• Title/Summary/Keyword: oxygen

Search Result 15,889, Processing Time 0.045 seconds

Combustion and Radiation Characteristics of Oxygen-Enhanced Inverse Diffusion Flame

  • Hwang, Sang-Soon;Gore, Jay-P
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1156-1165
    • /
    • 2002
  • The characteristics of combustion and radiation heat transfer of an oxygen-enhanced diffusion flame was experimentally analyzed. An infrared radiation heat flux gauge was used to measure the thermal radiation of various types of flames with fuel, air and pure oxygen. And the Laser Induced Incandescence (LII) technique was applied to characterize the soot concentrations which mainly contribute to the continuum radiation from flame. The results show that an oxygen-enhanced inverse diffusion flame is very effective in increasing the thermal radiation compared to normal oxygen diffusion flame. This seems to be caused by overlapped heat release rate of double flame sheets formed in inverse flame and generation of higher intermediate soot in fuel rich zone of oxygen-fuel interface, which is desirable to increase continuum radiation. And the oxygen/methane reaction at slight fuel rich condition (ø=2) in oxygen-enhanced inverse flame was found to be more effective to generate the soot with moderate oxygen availability.

The Effect of Oxygen Administration on Cerebrum Lateralization in Verbal Task (언어 과제 수행 시 산소 공급이 대뇌 편측화에 미치는 영향)

  • 정순철;김익현;김승철;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.81-83
    • /
    • 2003
  • The present study attempted to observe what changes the supply of highly concentrated(30%) oxygen cause to people's ability and cerebrum lateralization of verbal cognition, compared to air of normal oxygen concentration(21%). The experiment consisted of two runs, one for verbal cognition test with normal air(21% of oxygen) and for verbal cognition test with more oxygen in the air(30% of oxygen). Functional brain images were taken form 3T MRI using the single-shot EPI method. There were more activations observed at the occipital, parietal, temporal, and frontal lobes, but there were no changes in cerebrum lateralization with 30% oxygen administration. The result of task performance showed the accuracy increased at 30%'s concentration of oxygen rather than 21%'s. It is concluded that the positive effect on the verbal cognitive performance level by the highly concentrated oxygen administration was due to changeless increase of left and right cerebrum activation.

  • PDF

Release of Oxygen from a Nano-sized Water Droplet Observed using Molecular Dynamics

  • Lee, Chang-Han;Ambrosia, Matthew Stanley
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.927-935
    • /
    • 2016
  • Dissolved oxygen is necessary for many biological processes as well as many industrial practices. Dissolved oxygen released from water in dissolved air flotation (DAF) systems can be have many different applications. However, DAF systems are very costly to operate. To develop more efficient DAF systems, a deeper understanding of the process of oxygen being released from water is required. In this study, molecular dynamics (MD) simulations were used to simulate 100 oxygen molecules surrounded by 31002 water molecules at temperatures ranging from $0^{\circ}C$ to $100^{\circ}C$. Simulations were carried out for 10 ns, during which, in most cases, all the oxygen molecules were released from the water droplet. With MD simulations, visualization of the molecules escaping the water droplet was possible, which aided the understanding of the interactions between molecules at the nano-scale. The results showed that as the oxygen molecules moved near the edge of the water droplet that the oxygen molecules hesitated before escaping the water droplet or returned to the interior of the water droplet. This was because of the attractive forces between the water and oxygen molecules. Moreover, after most of the oxygen molecules were released from the droplet, some were found to return to the droplet's edge or even the interior of the droplet. It was also confirmed that oxygen molecules were released at a faster rate at higher temperatures.

Automatic Control of Fraction of Inspired Oxygen in Neonatal Oxygen Therapy using Fuzzy Logic Control

  • Chanyagorn, Pornchai;Kiratiwudhikul, Phattaradanai
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.107-116
    • /
    • 2016
  • Premature babies of less than 37 weeks gestation might require oxygen therapy as an integral part of treatment and respiratory support. Because of their under-developed lungs, these so-called "preemies" might contract respiratory distress syndrome (RDS). To treat RDS, neonatal oxygen therapy is administered, where controlled oxygen gas is measured as a fraction of inspired oxygen ($FiO_2$). However, exposure to high oxygen content during long treatment could cause oxygen intoxication, which might cause permanent blindness due to retinopathy of prematurity (ROP), whereas insufficient oxygen exposure could cause severe hypoxia. A doctor would use oxygen saturation ($SpO_2$) data and prescribe a dose of $FiO_2$ to maintain $SpO_2$ within a suitable range. One objective is to maintain $SpO_2$ within the acceptable range using $FiO_2$ that is as low as possible. Adjustment of $FiO_2$ would normally be done by nurses every 15 to 30 minutes, which might not be safe in many situations. An error in $FiO_2$ adjustment during a manual procedure could be as large as +/- 2.5%. This paper presents a system that can determine an $FiO_2$ value suitable to the current $SpO_2$ and that automatically adjusts $FiO_2$ with an error clearance of +/- 0.25%.

The Effect of Co-culture and Oxygen Concentration on In Virto Fertilization of Follicular Oocytes in Korean Native Cattle (공배양 및 산소농도가 한우 난포란의 체외발생에 미치는 영향)

  • 이재관;윤준진;황성수;윤종택;김창근;정영채
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.43-50
    • /
    • 1998
  • The effect of oxygen tension on embryonic development in co-culture was evaluated from the standpoint of the reduction of dissolved oxygen concentration by the oxygen consumption of feeder cells. Three co-culture systems using bovine oviductal epitherial cells (BOEC), African green monkey kidney cells (Vero cells) or buffalo rat liver cells (BRLC) have been compared in terms of development of bovine embryos derived from oocytes matured and fertilized in vitro. Among the co-cultured embryo, Vero cells su, pp.rted the highest developmental rate (29%) and the other two showed the similar rates. When the co-cultures were incubated in three different oxygen tension such as 5, 10, 20% oxygen atmosphere, embryos co-cultured with Vero cells at 10%-O2 resulted in the highest percentage of development. From the measurement of oxygen consumption of feeder cells, BRLC consumed 1.38 10-10 mg-O2/min/cell which was higher than 0.94 10-10 and 0.26 10-10mg-O2/min/cell for Vero cells and BOEC, respectively. Based on the oxygen consumption data, the phenomena of optimum oxygen tension required in embryo development in vitro has been analyzed, and we suggested that gas phase oxygen concentration, oxygen consumption rate of feeder cells and the number of feeder cells should be considered for the design of optimal co-culture system for effective fertilization of embryos in vitro.

  • PDF

Effect of Partial Oxygen Pressure on the Growth and Defense Enzyme Activities of Streptomyces coelicolor in continuous culture system (Streptomyces coelicolor의 연속 배양시 산소 분압에 따른 방어 효소의 활성 변화)

  • 박용두;이계준;노정혜
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.5
    • /
    • pp.538-543
    • /
    • 1994
  • Effect of partial oxygen pressure on the cell growth and the activities of oxidative defense enzymes were measured in the continuous culture of Streptomyces coelicolor. Both the wild type and the mutant strain resistant to hydrogen peroxide were cultured and the dry cell weight of the two cultures were measured at different oxygen tensions. Growth of the wild type was inhibited by oxygen at above 0.5 vvm. Growth of the hydrogen peroxide resistant mutant was stimulated by pure oxygen at 0.5 vvm but was inhibited by oxygen at 1.0 vvm. Therefore, growth of the hydrogen peroxide resistant mutant was less affected by the deleterious oxidative stress of oxygen. Activities of the several defense enzymes were also measured at different oxygen tensions. Activities of catalase and glucose-6-phosphate dehydrogenase increased significantly as oxygen pressure increased in the wild type culture. In the mutant, however, increase in those enzyme activities was not obvious whereas the uninduced levels of the above enzymes were higher than those of wild type. As judged by Western blotting, the amount of the major catalase increased as the oxygen pressure increased. This indicates that the induction of the catalase activity by oxygen pressure is mostly due to the increase in the expression level for the major catalase.

  • PDF

Combustion of PMMA in Liquid Oxygen Flow

  • Mitsutani, Toru;Ro, Takaaki;Yuasa, Saburo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.180-185
    • /
    • 2004
  • Our previous study showed that although the hybrid rocket engine with swirling gaseous oxygen had high performance, a direct injection of LOX with swirl into the combustion chamber of the hybrid rocket engine lowered the performance of the engine, compared to that with gaseous oxygen. In order to clarify this reason, combustion tests of a small PMMA combustor with an inner port diameter of 2 mm were conducted in liquid oxygen flow by comparison with gaseous oxygen flow. Although the oxygen mass fluxes of LOX were about two orders of magnitude larger than those of gaseous oxygen, the fuel regression rate of LOX were remarkably smaller than those of gaseous oxygen. For both liquid and gaseous oxygen, diffusion flames in the port of the grain controlled the combustion process of PMMA in oxygen flow. These results may be explained by the fact that only small amount of LOX vaporized and consumed in the combustion with PMMA while flowing through the port due to relatively larger latent heat of injected liquid oxygen compared to the heat of release by combustion which depended on the burning surface area of PMMA.

  • PDF

Lattice Oxygen Activation in NiFe (Oxy)hydroxide using Se (셀레늄을 활용한 니켈철 (옥시)수산화물의 격자 산소 활성화)

  • Jo, Seunghwan;Sohn, Jung Inn
    • Korean Journal of Materials Research
    • /
    • v.32 no.8
    • /
    • pp.339-344
    • /
    • 2022
  • The lattice oxygen mechanism (LOM) is considered one of the promising approaches to overcome the sluggish oxygen evolution reaction (OER), bypassing -OOH* coordination with a high energetic barrier. Activated lattice oxygen can participate in the OER as a reactant and enables O*-O* coupling for direct O2 formation. However, such reaction kinetics inevitably include the generation of oxygen vacancies, which leads to structural degradation, and eventually shortens the lifetime of catalysts. Here, we demonstrate that Se incorporation significantly enhances OER performance and the stability of NiFe (oxy)hydroxide (NiFe) which follows the LOM pathway. In Se introduced NiFe (NiFeSe), Se forms not only metal-Se bonding but also Se-oxygen bonding by replacing oxygen sites and metal sites, respectively. As a result, transition metals show reduced valence states while oxygen shows less reduced valence states (O-/O22-) which is a clear evidence of lattice oxygen activation. By virtue of its electronic structure modulation, NiFeSe shows enhanced OER activity and long-term stability with robust active lattice oxygen compared to NiFe.

Effects on Physiological Activities Caused by Oxygen Deficiency and Exposure to Noxious Gases in SD Rats (Rat를 이용 산소 및 유해가스 노출에 따른 운동성 변화와 치사농도 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Kang, Min-Gu;Ye, Byeong-Jin
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.181-191
    • /
    • 2009
  • As an effort to prevent serious accidents involving oxygen deficiency and suffocation in confined spaces and to identify the causes of such accidents, the present study investigated relevant accidents and systems in Korea and other countries. This study also conducted a number of experiments at lethal concentration levels of oxygen deficiency using SD rats and observed the changes of experimental animals with humidity, organic gas (toluene), hydrogen sulfide, carbon monoxide and so on at the oxygen deficient environment. The results of the study are as follows. 1. The results from the experiment conducted using SD rats at lethal concentration levels of oxygen showed that there were no casualties at the 7% oxygen concentration level, but the mortality increase to 20% at 6% oxygen, it was jumped to 90% at 5% oxygen, and it was also dramatically reached 100% at 4% oxygen concentration. Therefore, 5.5% was calculated as the $LC_{50}$ (rat, 4hr) from these dose-response experiments with oxygen deficiency. 2. When we changed the level of toluene, $H_2S$, CO, humidity, and so on, in an oxygen deficient environment, it was observed that the small concentrations of $H_2S$ and CO make the highest effect on animals. In case of 350 ppm $H_2S$, it resulted in 30% mortality, and the 100% mortality was shown in 1,200 ppm CO concentration. The mortality increased as an oxygen deficient condition. However in the case of toluene up to 1,000 ppm, it were not affected with oxygen deficiency, and it did not indicate any significant differences in mortality as 20%, 90% humidities.

Effect of Oxygen on the Magnetic and Recording Characteristics of Magneto-Optical Disk (광자기 디스크의 기록 및 자기적 특성에 산소가 미치는 영향)

  • Choe, G.
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.3
    • /
    • pp.229-233
    • /
    • 1993
  • The effects of differential partial pressures of oxygen during sputtering on the magnetic and recording characteristics of magneto-optical disks were investigated. Different flows of oxygen were deliberately introduced into the sputtering chamber to have a variety of partial pressures of oxygen during sputtering. A residual gas analyzer was employed to monitor the oxygen peak before, during, and after sputtering and to estimate the reacted oxygen amount. Most of the oxygen introduced into the chamaber was reacted during sputtering. As the partial pressure of oxygen increased, the oxygen content of the TbFeCoCr film increased also. The oxygen appeared to be bound as Tb-O, effectively decreasing the magnetically active Tb content of the film The coercivity decreased but the squareness of the Kerr hysteresis loops was still excellent. The perpendicular anisotropy was not significantly affected by oxygen amount. The carrier-to-noise ratio, includi!1g the write power sensitivity and bias field sensitivity did not change too much with oxygen content in the film The disks sputtered with oxygen showed better bias field sensitivity with lower write power threshold than the disk sputtered without oxygen, due to high demagnetization during domain formation. No significant degradation of coercivity for the disk sputtered oxygen was observed during an accelerated aging test.

  • PDF