Oxygen Index of Fire-Retardant-Treated Plywood in Burning Test (산소지수법(酸素指數法)에 의한 내화처리합판(耐火處理合板)의 연소시험(燃燒試驗))

  • Lee, Phil Woo;Eom, Young Geun;Kim, Hyun Joong
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.4
    • /
    • pp.419-424
    • /
    • 1989
  • To obtain relative effectiveness in fire resistance among fire retardant chemicals, oxygen indices were determined for 3.5 mm thick, three-ply, meranti plywoods, treated with 5 commercial chemicals and water and then press-dried, through Up and Down method following oxygen index test of ASTM D 2863-77. The oxygen indices obtained were 28.4 for ammonium sulfate, 26.9 for monoammonium phosphate, 43.4 for diammonium phosphate, 30.1 for borax-boric acid, 32.4 for minalith, and 25.5 for water. Therefore, diammonium phosphate was found to rank first in fire-retardant effectiveness, followed by minalith, borax-boric acid, ammonium sulfate, and monoammonium phosphate in turn, judging from the fact that highly flammable materials are likely to have a low oxygen index.

  • PDF

A Study on Cerebral Blood Flow Enhancement Device Using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치에 관한 연구)

  • Lim, Jung-Hyun;Joh, In-Hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.188-192
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. However, invasive methods, such as surgery, may result in postoperative complications or side effects. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm was measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm by 75% of the moment when it falls to the leg and the pressure calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

  • PDF

EVALUATION OF WATER REPELLENCY FOR SILICON OXIDE FILMS PREPARED BY RF PLASMA-ENTRANCED CVD

  • Sekoguchi, Hiroki;Hozumi, Atsuhi;Kakionoki, Nobuyuki;Takai, Osamu
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.781-787
    • /
    • 1996
  • Silicom oxide films with good water repellency were prepared by rf plasma-enhanced CVD (rf-PECVD) using four kinds of organosilicon compound, which had different number of methyl ($CH_3$) groups, and oxygen as gas sources. The differences in the deposition rates, film composition and film properties were studied in detail. Water repellency depended on the number of $CH_3$ groups in the organosilicon compounds and the partial pressure of oxygen in the plasma. The highest contact angle for water drops, about 95 degrees, was obtained when trimethy lmethoxy silane (TMMOS) was used. The contact angle decreased with the amount of oxygen gas introduced into the plasma. The dissociation of $CH_3$ groups by adding oxygen was comfirmed by Fourier transform infrared spectroscopy(FTIR) and X-ray photoelectron spectroscopy (XPS). The optical properties were estimated by double-beam spectroscopy and ellipsometry. The transmittance of the glass plate coated by the film prepared with tetramethoxy silane (TMOS) was about 90% and the refractive index of film was 1.44. This value was smaller than the refractive index of a glass plate(soda lime glass, refractive index is 1.515) and this film played a role of anti-refractive coating.

  • PDF

A Study on the Oxygen Saturation Level Changes in the Blood Exposed to the Static Magnetic Field (자속에 노출된 인체의 혈중 산소 포화농도의 변화에 관한 연구)

  • Jung, Yong-Chul;Lee, Dong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.87-90
    • /
    • 2007
  • The effects of static magnetic field on the human biological system are becoming increasingly more important with the adaption of static magnet in the medical community. It is the goal of this paper to review the effects of static magnetic fields on oxygen saturation level in blood. The results of this paper show that the oxygen saturation level increased in the blood in index finger when the static magnetic dipole was fitted on index finger.

Supplementation of cryoprotective extender with resveratrol decreases apoptosis index and reactive oxygen species levels in post-thaw dog sperm

  • Bang, Seonggyu;Tanga, Bereket Molla;Qamar, Ahmad Yar;Fang, Xun;Seong, Gyeonghwan;Nabeel, Abdelbagi Hamad Talha;Yu, Iljeoung;Cho, Jongki
    • Korean Journal of Veterinary Research
    • /
    • v.61 no.4
    • /
    • pp.29.1-29.7
    • /
    • 2021
  • Resveratrol (RSV, 3,5,4'-trihydroxytrans-stilbene) protects sperm from cryo-induced damage in various animal and human species. In this study, we aimed to assess the effect of dog sperm cryoprotective extender containing RSV on the quality of post-thaw dog sperm. Sperm were collected from 4 Beagles and supplemented with different concentrations of RSV (0, 100, 200, and 400 µM). After thawing, apoptosis index, and reactive oxygen species (ROS) levels were assessed to determine post-thaw sperm quality. Dog sperm cryopreserved with 400 µM RSV showed significant improvement in post-thaw sperm quality with lower apoptosis index and ROS levels (p < 0.05). Our results showed that the supplementation of dog sperm cryoprotective extender with RSV at a concentration of 400 µM improved the post-thaw dog sperm quality in the term of sperm ROS production and apoptosis. In addition, we emphasize the necessity of testing the ROS levels and apoptosis index using flow cytometry to determine the quality of post-thaw semen.

On a Reading Aloud to Relieve the Decrease in Blood Oxygen Saturation when Jogging

  • Tian, Zhixing;Bae, MyungJin
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.95-100
    • /
    • 2020
  • Recently, the problem of hypoxia caused by jogging is attracting attention. To solve this problem, this paper proposed a new solution. This paper proved that as a vocalization method of reading aloud, it is possible to increase air intake and activate lung function to exchange more air and obtain more oxygen. Then, blood oxygen saturation was used as an evaluation index for the body's oxygen content level to prove its effectiveness. A photoelectric pulse oximeter developed on the basis of different light absorption principles in blood was used to test blood oxygen saturation. Experimental results show that a certain degree of hypoxia is induced when a lot of oxygen is required due to jogging. Therefore, it was proved that the new vocal breathing method by reading books can increase the blood oxygen saturation of the body and improve the hypoxia of the body. Reading vocal breathing is a simple and efficient oxygen saturation recovery breathing method.

Application of Clinical Features and the Degree of Oxygen Desaturation as a Screening Test for the Obstructive Sleep Apnea Syndrome (수면무호흡증후군의 선별검사로서 임상양상과 산소포화도 이용)

  • Ko, Jae-Kwang;Kim, Leen;Suh, Kwang-Yoon;Shin, Dong-Kyun
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.1
    • /
    • pp.60-67
    • /
    • 1994
  • Objectives: The Obstructive sleep apnea syndrome is characterized by snoring, observed apnea during sleep and excessive daytime sleepiness. The overnight polysomnographic recording is used to investigate patients with possible obstructive sleep apnea syndrome. But the overnight polysomnographic recording is time consuming, expensive, and labor-intensive. Recently in diagnosis of obstructive sleep apnea syndrome, several simple screening tests have been suggested. Methods: This study was performed to assess the probability of application of clinical features and the degree of oxygen desaturation as a screening test for the obstructive sleep apnea syndrome. The sensitivity and specificity of the self-report of clinical features including snoring, observed apnea during sleep, excessive daytime sleepiness and insomnia were tested. And the degree of oxygen desaturation measured by oximetry in 42 subjects were compared with the overnight polysomnographic recording results. Results: In the prediction of apnea index more than 5, the sensitivity of observed apnea during sleep, snoring, excessive daytime sleepiness and insomnia were 96.8%, 93.5%, 38.7%, 25.8% and the specificity of those clinical features were 182%, 36.4%, 100%, 72.7%, respectively. In the prediction of apnea index more than 5, the sensitivity and specificity of the combination of more than three self-report clinical features were 54.8% and 90.9%. The degree of oxygen de saturation and maximal apnea duration in the group of apnea index more than 5 were significantly different from those in the group of apnea index below 5(P<0.001). And the apnea index was significantly correlated with the degree of oxygen desaturation and maximal apnea duration(P<0.001). Conclusion: These results suggest that application of clinical features alone as a screening test for the obstructive sleep apnea syndrome is inadequate because of it's high rate of false positive and false negative results. The degree of oxygen desaturation measured by oximetry is possibly applicable to screening test and follow up evaluation of treatment efficacy for the obstructive sleep apnea syndrome.

  • PDF

A Study on Perpendicular Flame Retardant Characteristic Improvement of Halogen-free Flame Retardant Compounds by Nanoclay Addition (나노클레이 첨가에 따른 할로겐프리 난연컴파운드의 수직난연 특성 향상에 관한 연구)

  • Hwang, Chan-Yun;Yang, Jong-Seok;Seong, Baeg-Yong;Kim, Ji-Yeon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • The object of this study is to obtain the optimum mix proportion of halogen free compound with flame resistance and, for the purpose, thermal/electrical characteristics test are conducted using compatibilizing agents, flame resistance agents, hydroxide aluminum, sunscreen, antioxidant and silicon oil on the base resin of linear low density polyethylene (LLDPE), Ethylene vinyl acetate copolymer (EVA). Existing compound method accompanies many requirements to be satisfied including a lot of addition of flame resistance agents, prohibition of impact on mixing capability with base and property and etc. In this study, different from the existing method, the optimum mix proportion is determined and experimented by adding nano clay. Oxygen index test shows no difference between specimens while T-6, T-9 shows oxygen index of 29[%] and 26[%], respectively. This is concluded that hydroxide aluminum, which is a flame resistance agent, leads low oxygen index. From UL94-V vertical flame resistance test, the combustion behavior is determined as V-0, Fail based on UL94-V decision criteria. Viscometry shows low measurements in specimens with separate addition of compatibilizing agents or nano clay. Volume resistivity test shows low measurement mainly in specimens without compatibilizing agents. Therefore, with the flame resistance compound shows better performance for thermal/electrical property and the optimum mix proportion are achieved among many existing materials.

A Study on Combustion Characteristics in each Coating Thickness of Fire Retardant Paints (난연도료의 도포 두께별 연소특성에 관한 연구)

  • Kim, Hong;Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.36-41
    • /
    • 2003
  • This experimental study shows the combustion characteristics for each coating thickness of water and oil paint which are used as fire retardant paints that prevent fire propagation through cables in underground culverts and trays. To evaluate combustion characteristics, smoke density(ASTM E 662) and Limited Oxygen Index(ASTM D 2863) experiment method was used. As the results of this study, the combustion characteristics of fire retardant paints produced the following : (a) The molt suitable coating thickness of fire retardant paint was 1.5∼2.0 mm in water paint and 0.2 mm in oil paint. (b) Flaming method in experiments of smoke density were found to be higher than Non-flaming method. (c) Water paint has the fire retardant effect and characteristics better than oil paint in measurement results of smoke density and oxygen index. (d) The oxygen index of water and oil fire retardant was able to know that it was satisfied a standard (30 or above).

Cerebral blood flow enhancement device using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치)

  • Lim, Jung-hyun;Joh, In-Hee;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1083-1089
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm is measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm is calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.