• Title/Summary/Keyword: ozone and temperature

Search Result 361, Processing Time 0.031 seconds

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.

TEMPERATURE AND PRESSURE DEPENDENCES ON THE ISOTOPIC FRACTIONATION EFFECT IN THE THERMAL DECOMPOSITION OF OZONE (오존의 열분해 시 나타나는 동위원소 분할효과의 온도와 압력의 의존성에 관한 연구)

  • 김수주;양종만
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.297-311
    • /
    • 1997
  • To understand the mass-independent isotopic fractionation effects, thermal decomposition of ozone was performed. Initial oxygen gas was converted to ozone completely. Then, the ozone was decomposed to oxygen at various temperatures ($30~150^{\circ}C$). Isotopic compositions of product oxygen and residual ozone were measured using a stable isotope mass spectrometer. The experimental results were compared with the studies which were performed at the similar conditions. From the raw experimental data, the functions of the instantaneous fractionation factors were calculated by the least square fit. The results clearly showed the temperature dependence. They also showed the pressure dependence and the surface effect. This study may play an important role in the study of ozone decomposition mechanism. It can be applied to explain the mass-independent isotopic pattern found in stratospheric ozone and in meteorites.

  • PDF

New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

Measutements of the ground-level ozone in a rural area of Chongwon, Korea (충북 청원군에서 관측된 지표면 부근의 오존)

  • 윤마병;정용승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.85-93
    • /
    • 1995
  • Measurements of ground level ozone concentrations were made in a rural area of Chongwon (Choongbook Province) from June 1993 to July 1994. High values frequently exceeding 100 ppb (ambient air qualyty standard of Korea) were recorded. High ozone concentrations in the boundary layer were primarily correlated with the several meteorological parameters in warm seasons: pressure, radiation, temperature, precipitation and wind velocity. The annual average concentration of ozone at Chongwon was 17ppb, and this value was relatively higher than those for other cities in Korea. O$\_$3/ concentrations were observed to increase when the ridge of a surface anticyclone was passing over the region, and maximum values(.geq.100 ppb) were observed on the rear sides of high pressure centers and in the warm sectors of cyclones(well head of cold fronts). The ozone concentrations had a negative correlation with the concentration of primary pollutants(e.g., total hydrocarbons).

  • PDF

A Study on Ozone Passive Sampler (II) -Interference and Field Application (오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성)

  • Jeong, Sang-Jin;Yang, Hee-Jun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.

The Characteristics of Temporal and Spatial Distribution of Surface Ozone Concentration in Jeju Island (제주지역 지표 오존 농도의 시.공간적 분포 특성)

  • Lee, Gi Ho;Kim, Dae Jun;Heo, Cheol Gu
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.377-387
    • /
    • 2004
  • This study has been performed to clarify the characteristics of temporal and spatial distribution of surface ozone concentration over Jeju Island, one of the cleanest areas in Korea with low emissions of air pollutants. Ozone data are monitored at four sites in Jeju Island. These monitoring sites are located at two urban area(referred to Ido and Donghong), coastal area(Gosan site) and forest site(Chuna site). Ozone data has been routinely collected at these sites for the late four years. The patterns of seasonal cycle of ozone concentrations at all stations show the bimodal with the peaks on spring and autumn and a significant summer minimum. However, the patterns of diurnal variations at rural station, i.e., Gosan and Chuna sites are considerably different to those at urban stations such as Ido and Donghong sites. The patterns of $\DeltaO_3$ variations are very similar with those of monthly mean ozone concentrations and $\DeltaO_3$ values are exceeded 30 ppb, at urban stations. This may be that urban stations are more influenced by local photochemical reactions rather than rural stations. In order to assess the potential roles of meteorological parameters on ozone formation, the meteorological parameters, such as radiation, temperature, and wind are monitored together with ozone concentrations at all stations. The relationships of meteorological parameters to the corresponding ozone concentration are found to be insignificant in Jeju Island. However, at Gosan and Donghong stations, when the sea breeze blew toward the station, the ozone concentration is considerably increased.

Studies on the Behaviour of Ozone Concentration and the Influencing Factors (오존농도의 動態 및 影響因子에 關한 硏究)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

Temperature Dependence Characteristics of Double Cylindrical Type Ozonizer Using Spiral Type Internal Electrode (나선형 내부전극을 사용한 2중 원통형 오존발생기의 온도의존특성)

  • Chun, Byung-Joon;Lee, Sang-Keun;Rahman, Md. Fayzur;Lee, Dong-Heon;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2004-2006
    • /
    • 1999
  • In this paper, double Cylindrical type ozonizer has been designed and manufactured to improve ozone yield by cooling external electrode. The ozonizer equipped with three electrodes ( central, internal and external electrodes ). Discharge and ozone characteristics are described in this paper by varying the flow rate( Q ) of oxygen supplied gas, temperature of cooling gas and supplied voltage.

  • PDF

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

A study on high ozone concentration in Shiwha.Banwol industry complex using photochemical air pollution model- Analysis of meteorological characteristics - (시화.반월단지지역의 고농도 오존일에 대한 광화학모델 적용 연구 - 기상특성에 대한 분석 -)

  • An, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.47-59
    • /
    • 2011
  • The purpose of this paper is to simulate the high ozone concentration in Shiwha Banwol indusrial complex. High pollution episodes (ozone alert) of this area are the results of geographical location and its air pollutants emission. This research has used meteorological model (RAMS) and photochemical air pollution Model (CIT model). As first step of the evaluate of this combined model system simulations are done in terms of meteorological characteristics like wind fields, PBL-height, etc.. Numerical simulations are carried out with real meteorological synoptic data on June. 24-25, 2010. In comparison with real measurement and another research the model reflects well local meteorological phenomena and shows the possibility to be utilized to analyse the pollutant dispersion over irregular terrain region. The high ozone concentration is deeply correlated to the ambient air temperature, wind speed and solar radiation. Local meteorological phenomena like sea-land breeze impact on horizontal dispersion of ozone. This analysis of meteorological characteristics can, in turn, help to predict their influences on air quality and to manage the high ozone episodes.