• 제목/요약/키워드: ozone oxidation

검색결과 306건 처리시간 0.028초

Evaluation of Ozone Concentration for the Oxide Thin Film Growth

  • 박노봉;임중관;박용필;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.579-582
    • /
    • 2003
  • Ozone is usually generated from oxygen gas using a silent discharge apparatus and its concentration is less then 10 mol%. Ozone is condensed by the adsorption method, which is widely used for the growth of oxidation thin films such as superconductor. Highly condensed ozone is analyzed by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is most effective in the highly condensed ozone region and its method is superior to Q-mass analyzer for determining ozone concentration because of the simplicity of the method.

  • PDF

오존산화/응집 혼성공정에 의한 UF 분리막의 막오염 저감에 관한 연구 (A study on mitigation of membrane fouling by ozonation/coagulation in ultrafiltration)

  • 김건엽;김민규;이창하;김형수;김지훈;이경일
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.161-168
    • /
    • 2017
  • Microfiltration (MF) and Ultrafiltration (UF) membrane processes capable of producing highly purified water have been extensively applied as a pretreatment process in the wastewater reuse field with the improvement of membrane properties and resistance, development of operating protocols, and improvement of technologies of backwashing and physicochemical cleaning, and improvement of scale and antifoulants. However, despite of the development of membrane production and process technologies, fouling still remains unresolved. This study confirmed that foulants such as polysaccharides, proteins and humic substances existed in final treated effluent (secondary effluent) by fluorescence excitation emission matrix (FEEM) and fourier transform infrared spectroscopy (FTIR) analysis. In addition, when constructing ozone oxidation and coagulation processes as a hybrid process, the removal efficiency was 5.8%, 6.9%, 5.9%, and 28.2% higher than that of the single process using coagulation in turbidity, color, dissolved organic carbon (DOC), and UV254, respectively. The reversible and irreversible resistances in applying the hybrid process consisting of ozone oxidation and coagulation processes were lower than those in applying ozone oxidation and coagulation processes separately in UF membrane process. Therefore, it is considered possible to apply ozonation/coagulation as a pretreatment process for stable wastewater reuse by and then contributing to the reduction of fouling when calculating the optimal conditions for ozone oxidation and coagulation and then to applying them to membrane processes.

4-nonylphenol의 오존산화 처리반응에 관한 연구 (A Study on Ozonation of 4-nonylphenol)

  • 이철규
    • 한국물환경학회지
    • /
    • 제33권6호
    • /
    • pp.736-743
    • /
    • 2017
  • In this study, 4-nonylphenol (4-NP), an endocrine disrupting chemical, was removed by ozone treatment processes under the various experimental conditions including UV irradiation, $TiO_2$ addition. The ozone flow rate and concentration were maintained at $1.0L{\cdot}min^{-1}$ and $70{\pm}5mg{\cdot}L^{-1}$. The pH, COD and TOC of the samples were obtained every 10 minutes for 60 minutes in laboratory scale batch reactor. We found that the combination of UV irradiation and $TiO_2$ addition for ozonation improves the removal efficiency of COD and TOC in 4-NP aqueous solution. In case of the $O_3/UV/TiO_2$ system, COD and TOC were greatly reduced to 85.3 ~ 94.0% and 89.2 ~ 97.2%, respectively. 4-NP degradation rate constants, $k_{COD}$ and $k_{TOC}$, were calculated based on the COD and TOC values. Significantly, $k_{COD}$ and $k_{TOC}$ were improved in the $O_3/UV/TiO_2$ treatment process compared with single $O_3$ process, because the oxidation and the mineralization of 4-NP were increased by generating of the hydroxyl radical. The $k_{COD}$ and $k_{TOC}$ were obtained to be $5.81{\times}10^{-4}{\sim}10.8{\times}10^{-4}sec^{-1}$ and $11.9{\times}10^{-4}{\sim}19.4{\times}10^{-4}sec^{-1}$ in the $O_3/UV/TiO_2$ process. Activation energy ($E_a$) of ozone oxidation reaction based on $k_{COD}$ and $k_{TOC}$ were increased in order of $O_3/UV/TiO_2$ < $O3/UV$ < $O_3/TiO_2$ < $O_3$ process. It was confirmed that the addition of $TiO_2$ and UV irradiation to the ozone oxidation reaction significantly reduced the $E_a$ value and the degradation of 4-NP.

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

생물테러시 실내제독을 위한 효율적인 오존가스의 적용 방법 (Application of Gaseous Ozone for Cleaning Biological Weapon Agent Contaminated Building)

  • 윤제용;정우동;문성민;조민
    • 한국군사과학기술학회지
    • /
    • 제11권2호
    • /
    • pp.101-108
    • /
    • 2008
  • This study attempted to develop the technology by gaseous ozone for decontaminating building affected by a model of biological weapon agent(Bacillus subtilis spores) instead of Bacillus anthracis spore. The use of ozone is attractive method from a practical point of view of decontamination procedure since it has strong oxidation power but no residue after application. We examined the disinfection efficiency of gaseous ozone to Bacillus subtilis spores which suspension was sprayed on different material surfaces and dried. Three different types of gaseous ozone was applied : dry ozone, dry ozone with humidified air, and water bubbled wet ozone. Dry ozone(1500ppm) failed to achieve any significant inactivation for 2hrs. However, six log reduction of B. subtilis spore was achieved within 30min by 1500ppm of water bubbled wet ozone. This result shows the noticeable inactivation efficiency by gaseous ozone compared with previous studies. Good performance by wet ozone was also found for military material surface.(i.e. : gas mask hood, protective garments, army peinted metal surface).

코로나방전선 표면 산화에 따른 오존발생량의 경시특성 (Time Dependant Ozone Generation due to Oxidation of the Surface of Corona Discharge Wires)

  • 정성진;박승록;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.22-25
    • /
    • 2000
  • Time dependent ozone generation characteristics of some oxide layers grown by ozone on the surface of corona discharge wires have been investigated experimentally in air ambience. Four wires of stainless steel, iron, silver and copper were used for the corona discharge wire of an ozone generator. And the effect of the metal oxide layers on ozone generation was studied and the contamination morphology of each layers was characterized. With the SEM images and the EDS spectra, it was found that all the surface of the corona wire were oxidized by the generated ozone and contaminated by airborne particles through the gradient force. As a result, the morphology and the electrical property of metal oxide layer grown on corona wire surface influenced on ozone generation characteristics i.e. discharge mechanisms.

  • PDF

디젤 오염토양에서 화학적 산화에 의한 PAH 분해특성 및 PAH 분해미생물의 거동

  • 정해룡;안영희;김인수;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.22-25
    • /
    • 2002
  • The effect of in-situ chemical oxidation on the indigenous soil microorganisms (total microbes and PAH-degrading microbes) and contaminant removal were investigated. Field soil contaminated with diesel in gas station was collected and the soil was treated from 0 to 900 minutes by in-situ ozonation as chemical remediation. The treated soil samples were incubated with supplying oxygen during the 9 weeks to understand the characteristics of microbes regrowth, damaged by ozone. The sharp decrease of aromatic fraction and TPH was observed within 60 minutes of ozone application and aromatic fraction and TPH then slowly decreased. The phenanthren-degrading bacteria were the most sensitive to ozonation, because 1 hour of ozonation reduced the microbes from 10$^{6}$ CFU/g-soil to below detection limits.

  • PDF

산업단지내 독성유기화합물 및 중금속으로 오염된 토양의 정화복원기술 상용화 연구

  • 김수곤;손규동;박지연;최희철;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.31-34
    • /
    • 2004
  • Feasibility of electrokinetic(EK)-Fenton process and Ozone chemical oxidation were investigated for tile removal of organic contaminants and heavy metals from the contaminated soil. In EK-Fenton process, accumulated electroosmotic flow(EOF) was 80 L for 26 days. Removal efficiency of TPH, As, and Ni were 61%, 36%, and 47%, respectively. The concentration of As was high near the anode due to the transport of anionic As toward the anode, while the concentration of Ni was high near the cathode by the movement of cationic Ni to the cathode. Field scale application of in-situ ozonation was carried out for removal of TPH in 3-D test cell (3 m$\times$2 m$\times$2 m). After 25 days of ozone injection, more than 80% of removal rate was observed through the test cell.

  • PDF

브롬촉매와 암모니아의 오존산화 반응시 pH의 영향에 관한 연구 (The Effect on the pH in ozonation of ammonia with Br catalysis)

  • 박문숙;안재동;노봉오
    • 환경위생공학
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2004
  • This study was conducted to supply basic informations on development of water treatment process for the ozonation of ammonia depend on pH variation with or without bromide catalysis. The results were as follows: The oxidation rate of ammonia increased depend on pH increase at ozone/bromide process. It was found that overall kinetics was zero order with respect to reaction time and reaction velocity constant of zero order increased depend on pH increase from 4.9 to 9.5 and the equation of linearization was $k_{o}$ = 0.00565 ${\times}$ [pH] + 0.0069 at ozone/bromide process. The denitrification reaction of ammonia was superior as the pH increase in the presence of bromide.

유류오염토양 복원을 위한 지중 오존산화기술의 현장규모 적용

  • 정해룡;손규동;최희철;김수곤;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.172-175
    • /
    • 2003
  • Field scale application of in-situ ozonation were carried out for remediation of variably saturated soils contaminated with diesel fuel with 3 dimensional test cell (3m$\times$2m$\times$2m). After 20 days of ozone injection, more than 90% of removal rate was observed through the 3-D test cell. This result might be caused by uniform distribution, relatively low oxidant demand, and low water content of soils, as well as high oxidation potential of ozone. However, less than 50 % of injected ozone was monitored through the 3-D test cell even after 20 days of injection.

  • PDF