforcement Grouting in Tunneling Work Underneath the City (도심지 지하 터널시공 중 차수·보강 그라우팅 공사의 품질향상을 위한 P~q~t charts 적용성 연구)

  • Kim, Jin-Chun;Kim, Seok-Hyun;Yoo, Byung-Sun;Kang, Hee-Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.3
    • /
    • pp.51-63
    • /
    • 2021
  • This study is for the quality improvement of water-sealing & reinforcement grouting in tunnel of the construction of the underground transportation network underneath the city. Existing tunnel grouting process did not technically utilize P~q~t charts fully. It is due to the absence of technical methods to decide how P~q~t charts change in the presence of trouble and what the change represents in grouting. There were no standards to decide which chart pattern represents which ground characteristics, how to categorize ground types, and how to take measures according to the standards. This paper studies on the grouting type, ground characteristics, ground type categorizing method, and countermeasures for both general and algorithm-processed grouting in soil and rock layer to address the aforementioned problems. Newly improved P~q~t charts from grouting in soil was categorized into six different types. Different characteristics and categorization method was developed for each type. Countermeasures for each type of grouting process were developed so that on-site application can be readily available. Improved P~q~t charts for rock layer also have six different types of grouting. Each type was given the countermeasures for rock layer grouting process for easier applications. Therefore, it is expected to be used through out the entire process of grouting from preparation to the last report of the water-sealing & reinforcement grouting in tunnel of the construction of the underground transportation network underneath the city.