• Title/Summary/Keyword: ozone water

Search Result 583, Processing Time 0.037 seconds

Korean Fifteen-Year-Olds' Alternative Conceptions on the Greenhouse Effect Revealed in PISA Test Results (PISA 검사 결과에서 드러난 만15세 한국 학생들의 온실효과에 대한 대안적 개념)

  • Kwak, Young-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.3
    • /
    • pp.668-674
    • /
    • 2004
  • This study investigated Korean fifteen-year-olds' (mis)conceptions on the greenhouse effect based on the PISA results. Based on previous studies on students' ideas about the greenhouse effect, Korean students'understanding of the natural factors and human-induced factors of the greenhouse effect were analyzed. Students' misconceptions about causes of the greenhouse effect were also examined. In addition to CO2, Students mentioned CFCs, atmospheric pollution, water vapor and methane as greenhouse gases. Many students indicated that the greenhouse effect and ozone depletion have a causal relationship. Teaching implications of the misconceptions were also discussed.

A Study on the Degradation Characteristics of 1,4-dioxane at Different Initial pHs with Advanced Oxidation Process Using $O_3/H_2O_2$ ($O_3/H_2O_2$ 고급산화공정에서 초기 pH 변화에 따른 1,4-dioxane의 제거 특성 연구)

  • Park, Jin-Do;Suh, Jung-Ho;Lee, Hak-Sung
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.404-410
    • /
    • 2005
  • The pH efforts on the removal of 1,4-dioxane and the biodegradobility enhancement of dioxane contaminated water were investigated using $O_3/H_2O_2$ baled advanced oxidation process. Experiments were conducted using a bubble column reactor under different initial pH. The $O_3/H_2O_2$ process effectively converted 1,4-dioxane to more biodegradable intermediates which had a maximum $BOD_5$ enhancement at pH 11 within the experimental range, precisely, when the initial pH increased, $BOD_5$ enhanced. However, in case of removal efficiencies of 1,4-dioxane during $O_3/H_2O_2$ oxidation the optimum condition was shown at pH 9 compared with pH 6 and 11. TOC and COD values were not largely changed for all reaction time. From the results of 1,4-dioxane removal efficiency, TOC, COD, and $BOD_5$ enhancement with reaction time, it was surely observed that 1,4-dioxane was just converted to biodegradable materials, not completely oxidized to carbon dioxide.

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

A Study on the Catalyst for the Synthesis of DME with Hydrogen Energy Density (수소 에너지 밀도가 높은 디메틸에테르(DME) 제조 촉매에 관한 연구)

  • Jang, Eun-Mee;Baek, Young-Soon;Oh, Young-Sam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.445-452
    • /
    • 2008
  • DME(Dimethyl ether) Dimethyl Ether (DME) is a new clean fuel and an environmental-benign energy resource. In comparison with other fuels, DME rapidly decomposes into carbon dioxide ($CO_2$) and water in the atmosphere without forming ozone. It can be manufactured from various energy sources including natural gas, coal, biomass and spent plastics. In addition to its environmentally friendly properties, DME is considered as one of the most promising candidates for the substitute of LPG and diesel fuel. In this work, we will be studied to find optimized condition for the catalyst of DME energy manufacture from hydrogen and carbon oxide and its chemical and physical characteristics.

Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube (수평 평활관내 R245fa의 흐름 응축 열전달 특성)

  • Park, Hyun-Shin;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.

A Study on the Analysis of Solar Radiation Characteristics on a High Elevated Area (고지대 일사량 특성분석에 관한 연구)

  • Jo, Dok-Ki;Kang, Young-Heack;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • The purpose of this study is to procure basic data to be used for solar power plant and concentrating collector designs. Site elevation is one of the major factors which influences the incoming insolation to the earth surface. Because the nonpermanent gases such as ozone, water vapor are unmixed components of the atmosphere and their concentrations are the function of height, the site elevation effects the relative proportion of the atmospheric constituents. We have measured solar radiation on Jiri Mt. (1,400m) and in Gurye area(115m) at the near same latitude. These values were then compared to obtain their characteristics and to investigate the potential for the solar utilization for both high and low elevated areas. From the experimental results, we concluded that 1) Daily mean horizontal global radiation and normal beam radiation on Mt. Jiri are 9.5%, and 35.3% higher than Gurye area respectively for a clear day. 2) A significant difference in atmospheric clearness index is observed between Mt. Jiri and Gurye areas.

Research on the Development of Inline Phosphate Coating Process Technology to Secure the Properties of Parts for Power Transmission Machinery (동력전달용 기계부품의 물성 확보를 위한 인라인 인산염 피막처리 공정기술개발)

  • Kim, Deok-Ho;Ku, Young-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.199-208
    • /
    • 2022
  • The steel wire or steel bar processing process applied to the manufacture of various bolts and power transmission shafts was improved by applying in-line phosphate film treatment technology. By applying a polymer lubricant for a non-reactive metal forming process and a non-reactive non-phosphorus lubricating coating agent, the film formation for each process time was comparatively analyzed and reviewed. Compared to the nine processes applied previously, the in-line phosphate film treatment technology applied with only two processes has been effectively improved in terms of reduction of treatment time, reduction of facility installation area, prevention of water pollution due to wastewater, and non-use of ozone-depleting substances. In addition, it was found that it can have an important effect on productivity improvement and price competitiveness from the simplification of quality control and process control as well as improvement of the working environment.

Impacts of Ultraviolet-B Radiation on Rice-Field Cyanobacteria

  • Sinha, Rajeshwar P.;Hader, Donat-P.
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.439-441
    • /
    • 2002
  • Cyanobacteria are the dominant micro flora in rice-fields, contributing significantly to fertility as a natural biofertilizer. Recent studies show a continuous depletion of the stratospheric ozone layer, and the consequent increase in solar UV-B (280-315 nm) radiation reaching the Earth's surface. UV-B radiation causes reduction in growth, survival, protein content, heterocyst frequency and fixation of carbon and nitrogen in many cyanobacteria. UV -B induced bleaching of pigments, disassembly of phycobilisomal complexes, thymine dimer formation and alterations in membrane permeability have also been encounterd in a number of cyanobacteria. However, certain cyanobacteria produce photoprotective compounds such as water soluble colorless mycosporine-like amino acids (MAAs) and the lipid soluble yellow-brown colored sheath pigment, scytonemin, to counteract the damaging effects of UV-B. Cyanobacteria, such as Anabaena sp., Nostoc commune, Scytonema sp. and Lyngbya sp. were isolated from rice fields and other habitats in India and screened for the presence of photoprotective compounds. A circadian induction of the synthesis of MAAs by UV -B was noted in a number of cyanobacteria. Polychromatic action spectra for the induction of MAAs in Anabaena sp. and Nostoc commune also show the induction to be UV-B dependent peaking at 290 nm. Another photoprotective compound, scytonemin, with an absorption maximum at 386 nm (also absorbs at 300, 278, 252 and 212 nm), was detected in many cyanobacteria. In conclusion, a particular cyanobacterium having photoprotective compounds may be a potent candidate as biofertilizer for crop plants.

  • PDF

Effects of Ozonated Water Treatment on Pesticide Residues and Catechin Content in Green Tea Leaves (녹차의 잔류농약과 카테친 함량에 미치는 오존수 처리 효과)

  • Jung, Kyung-Hee;Seo, Il-Won;Nam, He-Jung;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.265-270
    • /
    • 2008
  • This study examined the effects of treating green tea leaves with ozonated water by evaluating pesticide residue levels and catechin content. The pesticide residue levels of tea leaves treated with carbendazim, captain, diazinon, fenthim, dichlorvos, and chlorpyrifos ranged from 43.2 to 48.2 ppm. For leaves treated by soaking or watering with tap water, or with 0.25 ppm of ozone water for 30 min. Pesticide residue levels were reduced by 24.0-30.2%, 30.3-33.6%, 52.4-70.5%, and 65.5-80.2%, respectively. No major differences in catechin content were observed in the leaves according to the soaking and rinsing treatments using ozonated or tap water.

An Experimental Study on Evaluation of Bond Strength of Arc Thermal Metal Spaying According to Treatment Method of Water Facilities Concrete Surface (수처리 시설물 콘크리트 표면처리 방법에 따른 금속용사 피막의 부착성능 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung;Shin, Jun-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • In this study, the bond strength of metal spraying system by surface treatment of concrete (waterproof/corrosion method) in water treatment facilities was evaluated. The results showed that the system with Sa-P-R-(S) (sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing) led to the desirable performance. The bond strength, the coefficient of water permeability and air permeability were 3.7MPa, $0.68{\ast}10^{-8}cm/sec$, and $0.45{\ast}10^{-16}m^2$, respectively. In scanning electron microscope analysis, the microstructure of specimen coated with perviousness surface hardener was much denser than that without it. Therefore, the specimen coated with sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing had the best bond performance and was the most suitable system to concrete surface in water treatment facilities.