• Title/Summary/Keyword: oxygenation

Search Result 405, Processing Time 0.024 seconds

Eutrophication and Seasonal Variation of Water Quality in Masan-Jinhae Bay (마산-진해만의 수질 부영양화 및 계절 변동)

  • Cho, Kyung-Je;Choi, Man-Young;Kwak, Seung-Kook;Im, Sung-Ho;Kim, Dae-Yun;Park, Jong-Gyu;Kim, Young-Eui
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.193-202
    • /
    • 1998
  • Water quality of Masan-Jinhae Bay was monitored from January 1996 to August 1997. The monitoring focused on the spatial and vertical gradients and seasonal changes of eutrophication parameters such as nutrients, DO and water transparency. Flagellate phytoplanktons persistently bloomed from April to October with monospecific or mixed algal blooms and dynamic algal successions were observed in this area. Algal blooms were highly correlated with salinity drops and made the water less transparent. Stratification of oxygen content was persistent through summer and oligo-oxygenation was developed in the bottom waters. Nutrient gradients were consistently maintained through the depth in summer and through spatial distribution from inner Masan Bay to outer Jinhae Bay in winter. Except the rainfall seasons, water quality was under the influence of the waste waters discharged from watershed around the Masan Bay. The waste waters would act as the primary factor for the water quality deterioration of the bay. Literature data for eutrophication were gathered and analyzed to review the water quality trends of the Masan and Jinhae bays since 1970. Annual mean COD and phosphate concentration consistently increased from 1975 to 1990 and decreased or dropped after 1991. The sediment of inner part of Masan Bay was dredged from 1991 to 1994 as a decontamination process and it is assumed that the dredging has weakened more or less the deterioration trend of the water quality of the bay.

  • PDF

Aggressive Surgical Treatment for Complex Cardiac Anomalies Associated with Right Atrial Isomerism (우심방 이성체를 동반한 복잡 심기형에 대한 적극적인 수술적 치료)

  • Hwang, Ui-Dong;Jung, Sung-Ho;Jhang, Won-Kyoung;Kim, Young-Hwue;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.569-573
    • /
    • 2007
  • A 3 month old female baby, who had been diagnosed with right atrial isomerism associated with total anomalous pulmonary venous return (TAPVR), a functional single ventricle and major aortopulmonary collateral arteries (MAPCA), underwent left MAPCA unifocalization and left Blalock-Taussig shunt (3.5 mm) at 3 months of age. The post-operative course was complicated by pulmonary venous congestion, and the drainage site of the TAPVR was found to be stenotic on echocardiography. We performed sutureless repair of the TAPVR along with unifocalization of the right MAPCA. She was put on an extracorporeal membrane oxygenator for 8 days after the 2nd operation, and she was able to come off the oxygenator with the placement of a central shunt (3 mm). She developed tracheal stenosis, which was presumably due to longstanding endotracheal intubation, and she then underwent tracheostomy. She was discharged to home on day 104 after the 1st operation, and she has been followed up for 2 months in a good clinical condition.

Failure of Mitral Valve Repair in a Dog with Severe Mitral Regurgitation (심한 이첨판 역류를 가진 개에 실시한 이첨판 성형술의 실패 원인)

  • Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.416-421
    • /
    • 2012
  • A 10-year-old 4-kg spayed female Chihuahua with severe congestive heart failure was referred for surgical treatment. Through several examinations, the dog was diagnosed as severe mitral regurgitation (MR) and moderate TR. Because of the poor prognosis associated with continuation of medical management, surgical repair of the mitral valve was considered as the treatment option for the dog. The mitral valve repair was performed undergoing cardio pulmonary bypass (CPB) circuit. However after mitral repair, the dog was died without recovery from anesthesia. Many risk factors associated with failure of cardiac surgery are included CPB management, hypothermia, organ dysfunction, hemorrhage, hypotension, electrolyte & acid base imbalance, and infection. Although the dog is died from the operation, it is an important to reveal the factors of failure in veterinary clinic. From the case report, causes of failure of mitral valve repair can be considered from the failure of oxygenation and gas exchange by hypothermia and serious hypotension with low heart rate by low cardiac output syndrome (LCOS). Through the several considerations from this case, it is known that coming cardiac surgery for mitral valve repair is required to be more careful for successful operation. Further it can be brought to increase success rate in further operation.

Nafamostat Mesilate Inhibits TNF-${\alpha}$-Induced Vascular Endothelial Cell Dysfunction by Inhibiting Reactive Oxygen Species Production

  • Kang, Min-Woong;Song, Hee-Jung;Kang, Shin Kwang;Kim, Yonghwan;Jung, Saet-Byel;Jee, Sungju;Moon, Jae Young;Suh, Kwang-Sun;Lee, Sang Do;Jeon, Byeong Hwa;Kim, Cuk-Seong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.3
    • /
    • pp.229-234
    • /
    • 2015
  • Nafamostat mesilate (NM) is a serine protease inhibitor with anticoagulant and anti-inflammatory effects. NM has been used in Asia for anticoagulation during extracorporeal circulation in patients undergoing continuous renal replacement therapy and extra corporeal membrane oxygenation. Oxidative stress is an independent risk factor for atherosclerotic vascular disease and is associated with vascular endothelial function. We investigated whether NM could inhibit endothelial dysfunction induced by tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$ ). Human umbilical vein endothelial cells (HUVECs) were treated with TNF-${\alpha}$ for 24 h. The effects of NM on monocyte adhesion, vascular cell adhesion molecule-1 (VCAM-1) and intracellular adhesion molecule-1 (ICAM-1) protein expression, p38 mitogenactivated protein kinase (MAPK) activation, and intracellular superoxide production were then examined. NM ($0.01{\sim}100{\mu}g/mL$) did not affect HUVEC viability; however, it inhibited the increases in reactive oxygen species (ROS) production and p66shc expression elicited by TNF-${\alpha}$ (3 ng/mL), and it dose dependently prevented the TNF-${\alpha}$ -induced upregulation of endothelial VCAM-1 and ICAM-1. In addition, it mitigated TNF-${\alpha}$ -induced p38 MAPK phosphorylation and the adhesion of U937 monocytes. These data suggest that NM mitigates TNF-${\alpha}$ -induced monocyte adhesion and the expression of endothelial cell adhesion molecules, and that the anti-adhesive effect of NM is mediated through the inhibition of p66shc, ROS production, and p38 MAPK activation.

Low Frequency Fluctuation Component Analysis in Active Stimulation fMRI Paradigm (활성자극 파라다임 fMRI에서 저주파요동 성분분석)

  • Na, Sung-Min;Park, Hyun-Jung;Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.115-120
    • /
    • 2010
  • Purpose : To separate and evaluate the low frequency spontaneous fluctuation BOLD signals from the functional magnetic resonance imaging data using sensorimotor active task. Materials and Methods : Twenty female archery players and twenty three control subjects were included in this study. Finger-tapping task consisted of three cycles of right finger tapping, with a subsequent 30 second rest. Blood oxygenation level-dependent (BOLD) data were collected using $T2^*$-weighted echo planar imaging at a 3.0 T scanner. A 3-D FSPGR T1-weighted images were used for structural reference. Image processing and statistical analyses were performed using SPM5 for active finger-tapping task and GIFT program was used for statistical analyses of low frequency spontaneous fluctuation BOLD signal. Results : Both groups showed the activation in the left primary motor cortex and supplemental motor area and in the right cerebellum for right finger-tapping task. ICA analysis using GIFT revealed independent components corresponding to contralateral and ipsilateral sensorimotor network and cognitive-related neural network. Conclusion : The current study demonstrated that the low frequency spontaneous fluctuation BOLD signals can be separated from the fMRI data using finger tapping paradigm. Also, it was found that these independent components correspond to spontaneous and coherent neural activity in the primary sensorimotor network and in the motor-cognitive network.

A New Shock Index for Predicting Survival of Rats with Hemorrhagic Shock Using Perfusion and Lactate Concentration Ratio (흰쥐의 출혈성 쇼크에서 관류와 젖산 농도 비를 이용한 새로운 생존 예측 지표 개발)

  • Choi, Jae-Lim;Nam, Ki-Chang;Kwon, Min-Kyung;Jang, Kyung-Hwan;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.1-9
    • /
    • 2011
  • Hemorrhagic shock is a clinically widespread syndrome characterized by inadequate oxygenation and supply. It is important to diagnose hemorrhagic shock in its early stage for improving treatment effects and survival rate. However, an accurate diagnosis and treatment could be delayed in the early stage of hemorrhagic shock by evaluating only vital signs such as heart rate and blood pressure. There have been many studies for the early diagnosis of hemorrhagic shock, reporting that lactate concentration and perfusion were useful variables for tissue hypoxia and metabolic acidosis. In this study, we measured both perfusion using a laser Doppler flowmeter and lactate concentration from the volume controlled hemorrhagic shock using rats. We also proposed a new shock index which was calculated by dividing lactate concentration by perfusion for early diagnosis. As a result of the survival prediction by the proposed index with the receiver operating characteristic curve method, the sensitivity, specificity, and accuracy of survival were 90.0, 96.7 and 94.0%, respectively. The proposed index showed the fastest significant difference among the other parameters such as blood pressure and heart rate. It could offer early diagnosis and effective treatment for human hemorrhagic shock if it is applicable to humans.

Short-term Mechanical Circulatory Support with a Centrifugal Pump - Results of Peripheral Extracorporeal Membrane Oxygenator According to Clinical Situation

  • Lee, Woo-Surng;Chee, Hyun-Keun;Song, Meong-Gun;Kim, Yo-Han;Shin, Je-Kyoun;Kim, Jun-Seok;Lee, Song-Am;Hwang, Jae-Joon
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Background: A peripheral extracorporeal membrane oxygenator (p-ECMO) has been developed to support patients who are dying due to a serious cardiopulmonary condition. This analysis was planned to define the clinical situation in which the patient benefits most from a p-ECMO. Material and Methods: Between June 2007 and Aug 2009, a total of 41 adult patients used the p-ECMO. There were 23 males and 18 females (mean age $54.4{\pm}15.1$ years). All patients had very unstable vital signs with hypoxia and complex cardiac problems. We divided the patients into 4 groups. In the first group, a p-ECMO was used as a bridge to cardiac operation. In the second group, patients did not have the opportunity to undergo any cardiac procedures; nevertheless, they were treated with a p-ECMO. In the third group, patients mostly had difficulty in weaning from CPB (cardiopulmonary bypass) after cardiac operation. The fourth group suffered from many complications, such as pneumonia, bleeding, infections, and LV dysfunction with underlying cardiac problems. All cannulations were performed by the Seldinger technique or cutting down the femoral vessel. A long venous cannula of $DLP^{(R)}$ (Medtronic Inc, Minneapolis, MN) or $RMI^{(R)}$ (Edwards Lifesciences LLC, Irvine, CA) was used together with a 17~21 Fr arterial cannula and a 21 Fr venous cannula. As a bypass pump, a Capiox emergency bypass system ($EBS^{(R)}$; Terumo, Tokyo, Japan) was used. We attempted to maintain a flow rate of $2.4{\sim}3.0\;L/min/m^2$ and an activated clotting time (ACT) of around 180 seconds. Results: Nine patients survived by the use of the p-ECMO. Ten patients were weaned from a p-ECMO but they did not survive, and the remainder had no chance to be weaned from the p-ECMO. The best clinical situation to apply the p-ECMO was to use it as a bridge to cardiac operation and for weaning from CPB after cardiac operation. Conclusion: Various clinical results were derived by p-ECMO according to the clinical situation. For the best results, early adoption of the p-ECMO for anatomical correction appears important.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Effect of Blood Donation on the Donor's Hemorheological Properties (헌혈이 헌혈자의 혈유변학적 지표에 미치는 영향)

  • Lee, Byoung Kwon
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.229-239
    • /
    • 2018
  • The circulatory system is closely related to the inter-relationship between the anatomy of the heart and blood vessels, and the fluid dynamic properties of blood. The physical properties of blood, which affect blood flow, are called hemorheologic factors. Hemorheologic factors, such as blood viscosity and erythrocyte aggregation, are influenced mainly by hematocrit. A higher hematocrit level results in an increase in blood viscosity, erythrocyte aggregation, which impedes the circulation itself, and tissue oxygenation. An excess of serum ferritin causes injury to vascular endothelial cells and erythrocytes via oxygen free radicals. In addition, an excess of blood can aggravatee the adverse effects of the hemorheologic parameters and induce atherogenesis, microcirculatory disturbances, and major cardiovascular events. A preventive and therapeutic approach with a phlebotomy or blood donation has been stimulated by the knowledge that blood loss, such as regular donations, is associated with significant decreases in key hemorheologic variables, including blood viscosity, erythrocyte aggregation, hematocrit, and fibrinogen. Major cardiovascular events have been improved in regular blood donors by improving blood flow and microcirculation by decreasing the level of oxidative stress, improving the hemorheologic parameters, and reducing the serum ferritin level. Confirmation of the positive preventive and therapeutic effects of blood donations on cardiovascular disease by a well-designed and well-controlled Cohort study may be good news to patients with cardiovascular disease or at risk of these diseases, as well as patients who require a transfusion.

Field Applications of Non-powered Downward Water Circulation System to Improve Reservoir Water Quality (저수지 수질개선을 위한 무동력 하향류 수류순환시스템의 현장적용성)

  • Jang, YeoJu;Lim, HyunMan;Jung, JinHong;Park, JaeRho;Kim, WeonJae
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.109-119
    • /
    • 2019
  • Eutrophication has occurred due to the inflow of various water pollutants in many Korean reservoirs with low depth, and algal blooms of surface layer and low oxygenation of deep layer have repeated every year. There are several existing technologies to alleviate the stratification of reservoirs, but it is difficult to apply them in field sites due to the necessity of electric power and low economic efficiency. In this study, a non-powered water circulation system using natural energy of wind and water flow has been developed, and two test-beds constructed in the reservoirs with different conditions and examined its field applicability. Through computational fluid dynamics (CFD) simulation, it has been shown that the water circulation system could induce the downward flow to mitigate the stratification between surface and deep layers, and its influence radius could reach about 30 m. As a result of long-term monitoring of the test-beds, various water quality improvement effects have been observed such as moderation of DO fluctuation by water circulation, reduction of DO supersaturation and prevention of excessive pH rising. In order to improve the applicability of the water circulation system, it is considered necessary to review countermeasures against flood and depth conditions of each reservoir.