• Title/Summary/Keyword: ozone and temperature

Search Result 361, Processing Time 0.031 seconds

Development of a Microplasma Source under Atmospheric Pressure using an External Ballast Capacitor (방전에너지 제어용 외부 커패시터를 이용한 대기압 마이크로 플라즈마 소스 개발)

  • Ha, Chang-Seung;Lee, Je-Hyun;Son, Eui-Jeong;Park, Cha-Soo;Lee, Ho-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.31-38
    • /
    • 2013
  • A pulse driven atmospheric plasma jet controlled by external ballast capacitor is developed. Unlike the most commonly use DBD sources, the proposed device utilizes bare metal electrode. The discharge energy per pulse can precisely be determined by changing voltage and capacitance of the ballast capacitor. It is shown that the device can provide wide range of plasma, from stable glow mode to near arc state. Current-voltage waveforms, optical emission spectra and discharge images are investigated as a function of an injection energy. The OES shows that He and oxygen lines are increased as a function of the external ballast capacitor. Ozone and rotational temperature have similar tendency with a power consumption. The feeding gas is He and the applied DC voltage is from 400V to 800V when the gap distance is $500{\mu}m$.

Characteristics of Fluorescent Organic Light Emitting Diodes using Amorphous IZO Anode Film (비정질 IZO 애노드를 이용한 형광 유기발광소자의 특성)

  • Moon, Jong-Min;Bae, Jung-Hyeok;Jeong, Soon-Wook;Kang, Jae-Wook;Kim, Han-Ki
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1044-1049
    • /
    • 2006
  • We reported on characteristics of the fluorescent OLED fabricated on commercial ITO/glass and BCS grown IZO/glass substrate, respectively. The amorphous IZO anode film grown by box cathode sputtering(BCS) exhibited similar electrical and optical characteristics to commercial ITO anode even though it was deposited at room temperature. In addition, the amorphous IZO anode showed higher workfunction (5.2 eV) than that of the commercial ITO anode (5.0 eV) after ozone treatment for 10 min. Furthermore, fluorescent OLED fabricated on amorphous IZO anode film showed improved current-voltage-luminance characteristics, external quantum efficiency and power efficiency en contrast with fluorescent OLED fabricated on commercial ITO anode film. It was thought that smooth surface and high workfunction of amorphous IZO anode lead to more efficient hole injection by reduction of interface barrier height between anode and organic layers.

The Study on Establishment of the Urban Atmospheric Environment Map for Analysis of Atmospheric Environment in Busan Metropolitan City (부산광역시 대기환경 파악에 활용가능한 도시대기환경지도 작성에 관한 연구)

  • Kim, Min-Kyoung;Jung, Woo-Sik;Lee, Hwa Woon
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.807-817
    • /
    • 2015
  • In this study the urban atmospheric environment map in Busan was made and it consist of the atmospheric environment element map and the atmospheric environment analysis map. The atmospheric environment element map covered the topography, the urban climate, the air pollutant emission, ozone and PM10 concentrations in Busan and the atmospheric environment analysis map included the thermal environment and the wind flow by using WRF meteorological numerical simulation. The meteorological elements from 2007 to 2011 in Busan were used in this study. As a result, in the center of Busan and Buk-gu along to the Nakdong river was the temperature high. To analyze the air flow of Busan 3 clusters depending on the wind direction were extracted with the cluster analysis. The results of the analysis on the detailed wind field of each cluster showed that the weak ventilation could be happened locally at the specific meteorological condition.

A study on the characteristics of evaporation heat transfer of carbon dioxide flowing upward in a vertical smooth tube (이산화탄소의 수직원관 내 상향유동 증발열전달 특성에 관한 연구)

  • Kim, Yong-Jin;Cho, Jin-Min;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2217-2221
    • /
    • 2007
  • Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical tube have been investigated by experiment. Before the test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. A smooth tube with outer diameter of 5 mm and length of 1.44 m was selected as a test tube. The test was conducted at mass fluxes of 212 to 530 kg/$m^2s$, saturation temperature of -5 to 20$^{\circ}C$, and heat fluxes of 20 to 45 kW/$m^2$. As the vapor quality and mass fluxes increase, the heat transfer coefficients of carbon dioxide are decreased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase.

  • PDF

Photo-grafting Dyeing of Wool Fabrics with ${\alpha}$-bromoacrylamide reactive dye (반응성 염료를 이용한 양모직물의 광그라프트 염색)

  • Dong, Yuanyuan;Jang, Jin-Ho
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.31-31
    • /
    • 2011
  • Lanasol dyes containing ${\alpha}$-bromoacrylamide or ${\alpha},{\beta}$-dibromopropionylamide group are used for wool dyeing. They are normally applied to wool under pH 4.5 to 6.5 at $100^{\circ}C$. Although wool fabric can be dyed to obtain deep colour, high light and wet fastness, the dyeing processes need long dyeing time at high temperature, with salt addition, which inevitably causes environmental problems. Grafting is a modification method for textile where monomers are covalently bonded onto the polymer chain. It can be initiated by ozone, ${\gamma}$ rays, electron beams, plasma, corona discharge and UV irradiation. Coloration by UV-induced photografting exhibits several advantages such as fast reaction rate, energy saving, simple equipment, easy exploitation and environmentally friendliness. Also it requires much lower energy compared to the conventional dyeing and less damage to the substrate. In this study, a direct sequential UV-induced photografting onto wool fabrics was discussed. To understand the graft polymerization mechanism further, several characterization methods were used. Moreover, the effects of several principal factors on the graft photopolymerization were investigated. Furthermore, the colorfastness results were compared with conventional dyeing methods.

  • PDF

Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube (수평 평활관내 R245fa의 흐름 응축 열전달 특성)

  • Park, Hyun-Shin;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.

An Experimental Study on Performance of Automotive Air conditioning System by using R-134a and R-152a (R-134a와 R-152a 냉매를 이용한 자동차용 에어컨 시스템의 성능에 관한 실험적 연구)

  • Kim, Jeong-Su;Lee, Dae-Woong;Yoo, Seong-Yeon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1225-1231
    • /
    • 2006
  • Recently, as the climate of temperature change has happened worldwide, To solve this problem, Kyoto protocol was taken to regulate global warming on Feb. 2005 and each country is making efforts to prevent global warming. In the automotive industry, R-134a refrigerant is widely used most these days because it has zero ODP(Ozone Depletion Potential). But R-134a GWP(Global Warming Potential) is so high. Therefore, replacement refrigerant desperately is needed as a alternative refrigerant. So, R-l52a is considered as one of the alternative refrigerants due to zero ODP and lower GWP against as required on Europe Committee. In this paper, performance of the air conditioning system between R-134a and R-152a is investigated experimentally. In the bench level, cooling capacity, condensing capacity, COP of automotive air conditioning system are ovaluated by means of air velocity entering the condenser and compressor revolution speed with optimized charge refrigerant quantity. Result of this study, R-152a refrigerant shows the possibility as alternative refrigerant of current R-134a in automotive air conditioning system.

  • PDF

Geochemistry of Total Gaseous Mercury in Nan-Ji-Do, Seoul, Korea (난지도 지역의 대기수은 지화학)

  • Kim, Min-Young;Lee, Gang-Woong;Shin, Jae-Young;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.611-622
    • /
    • 2000
  • To investigate the exchange rates of mercury(Hg) across soil-air boundary, we undertook the measurements of Hg flux using gradient technique from a major waste reclamation site, Nan-Ji-Do. Based on these measurement data, we attempted to provide insights into various aspects of Hg exchange in a strongly polluted soil environment. According to our analysis, the study site turned out to be not only a major emission source area but also a major sink area. When these data were compared on hourly basis over a full day scale, large fluxes of emission and deposition centered on daytime periods relative to nighttime periods. However, when comparison of frequency with which emission or deposition occurs was made, there emerged a very contrasting pattern. While emission was dominant during nighttime periods, deposition was most favored during daytime periods. When similar comparison was made as a function of wind direction, it was noticed that there may be a major Hg source at easterly direction to bring out significant deposition of Hg in the study area. To account for the environmental conditions controlling the vertical direction of Hg exchange, we compared environmental conditions for both the whole data group and those observed from the wind direction of strong deposition events. Results of this analysis indicated that the concentrations of pollutant species varied sensitively enough to reflect the environmental conditions for each direction of exchange. When correlation analysis was applied to our data, results indicated that windspeed and ozone concentrations best reflected changes in the magnitudes of emission/deposition fluxes. The results of factor analysis also indicated the possibility that Hg emission of study area is temperature-driven process, while that of deposition is affected by a mixed effects of various factors including temperature, ozone, and non-methane HCs. If the computed emission rate is extrapolated to the whole study area we estimate that annual emission of Hg from the study area can amount to approximately 6kg.

  • PDF

The Application of Humidity Indicators for Environmental Measurement Apparatus of Preservation Facility (문화재 보존시설에서의 습도지시카드 적용성 연구)

  • Lim, Bo-A;Shin, Eun-jeong;Do, Min-Hwan
    • 보존과학연구
    • /
    • s.30
    • /
    • pp.47-61
    • /
    • 2009
  • Cultural heritages are affected by various environmental factors. Main factors are temperature, humidity, light and indoor air pollutants such as ozone, nitrogen oxides. Especially humidity condition is very important. Low humidity condition can cause contraction and high humidity condition can lead to growth of microorganism. This study is conducted to appraise an applicability of the Humidity Indicator which is one of the simple method for humidity control. The Humidity Indicator shows the humidity conditions through color change. Therefore, photometer was used to correctly measure the color change of Humidity Indicator. As a result of lab test, Humidity Indicators was stabilized after one hour from en exposure in a certain humidity condition and the indicators indicated clear correlations between color changes of Humidity Indicators and humidity conditions. Some Humidity Indicators which had been selected through the lab tests were applied to preservation facilities of cultural heritages and the indicators indicated closed correlations with humidity conditions in indoor of facilities.

  • PDF

A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process (연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구)

  • 이주상;김신도;김광영;김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF