• Title/Summary/Keyword: ozone sensitivity

Search Result 84, Processing Time 0.035 seconds

Ozone Simulations over the Seoul Metropolitan Area for a 2007 June Episode, Part V: Application of CMAQ-HDDM to Predict Ozone Response to Emission Change (2007년 6월 수도권 오존모사 V - 배출량 변화에 따른 오존농도 예측 시 민감도기법 적용)

  • Kim, Soon-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.772-790
    • /
    • 2011
  • In this paper, we use the HDDM (High-order Decoupled Direct Method)-driven ozone sensitivity to predict change in ozone concentrations in response to domain-wide $NO_x$(Oxides of Nitrogen) and VOC (Volatile Organic Compound) emission controls over the Seoul Metropolitan Area during June 11~19, 2007. In order to validate the applicability of HDDM to $NO_x$ and VOC control scenarios, the HDDM results are compared to Brute Force Method (BFM). For VOC controls, NME (Normalized Mean Error) between BFM and HDDM remains less than 2% until the domain-wide VOC emissions are reduced by 80%. The NME for a 40% reduction in the domain-wide $NO_x$ emissions is less than 5% but increases abruptly after further reductions in the $NO_x$ emissions (i.e., 80% reduction). The results indicates that it may be inaccurate to use ozone sensitivity coefficients estimated at a given base emission condition in predicting ozone after $NO_x$ reductions larger than ~50% of the domain total in the SMA. Therefore, HDDM application on piecewise emissions is desirable to predict ozone response to emission controls with accuracy (i.e., truck emissions rather than the domain total). For computational efficiency, HDDM shows approximately 30% faster than the BFM sensitivity approach.

Fabrication of $In_2O_3$-based oxide semiconductor thick film ozene gas sensor ($In_2O_3$ 계 산화물 반도체형 후막 오존 가스센서의 제조)

  • 이규정
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.19-24
    • /
    • 1999
  • $In_2O_3$-based thick films for the ozone detection of ppb range have been investigated. The $In_2O_3$ sensing layer is quite sensitive to ozone, but the saturated stable sensitivity cannot be obtained at the ozone exposure of 100 ppb for 5 min. The addition of $Fe_2O_3$ into $In_2O_3$ indicates some improvement in response time and sensitivity, but it seems the improvement is not good enough for real applications. Firing of $In_2O_3$:$Fe_2O_3$ powder induces remarkable improvement in response and recovery, although the sensitivity decrease. The sensing layer fired at $1300^{\circ}C$ and operated $550^{\circ}C$ shows excellent properties of fast response time, saturated stable sensitivity and rapid recovery characteristics to 100 ppb ozone exposure for 5 min. Especially, it shows the reproducibility of the sensor signal for repeated measurements and the linearity between the ozone concentration and the sensor resistance. The preliminary results clearly demonstrated that the sensor can be successfully applied for the ozone detection of ppb range.

  • PDF

Comparing of Clonal Sensitivity of Populus deltoides to Atmospheric Ozone with Use of Visible Foliar Injury (잎의 가시적(可視的) 피해(被害)에 따른 오존에 대(對)한 미류나무(Populus deltoides) 클론간(間) 감수성(感受性) 비교(比較))

  • Lee, Jae-Cheon;Kim, In-Sik;Yeo, Jin-Kie;Koo, Yeong-Bon
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.1
    • /
    • pp.10-18
    • /
    • 2001
  • Experiments were conducted to compare ozone sensitivity among clones. Ten clones of Papulus deltoides Marsh. were exposured in walk-in type chambers to charcoal-filtered air, 50ppb, 100ppb, and 150ppb ozone for 8h $day^{-1}$ for 21 consecutive days. Occurrence of premature leaf-fall, and visible foliar injury expressed as adaxial stipple were measured after termination of ozone exposure for 3 weeks. Rate of premature leaf-fall increased progressively according to ozone exposure levels. As a result, rate of premature leaf-fall was estimated over 50% at 150ppb ozone. In the charcoal-filtered air and 50ppb ozone treatments, visible foliar injury was not found. But injury was estimated as LA; 17.3%, AA; 6.5%, and LAA; 1.6% to 100ppb ozone treatment and LA; 34.1%, AA; 17.5%, and LAA; 7.4% to 150ppb ozone treatment. Clonal differences of sensitivity within the species were manifested by significant clone differences of adaxial stipple(LAA) in 100ppb and 150ppb ozone treatments.

  • PDF

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

A Study on the Effect of Cumulus Parameterization and Microphysics on Ozone Simulations during Long-range Transport Process over Northeast Asia (동북아 장거리 수송 과정에서 적운 모수화 및 미세물리과정이 오존 모사농도에 미치는 영향 연구)

  • Kang, Jeong-Eon;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.135-151
    • /
    • 2013
  • This study has been carried out to analyze the sensitivity of ozone concentrations by employing different options of cumulus parameterization schemes (CPSs) and microphysics schemes in MM5 models. These sensitivity tests were applied to long-range transport case of higher ozone over Northeast Asia. Employed CPS schemes are Betts-Miller (BM), Grell (GR), Kain-Fritsch2 (KF2), Anthes-Kuo (AK), None scheme (grid scale physics only), and four microphysics used here are Simple ice, Reisner1, Reisner2, Schultz scheme in MM5. We chose two cases of high ozone long range transport case by employing both concentrations ozone level and backward trajectory model. The results showed that modeled ozone concentrations indicated about 10% differences among CPSs. Of the all options, GR and KF2 (for CPS), and Rersiner-1 and Resiner-2 (for microphysics) showed relatively good and stable variations against ensemble mean values. For both CPS and microphysics schemes, the difference of precipitation arising from different parameterization schemes was significant by itself, but the resultant ozone variations showed only marginal. But the cloud fraction differences arising from different parameterization schemes showed better correlation with ozone variations than precipitation differences, indicating that the photochemical ozone generation variations is more dominant by cloud fraction than wet removal process for high and long-ranged transported ozone cases over Northeast Asia.

Numerical Study on the Ozone Formation Sensitivity of Precursors Using Adjoint Model around the South-eastern Area of the Korean Peninsula (수반모형을 이용한 한반도 남동지역의 오존 전구물질의 오존 생성 민감도에 관한 수치연구)

  • Park, Soon-Young;Lee, Soon-Hwan;Lee, Hwa Woon;Kim, Dong-Hyeok
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.669-680
    • /
    • 2013
  • Ozone sensitivity analysis with respect to $NO_x$ is conducted around the south-eastern area of the Korean Peninsula. WRF-CMAQ modeling system is used to simulate a local circulation and high ozone episode day. To analyze the sensitivity, the adjoint model for CMAQ is adopted in this study. The purpose of current study is to investigate the location that affects a day time ozone concentration of these receptors on the high ozone episode day. Adjoint sensitivity analysis for Daegu shows two areas of influence. One is the range from the neighboring location to Pohang and it affects mainly on the same day as receptor time. The other is the remote south-eastern area from Daegu. This remote influence area suggests that $NO_x$ emitted on the previous day can change the ozone concentration at receptor time. The influence area for Busan, on the other hand, is originated only from the emission on the previous day because the sea-breeze occurred on the episode day makes low influence of surrounding emission. The cross sectional analysis reveals that $NO_x$ advection is important not only near the surface of land but also around the height of boundary layer.

Optical Fiber Atmospheric Ozone Monitor (광섬유 대기오존 모니터)

  • 정완영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.201-204
    • /
    • 2002
  • A high accuracy ozone monitor using UV absorption method was developed for ambient ozone monitoring. The system was mainly composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit. The optical signal from the CCD array that provides unusually high response and excellent optical resolution for ozone concentration was converted to digital signal and the digital signal was displayed on screen using PC interface. The optical signal was propagated using optic fiber to reduce optical loss to increase the accuracy of the measuring system. This paper has been studied a interworking signalling protocol between two hybrid networks by analyzing Satellite B-ISDN architecture, DSS2 Layer 3 Signalling protocol, B-ISUP protocol, S-BISUP protocol stack and so on. Also in the paper, messages and primitives have been defined for B-ISDN's Connection Type, Ownership and each protocol in order to connect point-to-multipoint. The ozone sensing properties of the CCD ozone monitor was compared with those of the photo multiplier ozone monitor.

  • PDF

Characteristic Analysis of Tropospheric Ozone Sensitivity from the Satellite-Based HCHO/NO2 Ratio in South Korea (위성 기반 HCHO/NO2 비율을 통한 국내 대류권 오존 민감도 특성 분석)

  • Jinah Jang;Yun Gon Lee ;Jeong-Ah Yu;Kyoung-Hee Sung;Sang-Min Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.563-576
    • /
    • 2023
  • In this study nitrogen dioxide (NO2), formaldehyde (HCHO) from the Ozone Monitoring Instrument (OMI) and TROPOspheric Monitoring Instrument (TROPOMI), OMI/ Microwave Limb Sounder (MLS) tropospheric column ozone (TCO), and Airkorea ground-based O3 data were analyzed to examine the photochemical reaction relationship between tropospheric ozone and its precursors nitrogen oxides (NOx) and volatile organic compounds (VOCs). As a result of analyzing the trend of long-term changes from 2006 to 2020 using OMI satellite data, TCO showed an increasing trend, NO2 steadily decreased, and HCHO continued to increase in Northeast Asia. In addition, formaldehyde nitrogen dioxide ratio (FNR; HCHO/NO2 ratio), an indicator of ozone sensitivity, is gradually increasing, which means that the VOC-limited regime is decreasing. This study conducted a sensitivity analysis of ozone generation using TROPOMI FNR and ground-based ozone (O3) over the recent years (2019~2022) to identify the possible cause for the continuous increase of ozone in Korea. Similar to the previous studies, VOC-limited and transitional regimes appeared in megacities, and VOC-limited regimes also appeared in areas where major power plants were located. In VOC-limited regimes, in other words, areas where NOx is excessively saturated, the reduction in NOx emissions may have weakened the ozone titration and thus led to the increase of ozone. Therefore, VOC emissions should be reduced in the short term rather than NOx emissions to reduce ozone concentrations under the VOC-limited regime.

A Case Study of Risk Assessment of Ozone Impact on Forest Tree Species in Japan

  • Watanabe, Makoto;Yamaguchi, Masahiro;Matsumura, Hideyuki;Kohno, Yoshihisa;Koike, Takayoshi;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.4
    • /
    • pp.205-215
    • /
    • 2011
  • Ozone ($O_3$) is a main component of photochemical oxidants and a phytotoxic air pollutant. Although the current levels of tropospheric $O_3$ in East Asia could adversely affect productivity of forest tree species, risk assessments of $O_3$ impact were limited. In this paper, we summarize the methodology of risk assessment of $O_3$ on forest tree species based on our two previous studies, risk assessments of $O_3$ impact on the growth of Fagus crenata by Watanabe et al. (2012) and on the annual carbon absorption of three representative conifers, Cryptomeria japonica, Pinus densiflora and Larix kaempferi by Watanabe et al. (2010). $O_3$ sensitivity of each tree species obtained from an experimental study, $O_3$ exposure and atmospheric N deposition based on field monitoring and vegetation survey were integrated by geographic information system method. Based on the results, we conclude that the area with high risk of $O_3$ impact does not necessarily correspond to the area with high $O_3$ exposure. The varieties of tree habitat, tree sensitivity to $O_3$ and annual carbon absorption among the tree species, and N deposition-induced change in the $O_3$ sensitivity of F. crenata are raised as the factors of discordance between areas with high risk and those with high $O_3$ exposure. In the last part of this paper, we discuss the present uncertainty and perspectives of risk assessment for the future studies on the impact of $O_3$ on forest tree species in East Asia.

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.