• Title/Summary/Keyword: ozone monitoring

Search Result 174, Processing Time 0.019 seconds

Feasibility Study for Derivation of Tropospheric Ozone Motion Vector Using Geostationary Environmental Satellite Measurements (정지궤도 위성 대류권 오존 관측 자료를 이용한 대류권 이동벡터 산출 가능성 연구)

  • Shin, Daegeun;Kim, Somyoung;Bak, Juseon;Baek, Kanghyun;Hong, Sungjae;Kim, Jaehwan
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1069-1080
    • /
    • 2022
  • The tropospheric ozone is a pollutant that causes a great deal of damage to humans and ecosystems worldwide. In the event that ozone moves downwind from its source, a localized problem becomes a regional and global problem. To enhance ozone monitoring efficiency, geostationary satellites with continuous diurnal observations have been developed. The objective of this study is to derive the Tropospheric Ozone Movement Vector (TOMV) by employing continuous observations of tropospheric ozone from geostationary satellites for the first time in the world. In the absence of Geostationary Environmental Monitoring Satellite (GEMS) tropospheric ozone observation data, the GEOS-Chem model calculated values were used as synthetic data. Comparing TOMV with GEOS-Chem, the TOMV algorithm overestimated wind speed, but it correctly calculated wind direction represented by pollution movement. The ozone influx can also be calculated using the calculated ozone movement speed and direction multiplied by the observed ozone concentration. As an alternative to a backward trajectory method, this approach will provide better forecasting and analysis by monitoring tropospheric ozone inflow characteristics on a continuous basis. However, if the boundary of the ozone distribution is unclear, motion detection may not be accurate. In spite of this, the TOMV method may prove useful for monitoring and forecasting pollution based on geostationary environmental satellites in the future.

A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate (오존 간이측정기에 대한 연구(I)-필터의 민감도)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

A Study on the Characteristics of Rural and Urban Surface Ozone Conentrations (청정지역과 도시지역의 오존농도 특성 연구)

  • 서명석;박경윤;이호근;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.253-262
    • /
    • 1995
  • A study has been performed on the characteristics of rural and urban surface ozone concentration for the period of March 1992 to February 1993. The monitoring station of rural ozone is located at Kosan, Cheju and other urban monitoring stations are located at Seoul, Pusan and Kwangju. Rural's and urban's ozone data exhibit a distinct features in many ways. First, annual mean of rural ozone concentration os very high(42 ppbv) but urban's are very low(10 .sim.15 ppbv). Second, rural ozone data shows a seasonal variation with it's maximum in spring, and minimum in summer, but urban's show a seasonal variation with it's maximum in spring, and minimum in winter. Third, diurnal variation of rural data is very small but that of urban's are very large. Fourth, urban's data are extremely low(< 3 ppbv) and have no seasonal variations.

  • PDF

Monitoring and Long-term Trend of Total Column Ozone from Dobson Spectrophotometer in Seoul (1985~2017) (돕슨 분광광도계를 이용한 서울 상공의 오존층 감시 및 장기변화 경향(1985~2017))

  • Park, Sang Seo;Cho, Hi Ku;Koo, Ja-Ho;Lim, Hyunkwang;Lee, Hana;Kim, Jhoon;Lee, Yun Gon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.13-20
    • /
    • 2019
  • Since 1985, the Dobson Spectrophotometer has been operated at Yonsei University, and this instrument has monitored the daily representative total ozone in Seoul. Climatological value for total ozone in Seoul is updated by using the daily representative observation data from 1985 to 2017. After updating the daily representative total ozone data, seasonal and inter-annual variation of total ozone in Seoul is also estimated after calculating inter-comparison between ground (Dobson Spectrophotometer) and satellite [Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI)] observations. The global average of total ozone measured by satellite is 297 DU, and its recent amount is about 3.5% lower than the global amount in 1980s. In Seoul, daily representative total ozone is ranged from 225 DU to 518 DU with longterm mean value of 324.3 DU. In addition, monthly mean total ozone is estimated from 290 DU (October) to 362 DU (March), and yearly average of total ozone have been continuously increased since 1985. For the long-term trend of total ozone in Seoul, this study is considered the seasonal variation, Solar Cycle, and Quasi-Biennial Oscillation. In addition to the natural oscillation effect, this study also considered to the long-term variation of sudden increase of total ozone due to the secondary ozone peak. By considering these natural effects, the long-term total ozone trends from 1985 to 2017 are estimated to be 1.11~1.46%/decade.

A Study on Allocation of Air Pollution Monitoring Network by Spatial Distribution Analysis of Ozone and Nitrogen Dioxide Concentrations in Busan (부산지역 오존 및 이산화질소 농도의 공간분포해석에 따른 대기오염측정망 배치연구)

  • Yoo, Eun-Chul;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.583-591
    • /
    • 2004
  • In this study, methodologies for the rational organization of air pollution monitoring network were examined by understanding the characteristics of temporal and spatial distribution of secondary air pollution, whose significance would increase hereafter. The data on $O_3$ and $NO_2$ concentrations during high ozone period in 1998~1999 recorded at the nine air pollution monitoring station in Busan were analysed using principal component analysis (PCA) and cumulative semivariogram. It was found that the ozone concentration was deeply associated with the daily emission characteristics or the $O_3$ precusors, and nitrogen dioxide concentration largely depends on the emission strength of regional sources. According to the spatial distribution analysis of ozone and nitrogen dioxide in Busan using cumulative semivariograms, the number of monitoring stations for the secondary air pollution can be reduced in east-west direction, but reinforced in north-south direction to explain the spacial variability. More scientific and rational relocation of air pollution monitoring network in Busan would be needed to investigate pollution status accurately and to plan and implement the pollution reduction policies effectively.

A Study of Ozone Variations in a Semiconductor Fabrication Facility and Office Related to the Ozone Concentration in the Outdoor Air (외기 오존 농도에 따른 반도체 작업환경 및 사무실에서의 오존 농도 변화 연구)

  • Lee, Ji-Eun;Jung, Myung-Koo;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.188-197
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.

Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea (고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화)

  • 김유라;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

Analysis of Time Series Models for Ozone at the Southern Part of Gyeonggi-Do in Korea (경기도 남부지역 지표오존농도의 시계열모형 연구)

  • Lee, Hoon-Ja
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.364-372
    • /
    • 2007
  • The ozone concentration is one of the important environmental issue for measurement of the atmospheric condition of the country. In this article, two time series ARE models, the direct ARE model and applied ARE model have been considered for analyzing the ozone data at southern part of the Gyeonggi-Do, Pyeongtaek, Osan and Suwon monitoring sites in Korea. The result shows that the direct ARE model is better suited for describing the ozone concentration in all three sites. In both of the ARE models, eight meteorological variables and four pollution variables are used as the explanatory variables. Also the high level of ozone data (over 80 ppb) have been analyzed at the Pyeongtaek, Osan and Suwon monitoring sites.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

Studies of High-Ozone Episodes in the Greater Seoul Area between 1990 and 1997 (1990~1997 기간 중 서울.수도권 지역의 고농도 오존 사례 연구)

  • 김영성;오현선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.267-280
    • /
    • 1999
  • To investigate the characteristics of high-ozone occurrences in the Greater Seoul Area(GSA), three high-ozone episodes were selected, for which the ozone warning for concentration above 120 ppb might be issued. The selection was on the basis of morning wind directions and speeds, and daily maximum ozone concentrations measured between 1990 and 1997. The episodes chosen to meet selection criteria were seven days in July 1992, nine days in July 1994, and three days in August 1994, as respectively characterized by southwesterly, easterly, and calm winds in the morning. However, more than 80% of high-ozone days in the GSA were associated with calm winds and the concomitant accumulation of local emission in the morning, rather than being due to transport of ozone or its precursors. This is believed to be the primary reason why ozone concentrations in the GSA varied in a completely different manner even between adjacent monitoring stations. Several premises for initiating research studies for resolving these local variations of ozone concentrations in the GSA are also discussed.

  • PDF