• 제목/요약/키워드: ozone in Korea

검색결과 772건 처리시간 0.03초

The Use of Chemical Additives to Protect SBS Rubbers Against Ozone Attack

  • Moakes, C.A.
    • Elastomers and Composites
    • /
    • 제34권2호
    • /
    • pp.177-182
    • /
    • 1999
  • SBS thermoplastic elastomers offer an inexpensive alternative to vulcanised rubbers for many undemanding applications. They are, however, particularly susceptible to attack from atmospheric ozone leading to cracking as soon as any strain is applied. In most rubber applications some strain is unavoidable. In this paper a compounding approach to protecting SBS thermoplastic rubbers against ozone is described. An explanation is offered for why a protective effect Is observed only when certain combinations of additive are used. SBS elastomers are the most affordable class of thermoplastic rubbers. To achieve finished products resistant to ozone and without compromising the light colours often demanded, recourse must be made to blending with other saturated elastomers or replacement by hydrogenated (SEBS) types. The latter is a significantly more expensive alternative. Under laboratory conditions where the rate of ozone attack is increased by several decades, unprotected SBS begins to crack within a few hours. Several different protective agents are examined here, the best of which, a cyclic enol ether, $Vulkazon^{(R)}$ AFD, can extend the resistance to any cracking to several weeks by the use of a few percent by weight of additive. The systems reported neither discolour the polymer nor stain other materials with which it may be in contact. Use of the protective systems described here could enable SBS elastomers to compete in many applications with the more expensive SEBS polymers.

  • PDF

탄소나노튜브를 이용한 하이브리드 내오존성 코팅 막의 제조 및 특성 (Preparation and Characterization of Hybrid Ozone Resistance Coating Film Using Carbon Nanotube)

  • 김성래;이상구;양정민;이종대
    • 폴리머
    • /
    • 제38권5호
    • /
    • pp.573-579
    • /
    • 2014
  • 탄소나노튜브(CNT), 불소계 아크릴레이트 2,2,2-trifluoroethylmethacrylate(3FMA) 및 유-무기 조성비와 같은 합성조건을 달리하여 제조된 자외선 경화형 유-무기 하이브리드 코팅 막의 표면특성 및 내오존성에 대해 연구하였다. 코팅 막은 금속 알콕사이드 전구체인 tetraethoxysilane(TEOS)와 실란 커플링제인 methacryloyloxypropyltrimethoxysilane (MPTMS)로 구성된 유-무기 혼성 용액에 탄소나노튜브 및 3FMA와 자외선 경화를 위한 유기물을 첨가하여 제조된 코팅제를 자외선 경화시켜 제조하였다. 제조된 코팅 막의 내오존성 및 기재와의 접착력은 TEOS, 3FMA 및 CNT의 함량에 크게 영향을 받는다는 것을 확인하였다. 특히, 탄소나노튜브가 첨가된 코팅 막은 우수한 내오존성 및 접착력 뿐만 아니라 높은 표면경도를 나타내었다. TEOS의 경우, 함량이 증가할수록 표면경도 및 내오존성은 향상되었지만, 기재와의 접착력은 감소되었다. 불소아크릴레이트 3FMA의 경우, 함량이 증가할수록 내오존성은 향상되었지만 표면경도는 감소하였다.

Degradation and Neutralization of Total Residual Oxidant (TRO) in the Treated Ballast Water by Ozonation

  • Park, Sung-Jin;Bin, Jung-In;Lee, Eon-Sung;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.399-406
    • /
    • 2010
  • The aims of this study are to provide data on the ozone dosage control system and TRO sensor performance, to assess the performance of the degradation of total residual oxidant (TRO) neutralizer and to provide data on degradation rates of TRO in the ballast tanks, following treatment by the Ozone BWTS. This study includes the results of an evaluation of the TRO neutralizer, which was tested on the test barge. Accordingly, it has undertaken the evaluation of TRO degradation rates following treatment by the Ozone BWTS.

Assessment on the Variability of Total Ozone for Climate Change over Korea

  • Moon, Yun-Seob;Shin, Hye-Jung;Oh, Sung-Nam;Park, Byoung-Cheol;Chung, Hyo-Sang;Kim, Yoo-Keun;Kim, Seong-Kyoun
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.39-42
    • /
    • 2002
  • Ozone is one of the most significant atmospheric constituents controlling the intensity of solar UV-B irradiance (280 to 320nm), and the decrease of the total ozone amount supported by ozonesondes and spectrometers will result in the increase of UV-B irradiance at the earth's surface. For example, 1% decrease in stratospheric ozone is expected to yield a 2-3% increase in UV-B irradiance and in the incidence of skin cancer. (omitted)

  • PDF

정수장의 무성방전형 오존발생기 최적활용방안에 관한 연구 (A Study on the Optimal Use of Silent Discharge Type Ozonizer in Purification Plant)

  • 신홍섭;박현미;권영학;송현직;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.54-60
    • /
    • 2015
  • There are 5 purification plants with the adopted advanced water purification treatment process in Korea. Annual operating costs were 8,990 million won including purchase cost of oxygen and power usage charges. We need research to optimize, in the future, when considering the direction of domestic water treatment continues to adopt advanced water treatment process. In this paper, calculate the optimal operating costs by injected the oxygen gas, used power cost. approximately 25% of the operating costs can be reduced when injected the ozone gas is 1.0ppm than 2.0ppm, the necessary amount of oxygen is increased then power is lower. so operating costs are decided according to oxygen costs. On the other hand, high ozone concentration 2.0ppm, the necessary power is increased then amount of oxygen is lower. Therefore, in the case of G purification plant, the controlling factor of the input ozone concentration 2ppm, PID control operation by setting the concentration of over 10Wt% is efficient. The installed capacity is the more little the more better when considering on Ozone injection rate in the process of water treatment.

Installing Ozone Bleaching and Hot Acid Treatment at NPI Mills

  • Uno, Shunichiro;limori, Takeshi
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.325-329
    • /
    • 2006
  • Nippon Paper Industries, Co., Ltd. declared conversion of all the bleaching process to ECF, and most of the production had converted by now. To reduce ECF bleaching cost, we found that depending on electricity supply condition of the mill, utilization of ozone bleaching could be very effective. In addition, hot acid treatment of unbleached pulp also seemed to be effective for hardwood. In this study, several conditions for each technology were examined with the pulps from our own mills to reduce bleaching cost and to keep fiber quality acceptable level. In hot acid treatment study, with mild conditions (temperature lower than $90^{\circ}C$), sufficient reduction in Kappa number and hexenuronic acids content of the pulp were observed, while pulp viscosity was maintained. Moreover, to maintain strength of bleached pulp that subjected both to ozone bleaching and hot acid treatment, recommended Kappa number after ozone bleaching was more than 3. Based on these findings, two of our mills had installed medium-consistency ozone bleaching facilities and three mills installed hot acid treatment. Especially in Yatsushiro mill, both were installed in one bleaching line (A-ZD-E/P-D sequence), and running successfully.

  • PDF

위성 기반 HCHO/NO2 비율을 통한 국내 대류권 오존 민감도 특성 분석 (Characteristic Analysis of Tropospheric Ozone Sensitivity from the Satellite-Based HCHO/NO2 Ratio in South Korea)

  • 장진아;이윤곤;유정아;성경희;김상민
    • 대한원격탐사학회지
    • /
    • 제39권5_1호
    • /
    • pp.563-576
    • /
    • 2023
  • 본 연구에서는 대류권 오존과 전구체인 nitrogen oxides (NOx), volatile organic compounds (VOCs)의 광화학반응 관계를 살펴보고자, Ozone Monitoring Instrument (OMI)와 TROPOspheric Monitoring Instrument(TROPOMI)의 nitrogen dioxide (NO2), formaldehyde (HCHO), OMI/Microwave Limb Sounder (MLS) tropospheric column ozone (TCO), Airkorea 지상측정 ozone (O3) 자료를 분석하였다. OMI 위성자료를 이용하여 2006년부터 2020년까지 장기 변화 경향을 살펴보면 TCO는 동북아시아 지역 전체적으로 증가하는 추세를 보였으며, NO2는 꾸준히 감소하고 HCHO는 계속해서 증가하는 경향성을 보였다. 또한 오존 민감도의 지표인 formaldehyde nitrogen dioxide ratio (FNR)은 점점 증가하고 있으며, 이는 VOC-limited 영역이 감소하고 있음을 의미한다. 본 연구는 한국 지역 오존의 지속적인 증가 원인을 밝히기 위해서 최근 4년 기간(2019~2022년)의 TROPOMI FNR과 지상 측정 O3를 이용하여 국내 오존 생성 민감도 분석을 진행하였다. 기존 선행연구들과 동일하게 국내 대도시 지역에서 VOC-limited 및 Transitional 영역이 나타났으며, 그 외에도 국내 주요 발전소가 위치한 지역에서 VOC-limited 영역이 나타났다. VOC-limited 영역, 즉 NOx가 과도하게 포화되어 있는 영역에서는 NOx 배출 감소가 오히려 적정 반응을 약화시켜 국내 오존 농도 증가를 유도했을 것으로 판단된다. 따라서 VOC-limited 영역이 나타나는 지역에서 오존 농도를 감소시키기 위해서는 NOx의 배출보다 단기적으로 VOC 배출을 감소시켜야 함을 시사한다.

색도물질과 옥살산의 오존분해를 위한 고효율 Jet Loop 반응기의 적용 (Application of High-performance Jet Loop Reactor for the Decolorization of Reactive black 5 and Mineralization of Oxalic Acid by Ozone)

  • 변석종;;;조순행;윤제용;김수명
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.78-85
    • /
    • 2004
  • As an ozone contactor, we newly adopted HJLR (High-performance Jet Loop Reactor) for the decolorization of Reactive black 5 and the mineralization of oxalic acid, which has been applied exclusively in biological wastewater treatments and well-known for high oxygen transfer characteristics. The ozonation efficiency for organic removals and ozone utilization depending on the mass transfer rate were compared to those of Stirred bubble column reactor, which was controlled by varing energy input in the HJLR and Stirred bubble column reactor. The results were as follows; first, the decolorization rate of Reactive black 5 in the HJLR reactor was nearly proportional to the increasing $k_La$. When the $k_La$ was increased by 25 % from $13.0hr^{-1}$ to $16.4hr^{-1}$, 30 % of the k' (apparent reaction rate constant) was increased from 0.1966 to $0.2665min^{-1}$ (Stirred bubble column; from 0.1790 to $0.2564min^{-1}$). Ozone transfer was found to be a rate-determining step in decolorizing Reactive black 5, which was supported by that no residual ozone was detected in all of the experiments. Second, the mineralization of oxalic acid was not always proportional to the increasing $k_La$ in the RJLR reactor. The rate-determining step for this reaction was OH(OH radical) production with ozone transfer, because residual ozone was always detected during the ozonation of oxalic acid in contrast with Reactive black 5. This result indicates that the increase of $k_La$ in the HJLR reactor is beneficial only when there are in ozone transfer limited regions. In addition, regardless of $k_La$, the mineralization of oxalic acid was nearly accomplished within 60 minutes. It was interpreted as that the longer staying of residual ozone by whirling liquid in the HJLR reactor contributed to an high ozone utilization(83-94%), producing more OR radicals.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발 (Development of an ionic wind dust collector towards coronavirus reduction in subway stations)

  • 신동호;김영훈;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.