• 제목/요약/키워드: ozone emission rate

Search Result 20, Processing Time 0.023 seconds

Sensitivity of Ozone to NOx and VOCs in a Street Canyon (도로 협곡에서 NOx와 VOCs에 대한 오존의 민감도)

  • Lee, Kwang-Yeon;Kwak, Kyung-Hwan;Park, Seung-Bu;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.307-316
    • /
    • 2013
  • The sensitivity of ozone to $NO_x$ and volatile organic compounds (VOCs) emission rates under different ventilation rates and $NO_2-to-NO_x$ emission ratios in a street canyon is investigated using a chemistry box model. The carbon bond mechanism IV (CBM-IV) with 36 gaseous species and 93 chemical reactions is incorporated. $NO_x$ and VOCs emission rates considered range from 0.01 to $0.30ppb\;s^{-1}$ with intervals of $0.01ppb\;s^{-1}$. Three different ventilation rates and three different $NO_2-to-NO_x$ emission ratios are considered. The simulation results show that the ozone concentration decreases with increasing $NO_x$ emission rate but increases with increasing VOCs emission rate. When the emission ratio of VOCs to $NO_x$ is smaller than about 4, the ozone concentration is lower in the street canyon than in the background. On average, the magnitude of the sensitivity of ozone to $NO_x$ emission rate is significantly larger than that to VOCs emission rate. As the $NO_x$ emission rate increases, the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates decreases. Because the ozone concentration is lower in the street canyon than in the background, the increased ventilation rate enhances ozone inflow from the background. Therefore, the increase in ventilation rate results in the increase in ozone concentration and the decrease in the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates when the emission ratio of VOCs to $NO_x$ is smaller than about 4. On the other hand, the increase in $NO_2-to-NO_x$ emission ratio results in the increase in ozone concentration because the chemical ozone production due to the $NO_2$ photolysis is enhanced. In the present experimental setup, the contribution of the change in $NO_2-to-NO_x$ emission ratio to the change in the sensitivity of ozone to $NO_x$ emission rate is larger than that of the change in ventilation rate.

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Numerical Study on the Process Analysis of Ozone Production due to Emissions Reduction over the Seoul Metropolitan Area (수도권 배출량 저감에 따른 오존 발생 과정 분석에 관한 수치연구)

  • Jeong, Yeo-Min;Lee, Soon-Hwan;Lee, Hwa-Woon;Jeon, Won-Bae
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.339-349
    • /
    • 2012
  • In order to clarify the impact of emissions reductions on the air quality over Metropolitan area of Korean Peninsula, several numerical experiment and analysis of integrated process rate(IPR) of ozone were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. As result in the sensitive test of VOC/NOx reduction experiments, although VOC reduction tends to induce the different impact on the advection and photochemical reaction rate of ozone in urban area and rural area, the mechanism of ozone appeared to be more sensitive to the reduction of VOC than that of NOx over the metropolitan and its surround area. So the control of VOC emission inventories is an effective means to decrease the ozone concentrations around this area.

Boundary Layer Ozone Transport from Eastern China to Southern Japan: Pollution Episodes Observed during Monsoon Onset in 2004

  • Pochanart, Pakpong;Wang, Zifa;Akimoto, Hajime
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.48-56
    • /
    • 2015
  • The trajectory analysis of boundary layer ozone data at four regional sites in the East Asian outflow regions in Japan was carried out together with boundary layer ozone data observed at Mt. Tai and Mt. Huang in the source region of central eastern China during the monsoon onset in May-June 2003 and 2004. At all sites, the influences of anthropogenic emissions from East Asia have been found. During May and June 2004, the evidences of direct pollution transport from central eastern China to Hedo, an outflow site in Okinawa Island were observed. Ozone mixing ratios associated with air masses from central eastern China averaged 45 ppb while those associated with clean air masses from the Pacific were only 14 ppb, which resulted in averaged 31 ppb increase of ozone mixing ratios during the pollution episodes from central eastern China at Cape Hedo. Using transport time analysis and averaging all ozone episodes transported from central eastern China, the ozone dilution rate of 5.4 ppb per day was roughly estimated during air masses transported from source to outflow regions at Hedo. In the regions nearby Japanese mainland, however ozone increases by long-range transports were more related to both domestic and East Asian sources as a whole.

A Study of Nitrous Oxide Thermal Decomposition and Reaction Rate in High Temperature Inert Gas (고온 불활성 기체 분위기에서 아산화질소 열분해 및 반응속도에 관한 연구)

  • Lee, Han Min;Yun, Jae Geun;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.25 no.3
    • /
    • pp.132-138
    • /
    • 2020
  • N2O is hazardous atmosphere pollution matter which can damage the ozone layer and cause green house effect. There are many other nitrogen oxide emission control but N2O has no its particular method. Preventing further environmental pollution and global warming, it is essential to control N2O emission from industrial machines. In this study, the thermal decomposition experiment of N2O gas mixture is conducted by using cylindrical reactor to figure out N2O reduction and NO formation. And CHEMKIN calculation is conducted to figure out reaction rate and mechanism. Residence time of the N2O gas in the reactor is set as experimental variable to imitate real SNCR system. As a result, most of the nitrogen components are converted into N2. Reaction rate of the N2O gas decreases with N2O emitted concentration. At 800℃ and 900℃, N2O reduction variance and NO concentration are increased with residence time and temperature. However, at 1000℃, N2O reduction variance and NO concentration are deceased in 40s due to forward reaction rate diminished and reverse reaction rate appeared.

Effect of Microbubble Ozonation Process on Performance of Biological Reactor System for Excess Sludge Solubilisation (마이크로버블오존을 이용한 잉여슬러지 가용화 처리가 생물반응조의 성능에 미치는 영향)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • The study purpose was to examine an effect of zero emission of excess sludge on biological reactor and treated water quality within the biological reactor in the process of biological treatment combined with excess sludge reduction system with ozone. Under an ozone injection rate 0.03 g $O_3/g$ SS, Sludge Disintegration Number (SDN) 3 and less than pH 4 as pre-treatment process, it was possible to maintain a stable biological treatment process without sludge disintegration. In the test of $OUR_{max}$, of sludge, its value was hardly under the condition of ozone injection rate 0.03 g $O_3/g$ SS. There were almost no changes of MLVSS/MLSS within biological reactor followed by a solubilization of excess sludge. Accumulation of microorganism within biological reactor was also not observed. After solubilization of excess sludge, an increase for organic matter and SS concentrations of an effluent was not observed and T-N concentration was reduced by increasing nitrification and denitrification rate within biological reactor. Most of T-P was not removed by zero emission of excess sludge and was leaked by being included in effluents.

Emission Estimation and Exposure to Hazardous Gaseous Pollutants Associated with Use of Air Fresheners Indoors (실내 방향제 사용에 의한 유해 가스상 오염물질 배출 산정 및 노출 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Kwon, Gi-Dong;Lee, Jong-Hyo
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.2
    • /
    • pp.137-148
    • /
    • 2009
  • This study quantitatively investigated the emissions of indoor air pollutants associated with the utilization of air fresheners indoors, and evaluated individual exposure to five specified indoor air pollutants, which were chosen on the basis of selection criteria. An electrically-polished stainless steel chamber (50L) was employed to achieve this purpose. Test air fresheners were selected through three steps: first, on the basis of market sales; second, on the basis on a preliminary head-space study; and lastly, on the basis of emissions of toxic compounds (benzene, ethyl benzene, limonene, toluene, and xylene). The empirical mathematical model fitted well with the time-series concentrations in the environmental chamber (in most cases, determination coefficient, $R^2{\gtrsim}$0.9), thereby suggesting that the empirical model was suitable for testing emissions. The concentration equilibrium appeared 180 min after the introduction of sample air fresheners into the chamber. Both the chamber concentrations of emission rates or factors varied greatly according to air freshener type. It is noteworthy that although benzene, ethyl benzene, toluene, and xylene were emitted from all test air fresheners, their exposure levels were not significant enough to result in any significant health risk. However, certain type of air fresheners were observed to emit significant amount of limonene, which is potentially reactive with ozone to generate secondary pollutants with oxidants such as ozone, hydroxyl radicals, and nitrogen oxides. The exposure levels to limonene associated with the utilization of three air fresheners were estimated to be 13 to 175 times higher than that of other air fresheners. This information can help consumers to select low-pollutant-emitting air fresheners.

Simultaneous Application of Platinum-Supported Alumina Catalyst and Ozone Oxidant for Low-temperature Oxidation of Soot (백금담지 알루미나 촉매와 오존 산화제 동시 적용에 의한 탄소 입자상 물질의 저온 산화반응)

  • Lee, Jin Soo;Lee, Dae-Won
    • Korean Chemical Engineering Research
    • /
    • v.56 no.5
    • /
    • pp.752-760
    • /
    • 2018
  • The lowering of temperature for combustion of diesel particulate matters (or diesel soot) is one of the important tasks in automotive industry that is searching for a way to meet up "high-fuel efficiency, low-emission" standard. In this study, it was discussed how the use of ozone over platinum-based catalyst promotes a low-temperature soot oxidation occurred at $150^{\circ}C$. The use of platinum catalyst did not increase oxidation rate largely but was very effective in improving the selectivity of carbon dioxide. The pre-oxidation of NO into $NO_2$ using ozone was rather crucial in improving the oxidation rate of soot at $150^{\circ}C$.

A Study on the Solubilisation of Excess Sludge using Microbubble Ozone (잉여슬러지 가용화를 위한 마이크로버블 오존 이용에 관한 연구)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.325-332
    • /
    • 2010
  • This study was conducted with the experiment of solubilisation of excess sludge by microbubble ozone process. To improve ozone contact efficiency, microbubble ozones which its diameter were the avearge 30 ${\mu}m$, microbubble size less than 40 ${\mu}m$ occupied about over 90% of all. In treating sludge using microbubble ozones, in case microbubble ozones are injected at microbubble ozone dosage of 0.34 g $O_3/g$ SS or less regardless of sludge concentration, microbubble ozone consumption rate was found to be 100% with no emission of waste ozones. In treating sludges by each concentration, in case the initial SS concentration of sludge is set to 6,447 mg/L, 5,557 mg/L, 3,180 mg/L, 1,092 mg/L and 515 mg/L, the amount of removed SS tended to increase with increase in initial SS concentration for the same microbubble ozone dosage, and treatment of sludge with high initial SS concentration was effective in raising the oxidation efficiency of microbubble ozones. On the other hand, as a result of reviewing acid, alkali and microbubble ozone treatment as composite treatment of sludge, use of acid treatment for the pre-treatment of microbubble ozone was more effective than alkali treatment, and in case of treatment at microbubble ozone dosage 0.05g $O_3/g$ SS with the concentration of sulfuric acid infused in the sludge, the amount of removed SS, 153.9 g, was 1.9 times more than 81.2 g the amount of single treatment of microbubble ozone.