• 제목/요약/키워드: oxygen sensor

검색결과 309건 처리시간 0.031초

Influence of Inductively Coupled Oxygen Plasma on the Surface of Poly(ether sulfone)

  • Lee, Do Kyung;Sohn, Young-Soo
    • 센서학회지
    • /
    • 제31권4호
    • /
    • pp.214-217
    • /
    • 2022
  • The effect of inductively coupled plasma (ICP) treatment with O2 gas on the surface properties of poly(ether sulfone) (PES) was investigated. X-ray photoelectron spectroscopy (XPS) was used to analyze the chemical characteristics of the O2 plasma-treated PES films. The surface roughness of the pristine and O2 plasma-treated PES films for different RF powers of the ICP was determined using an atomic force microscope (AFM). The contact angles of the PES films were also measured, using which the surface free energies were calculated. The O1s XPS spectra of the PES films revealed that the number of polar functional groups increased following the O2 plasma treatment. The AFM analysis showed the average surface roughness increased from 1.01 to 4.48 nm as the RF power of the ICP was increased. The contact angle measurements revealed that the PES films became more hydrophilic as the RF power of the ICP was increased. The total surface energy increased with the RF power of the ICP, resulting from the increased polar energy component.

심층신경망을 이용한 스마트 양식장용 사료 공급 시점 감지 시스템 구현 (An Implementation of Feeding Time Detection System for Smart Fish Farm Using Deep Neural Network)

  • 전주현;이윤호;주문갑
    • 대한임베디드공학회논문지
    • /
    • 제18권1호
    • /
    • pp.19-24
    • /
    • 2023
  • In traditional fish farming way, the workers have to observe all of the pools every time and every day to feed at the right timing. This method causes tremendous stress on workers and wastes time. To solve this problem, we implemented an automatic detection system for feeding time using deep neural network. The detection system consists of two steps: classification of the presence or absence of feed and checking DO (Dissolved Oxygen) of the pool. For the classification, the pretrained ResNet18 model and transfer learning with custom dataset are used. DO is obtained from the DO sensor in the pool through HTTP in real time. For better accuracy, the next step, checking DO proceeds when the result of the classification is absence of feed several times in a row. DO is checked if it is higher than a DO reference value that is set by the workers. These actions are performed automatically in the UI programs developed with LabVIEW.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

ZigBee와 CAN 통신을 이용한 자동차 배기가스 검출 및 자기진단 시스템 (Car Exhaust Gas Detection and Self-Diagnosis System using ZigBee and CAN Communications)

  • 천종훈;김국세;박종안
    • 한국ITS학회 논문지
    • /
    • 제7권6호
    • /
    • pp.48-56
    • /
    • 2008
  • 본 논문은 대기오염의 주범인 자동차 배기 가스량을 체크하고 차량내의 고장 유 무 진단 시스템 개발이다. 시스템 엔진 정보 추출을 위해 차량 CAN 통신을 이용하고 정보 전송을 위해 ZigBee를 통해 데이터 전송을 한다. 차량 CAN을 위해 차량에서 자체 제공되는 OBD-II 프로토콜을 사용하여 차량의 각종 센서 정보 및 O2 센서 값을 통해 차량 상태 정보 및 배기 가스양을 계산한다. 주행 중인 자동차 엔진 및 내부 고장에 잘 알지 못하는 일반 사용자를 위해 운행 중 실시간 차량의 자가진단 시스템 구축을 목적으로 하고 고장진단 프로토콜 전송을 위한 무선통신 인터페이스로 저 전력 저비용 ZigBee 통신 인터페이스를 구축한다. 자동차 그리고 진단 시스템의 통신을 위해 ZigBee 시스템을 통하여 효율적 저비용 통신 인터페이스를 구성하여 차량내의 엔진 및 각종 센서 정보 네트워크를 지원한다. 차량에서 전송되어 온 각종 센서정보는 ZigBee 기반을 통해 ZigBee 메인 컨트를 시스템에 전송된다. 차량에 이상이 생겼을 때 트러블 코드를 저장하고 자동차가 정비소에 갔을 때 정확한 판단을 하여 신속하게 처리 할 수 있게 해 주며 자동차에 대해서 잘 알지 못하는 운전자에게 정확한 정보를 제공한다. 또한 멀티미디어 시스템 기능을 추가하고 주행 중 무선 인터넷이 가능하도록 시스템을 확장한다. 마지막으로 주행 중 차량 자가진단을 위해 저 전력 임베디드 리눅스 시스템을 구축하고 실 실험을 통하여 구현하고 검증한다.

  • PDF

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

동일면상에 heater와 감지전극을 형성한 마이크로가스센서의 제작 및 특성 (Characteristics and Fabrication of Micro-Gas Sensors with Heater and Sensing Electrode on the Same Plane)

  • 임준우;이상문;강봉휘;정완영;이덕동
    • 센서학회지
    • /
    • 제8권2호
    • /
    • pp.115-123
    • /
    • 1999
  • PSG(800nm)/$Si_3N_4$ (150nm)로 구성된 유전체 membrane 윗면에 heater와 감지전극을 등일면상에 동시에 형성하였다. 제작된 소자의 전체 면적은 $3.78{\times}3.78mm^2$이고, diaphragm의 면적은 $1.5{\times}1.5mm^2$이며, 감지막치 면적은 $0.24{\times}0.24mm^2$였다. 그리고 diaphragm내의 열분포 분석을 유한요소법을 이용하여 수행하였으며, 실제로 제작된 소자의 열분포와 비교하였다. 소비전력은 동작온도 $350^{\circ}C$에서 약 85mW였다. Sn 금속막을 상온과 $232^{\circ}C$의 두 가지 기판온도에서 열증착하였고, 이를 $650^{\circ}C$의 산소분위기에서 3시간 열산화함으로써 $SnO_2$ 감지막을 형성하였다. 그리고 이를 SEM과 XRD로 특성을 분석하였다. 제작된 소자에 대해서 온도 및 습도에 대한 감지막의 영향 및 부탄가스에 대한 반응특성도 조사하였다.

  • PDF

전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서 (Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F)

  • 지성은;이상혁;이혜진
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.258-263
    • /
    • 2023
  • 본 연구에서는 일회용 센서 칩으로 제작 가능한 스크린 프린팅된 탄소칩 전극(screen printed carbon electrode; SPCE) 표면에 전도성고분자 및 효소 티로시나아제(tyrosinase, Tyr)를 적층하여 전기화학적인 방법으로 남성 질환, 갑상선 질환 등과 연관성이 입증된 내분비계 교란 물질인 비스페놀F (bisphenol F, BPF) 검출에 적용하였다. 산소 플라즈마 처리를 통해 음전하를 띠게 한 SPCE 작업전극 표면에 양전하를 띄는 전도성 고분자인 poly(diallyldimethyl ammonium chloride) (PDDA)과 음전하를 띠는 고분자 화합물 poly(sodium 4-styrenesulfonate) (PSS) 그리고 PDDA 순서대로 정전기적인 인력으로 층을 쌓고, 최종적으로 pH (7.0)를 조절하여 음전하를 띄게 한 효소, Tyr층을 올려 PDDA-PSS-PDDA-Tyr 센서를 제작하였다. 상기 전극 센서를 기질이자 타겟분석물인 BPF 용액에 접촉하면, 전극 표면에서 Tyr 효소와 산화반응에 의해 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione)가 생성되고, 순환전압전류법과 시차펄스전압전류법을 이용하여 생성물을 0.1 V (vs. Ag/AgCl)에서 환원하면 4,4'-methylenebis(benzene-1,2-diol)이 생성되면서 발생하는 피크 전류 값의 변화를 측정함으로써, BPF의 농도를 정량적으로 분석하였다. 또한, 기존에 많은 연구에서 사용되는 인산완충생리식염수를 대체할 수 있는 이온성 액체 전해질을 사용하여 BPF의 검출 성능 결과를 비교하였다. 또한 BPF와 유사한 구조를 갖는 방해물질로 작용하는 비스페놀S에 대한 선택성을 확인하였다. 마지막으로 실험실에서 준비한 실제 시료안의 BPF의 농도를 분석하는데 제작한 센서를 적용함으로써 센서의 실제 적용 가능성을 입증하고자 하였다.

해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정 (Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer)

  • 이재성;김기현;유준;이필용;정래홍;이원찬;한정희;이용화
    • 한국해양학회지:바다
    • /
    • 제9권2호
    • /
    • pp.64-72
    • /
    • 2004
  • 유기물이 많이 유입되는 해상어류가두리 양식장 퇴적물에서 전극 크기가 25$mu extrm{m}$인 미세전극을 이용하여 공극수의 산소, 황화수소, pH의 미세연직 농도를 측정하였다. 산소와 황화수소의 연직분포에서 얻어진 미세구간에 1차 확산ㆍ반응모델을 적용하여 각 구간에서의 산소 소모율, 황화수소 산화율, 황산염의 환원율을 추정하였다. 산소투과깊이는 0.75 mm였으며, 미세구간은 상부와 하부층 2개로 나누어졌다. 산소소모는 황화수소의 산화 영향으로 상부층에 비해 하부층에서 높았고 총산소소모플럭스는 0.092 $\mu$mol $O_2$$cm^{-2}$ $hr^{-1}$였다. 산화층에서 황화수소 산화는 0.7 mm 두께에서 0.030$\mu$mo1 H$_2$S $cm^{-2}$ $hr^{-1}$의 결과를 나타냈으며, 이 곳에서 황화수소의 turnover time은 약 2분으로 화학적 산화와 생물학적 산화가 동시에 일어나고 있었다. 황화수소와 산소의 소모율 비는 0.84로 황화수소 산화에 산소 이외의 다른 전자수용체가 사용되거나 산소-황화수소 경계면 주변에서 황 침전의 가능성을 시사하고 있었다. 추정된 총 황산염 환원 플럭스는 0.029$\mu$mol $cm^{-2}$ $hr^{-1}$로서 총산소소모플럭스의 60% 이상을 차지하고 있어 무산소 환경에서 유기물 분해가 산화환경에서보다 큰 역할을 하는 것으로 나타났다.

격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석 (Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.118-128
    • /
    • 1996
  • 0$\leq$y$\leq$0.33 범위의 조성을 가진 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 격자상수를 least-squares method에 의해 구하였다. 고용체의 격자상수는 Er의 첨가량이 증가함에 따라 다음과 같이 직선적으로 감소하였다 : a($\AA$)=5.4695-0.220y, (0$\leq$y$\leq$0.33). $U_{1-y}Er_{y}O_2$고용체에서 Er 함량에 대한 격자상수의 변화계수, y=-0.220은 $Er^{3+}$ 의 첨가에 따른 전기적 중성을 만족하기 위해 고용체내에서 $U^{5+}$ 또는 $U^{6+}$ 이온이 각각 존재한다고 가정하여 계산된 값, y =-0.273, -0.156의 사이에 있다. $U_{1-y}Er_{y}O_2$ 고용체와 $UO_{2+x}$ 의 산소포텐샬을 산소분압 $10^{-14}$ -$10^{-3}$, 온도 1200~$1500^{\circ}C$에서 thermogravimetric method에 의해 측정하였다. $CO_2$/CO 혼합가스로써 TGA내의 산소분압을 조절하였으며, 고온산소센서를 사용하여 $Po_2$ 값을 측정하였다. (equation omitted) 값은 1200~$1500^{\circ}C$ 범위에서 y=0.06인 고용체의 경우 -360부터 -270H1mo1e, 그리고 y=0.20인 고용체에서는 -320부터 -220kJ/mo1e까지 각각 급격하게 변하는 것으로 나타났다. $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체에서 Er의 함량이 낮은 경우에는 $U^{5+}$ $U^{4+}$ model이 산소포텐샬 데이타에 접근하는 것으로 나타났으나, y=0.06 이 상인 경우에는 평균 우라늄 원자가모델에 의해서 산소 포텐샬의 변화를 설명할 수 없었다.

  • PDF

가스센서용 $SnO_2$분말 제조시 잔류 염소이온이 Sn수화물의 열분해거동 및 분말물성에 미치는 영향 (Effect of Residual Chloride Ion on Thermal Decomposition Behaviour os Stannic Acid and Physical Properties of $SnO_2$ Powder Fabricated for Gas Sensor)

  • 송국현;최병우;박재환;박순자
    • 한국재료학회지
    • /
    • 제4권8호
    • /
    • pp.934-944
    • /
    • 1994
  • 수산화물법에 의해 제작된 $\alpha$-stannic acid의 열분해 거동과 $SnO_{2}$분말의 성질에 미치는 잔류염소이온의 영향을 관찰하였다. $SnCl_{4}$$NH_{4}$OH 수용액을 중화시켜 $\alpha$-stannic acid침전물을 제작하고 $NH_{4}NO_{3}$수용액으로 세척하였다. 분말내의 잔류 염소이온의 양을 주절하기 위하여 세척정도를 3단계로 조정하였다. 세척후 $100^{\circ}C$에서 건조하고, $500^{\circ}C$ ~ $1100^{\circ}C$에서 하소함으로써 $SnO_{2}$분말을 제조하였다. $\alpha$-stannic acid의열분해 거동ㅇ르 DT-TGA 와 FTIR을 통하여 관찰하고, $SnO_{2}$분말의 조성과 입자크기 및 비표면적을 각각 AES, TEM 및 BET을 통하여 측정하였다. 잔류 염소이온 양이 감소되면, 저온 하소시 일차입자의 상대적 크기가 커지는 반면 고온하소시에는 상대적으로 감소되었ㄷ. 잔류 염소이온의 일부는 $\alpha$-stannic acid내의 격자산소 자리에 위치함으로써, 저온가열시 결정수탈리와 결정화를 지연시키고 또한 고온가열시에는 이의 증발에 의해 산소공공이 생성되어 소결을 촉진시킨다고 제의하였다.

  • PDF