• Title/Summary/Keyword: oxygen

Search Result 15,897, Processing Time 0.057 seconds

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF

Study for Diagnostic Efficacy of Minibronchoalveolar Lavage in the Detection of Etiologic Agents of Ventilator-associated Pneumonia in Patients Receiving Antibiotics (항생제를 사용하고 있었던 인공호흡기 연관 폐렴환자에서의 원인균 발견을 위한 소량 기관지폐포세척술의 진단적 효용성에 관한 연구)

  • Moon, Doo-Seop;Lim, Chae-Man;Pai, Chik-Hyun;Kim, Mi-Na;Chin, Jae-Yong;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.321-330
    • /
    • 1999
  • Background : Early diagnosis and proper antibiotic treatment are very important in the management of ventilator-associated pneumonia (VAP) because of its high mortality. Bronchoscopy with a protected specimen brush (PSB) has been considered the standard method to isolate the causative organisms of VAP. However, this method burdens consumer economically to purchase a PSB. Another useful method for the diagnosis of VAP is quantitative cultures of aspirated specimens through bronchoscopic bronchoalveolar lavage (BAL), for which the infusion of more than 120 m1 of saline has been recommended for adequate sampling of a pulmonary segment. However, occasionally it leads to deterioration of the patient's condition. We studied the diagnostic efficacy of minibronchoalveolar lavage (miniBAL), which retrieves only 25 ml of BAL fluid, in the isolation of causative organisms of VAP. Methods: We included 38 consecutive patients (41 cases) suspected of having VAP on the basis of clinical evidence, who had received antibiotics before the bronchoscopy. The two diagnostic techniques of PSB and miniBAL, which were performed one after another at the same pulmonary segment, 'were compared prospectively. The cut-off values for quantitative cultures to define causative bacteria of VAP were more than $10^3$ colony-forming units (cfu)/ml for PSB and more than $10^4$ cfu/ml for BAL. Results: The amount of instilled normal saline required to retrieve 25 ml of BAL fluid was $93{\pm}32 ml$ (mean${\pm}$SD). The detection rate of causative agents was 46.3% (19/41) with PSB and 43.9% (18/41) with miniBAL. The concordance rate of PSB and miniBAL in the bacterial culture was 85.4% (35/41). Although arterial blood oxygen saturation dropped significantly (p<0.05) during ($92{\pm}10%$) and 10 min after ($95{\pm}3%$) miniBAL compared with the baseline ($97{\pm}3%$), all except 3 cases were within normal ranges. The significantly elevated heart rate during ($l25{\pm}24$/min, p<0.05) miniBAL compared with the baseline ($1l1{\pm}22$/min) recovered again in 10 min after ($111{\pm}26$/min) miniBAL. Transient hypotension was developed during the procedure in two cases. The procedure was stopped in one case due to atrial flutter. Conclusion: MiniBAL is a safe and effective technique to detect the causative organisms of VAP.

  • PDF

The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation (기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성)

  • Na, Joo-Ock;Lim, Chae-Man;Shim, Tae-Sun;Park, Joo-Hun;Lee, Ki-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.350-362
    • /
    • 1999
  • Background: Acute Respiratory failure which is developed after extubation in the weaning process from mechanical ventilation is an important cause of weaning failure. Once it was developed, endotracheal reintubation has been done for respiratory support. Noninvasive Positive Pressure Ventilation (NIPPV) has been used in the management of acute or chronic respiratory failure, as an alternative to endotracheal intubation, using via nasal or facial mask. In this study, we evaluated the usefulness of NIPPV as an alternative method of reintubation in patients who developed acute respiratory failure after extubation. Method: We retrospectively analyzed thirty one patients(eighteen males and thirteen females, mean ages $63\pm13.2$ years) who were developed acute respiratory failure within forty eight hours after extubation, or were extubated unintentionally at medical intensive care unit(MICU) of Asan Medical Center. NIPPV was applied to the patients. Ventilatory mode of NIPPV, level of ventilatory support and inspiratory oxygen concentration were adjusted according to the patient condition and results of blood gas analysis by the attending doctors at MICU. NIPPV was completely weaned when the patients maintained stable clinical condition under 8 $cmH_2O$ of pressure support level. Weaning success was defined as maintenance of stable spontaneous breathing more than forty eight hours after discontinuation of NIPPV. Respiratory rate, heart rate, arterial blood gas analysis, level of pressure support, and level of PEEP were monitored just before extubation, at thirty minutes, six hours, twenty four hours after initiation of NIPPV. They were also measured at just before weaning from NIPPV in success group, and just before reintubation in failure group. Results: NIPPV was successfully applied to thirty-one patients of thirty-two trials and one patient could not tolerated NIPPV longer than thirty minutes. Endotracheal reintubation was successfully obviated in fourteen patients (45%) among them. There was no difference in age, sex, APACHE III score on admission at MICU, duration of intubation, interval from extubation to initiation of NIPPV, baseline heart rate, respiratory rate, arterial blood gas, and $PaO_2/FiO_2$ between the success and the failure group. Heart rate and respiration rate were significantly decreased with increase $SaO_2$ after thirty minutes of NIPPV in both groups(p<0.05). However, in the patients of failure group, heart rate and respiratory rate were increased again with decrease in $SaO_2$ leading to endotracheal reintubation. The success rate of NIPPV treatment was significantly higher in the patients with COPD compared to other diseases(62% vs 39%) (p=0.007). The causes of failure were deterioration of arterial blood gas without aggravation of underlying disease(n=9), aggravation of undelying disease(n=5), mask intolerance(n=2), and retained airway secretion(n=l). Conclusion: NIPPV would be a useful therapeutic alternative which can avoid reintubation in patient who developed acute respiratory failure after extubation.

  • PDF

The Evaluation of IL-8 in the Serum of Pneumoconiotic patients (진폐증 환자에서의 혈청내 IL-8 농도)

  • Ahn, Hyeong Sook;Kim, Ji Hong;Chang, Hwang Sin;Kim, Kyung Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.945-953
    • /
    • 1996
  • Background : Many acute and chronic lung diseases including pneumoconiosis are characterized by the presence of increased numbers of activated macrophages. These macrophages generate several inflammatory cell chemoattractants, by which neutrophil migrate from vascular compartment to the alveolar space. Recruited neutrophils secrete toxic oxygen radicals or proteolytic enzymes and induce inflammatory response. Continuing inflammatory response results in alteration of the pulmonary structure and irreversible fibrosis. Recently, a polypeptide with specific neutrophil chemotactic activity, interleukin-8(IL-8), has been cloned and isolated from a number of cells including : monocytes, macrophages and fibroblasts. IL-1 and/or TNF-${\alpha}$ preceded for the synthesis of IL-8, and we already observed high level of IL-1 and TNF-${\alpha}$ in the pneumoconioses. So we hypothesized that IL-8 may be a central role in the pathogenesis of pneumoconiosis. In order to evaluate the clinical utility of IL-8 as a biomarker in the early diagnosis of pneumoconiosis, we investigated the increase of IL-8 in the pneumoconiotic patient and the correlation between IL-8 level and progression of pneumoconiosis. Method : We measured IL-8 in the serum of 48 patients with pneumoconiosis and 16 persons without dust exposure history as a control group. Pneumoconiotic cases were divided into 3 groups according to ILO Classification : suspicious group(n=16), small opacity group(n=16) and large opacity group(n=16). IL-8 was measured by a sandwich enzytne immunoassay technique. All data were expressed as the $mean{\pm}standard$ deviation. Results: 1) The mean value of age was higher in the small opacity and large opacity group than comparison group, but smoking history was even. Duration of dust exposure was not different among 3 pneumoconiosis groups. 2) IL-8 level was $70.50{\pm}53.63pg/m{\ell}$ in the suspicious group, $107.50{\pm}45.88pg/m{\ell}$ in the small opacity group, $132.50{\pm}73.47pg/m{\ell}$ in the large opacity group and $17.85{\pm}33.85pg/m{\ell}$ in the comparison group. IL-8 concentration in all pneumoconiosis group was significant higher than that in the comparison group(p<0.001). 3) IL-8 level tended to increase with the progression of pneumoconiosis. Multiple comparison test using Anova/Scheffe analysis showed a significant difference between suspicious group and large opacity group(p<0.05). 4) The level of IL-8 was correlated with the progression of pneumoconiosis(r=0.4199, p<0.05). Conclusion : IL-8 is thought to be a good biomarker for the early diagnosis of pneumoconiosis.

  • PDF

Plasma Activity of Lysosomal Enzymes in Active Pulmonary Tuberculosis (활동성 폐결핵 환자에서 혈중 리소솜 효소의 활성도)

  • Koh, Youn-Suck;Choi, Jeong-Eun;Kim, Mi-Kyung;Lim, Chae-Man;Kim, Woo-Sung;Chi, Hyun-Sook;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.646-653
    • /
    • 1995
  • Background: The confirmative diagnosis of pulmonary tuberculosis(Tb) can be made by the isolation of Mycobacterium Tuberculosis(MTb) in the culture of the sputum, respiratory secretions or tissues of the patients, but positive result could not always be obtained in pulmonary Tb cases. Although there are many indirect ways of the diagnosis of Tb, clinicians still experience the difficulty in the diagnosis of Tb because each method has its own limitation. Therefore development of a new diagnostic tool is clinically urgent. It was reported that silica cause some lysosomal enzymes to be released from macrophages in vitro and one of these enzymes is elevated in workers exposed to silica dust and in silicotic subjects. In pulmonary Tb, alveolar macrophages are known to be activated after ingestion of MTb. Activated macrophages can kill MTb through oxygen free radical species and digestive enzymes of lysosome. But if macrophages allow the bacilli to grow intracellularly, the macrophages will die finally and local lesion will enlarge. Then it is assumed that the lysosomal enzymes would be released from the dead macrophages. The goal of this investigation was to determine if there are differences in the plasma activities of lysosomal enzymes, ($\beta$-glucuronidase(GLU) and $\beta$-N-acetyl glucosaminidase(NAG), among the groups of active and inactive pulmonary Tb and healthy control, and to see if there is any possibility that the plasma activity of GLU and NAG can be used as diagnostic indicies of active pulmonary Tb. Methods: The plasma were obtained from 20 patients with bacteriologically proven active pulmonary Tb, 15 persons with inactive Tb and 20 normal controls. In 10 patients with active pulmonary Tb, serial samples after 2 months of anti-Tb medications were obtained. Plasma GLU and NAG activities were measured by the fluorometric methods using 4-methylumbelliferyl substrates. All data are expressed as the mean $\pm$ the standard error of the mean. Results: The activites of GLU and NAG in plasma of the patients with active Tb were $21.52{\pm}3.01$ and $325.4{\pm}23.37$(nmol product/h/ml of plasma), respectively. Those of inactive pulmonary Tb were $24.87{\pm}3.78$, $362.36{\pm}33.92$ and those of healthy control were $25.45{\pm}4.05$, $324.44{\pm}28.66$(nmol product/h/ml of plasma), respectively. There were no significant differences in the plasma activities of both enzymes among 3 groups. The plasma activities of GLU at 2 months after anti-Tb medications were increased($42.18{\pm}5.94$ nmol product/h/ml of plasma) in the patients with active pulmonary Tb compared with that at the diagnosis of Tb(P-value <0.05). Conclusion: The results of the present investigation suggest that the measurement of the plasma activities of GLU and NAG in the patients with active pulmonary Tb could not be a useful method for the diagnosis of active Tb. Further investigation is necessary to define the reasons why the plasma activities of the GLU was increased in the patients with active pulmonary Tb after Tb therapy.

  • PDF

Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung (토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구)

  • An, Chang-Hyeok;Koh, Young-Min;Park, Chong-Wung;Suh, Gee-Young;Koh, Won-Jung;Lim, Sung-Yong;Kim, Cheol-Hong;Ahn, Young-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.14-23
    • /
    • 2002
  • Background: The opitmal ventilator setting during partial liquid ventilation(PLV) is controversial. This study investigated the effects of various gas exchange parameters during PLV in normal rabbit lungs in order to aid in the development of an optimal ventilator setting during PLV. Methods: Seven New-Zealand white rabbits were ventilated in pressure-controlled mode with the following settings; tidal volume($V_T$) 8 mL/kg, positive end-expiratory pressure(PEEP) 4 $cmH_2O$, inspiratory-to-expiratory ratio(I:E ratio) 1:2, fraction of inspired oxygen($F_TO_2$) 1.0. The respiration rate(RR) was adjusted to keep $PaCO_2$ between 35~45 mmHg. The ventilator settings were changed every 30 min in the following sequence : (1) Baseline, as the basal ventilator setting, (2) Inverse ratio, I:E ratio 2:1, (3) high PEEP, adjust PEEP to achieve the same mean inspiratory pressure (MIP) as in the inverse ratio, (4) High $V_T$, $V_T$ 15 mL/kg, (5) high RR, the same minute ventilation (MV) as in the High $V_T$. Subsequently, the same protocol was repeated after instilling 18 mL/kg of perfluorodecalin for PLV. The parameters of gas exchange, lung mechanics, and hemodynamics were examined. Results: (1) The gas ventilation(GV) group showed no significant changes in the $PaO_2$ at all phases. The $PaCO_2$ was lower and the pH was higher at the high $V_T$ and high RR phases(p<0.05). No significant changes in the lung mechanics and hemodynamics parameters were observed. (2) The baseline $PaO_2$ for the PLV was $312{\pm}$ mmHg. This was significantly lower when decreased compared to the baseline $PaO_2$ for GV which was $504{\pm}81$ mmHg(p=0.001). During PLV, the $PaO_2$, was significantly higher at the high PEEP($452{\pm}38$ mmHg) and high $V_T$ ($461{\pm}53$ mmHg) phases compared with the baseline phase. However, it did not change significantly during the inverse I:E ratio or the high RR phases. (3) The $PaCO_2$ was significantly lower at high $V_T$ and RR phases for both the GV and PLV. During the PLV, $PaCO_2$ were significantly higher compared to the GV (p<0.05). (4) There were no important or significant changes in of baseline and high RR phases lung mechanics and hemodynamics parameters during the PLV. Conclusion: During PLV in the normal lung, adequate $V_T$ and PEEP are important for optimal oxygenation.

Effect of Sanitation Treatment of Extending Shelf-life on Fresh Poultry Meats (계육(鷄肉)의 유통기간연장(流通期間延長)을 위(爲)한 위생처리방법(衛生處理方法)에 관(關)한 연구(硏究))

  • Cho, M.J.;Jang, P.H.;Park, K.B.;Lee, B.M.
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.291-300
    • /
    • 1982
  • In order to develop effective and simple sanitation method for the extention of shelf-life of fresh poultry meat, the effect of sanitizers, sanitation methods and packaging materials on the extention of shelf-life of poultry meats was observed at the $4^{\circ}C$ and room temp$(10{\sim}20^{\circ}C)$. The results are summarized as follows: 1. The autochonous skin microflora of poultry, before processing, were believed to be removed or killed during the scalding and plucking, and exposed dermal tissue was contaminated by microorganisms from the subsequent stages of processing. 2. In the final stage of poultry processing, total viable counts of microorganisms and coliforms were averaged to $3.5{\times}10^4/cm^2$ and $400/cm^2$, respectively. 3. The refrigerated shelf-life of fresh whole poultry carcasses at $3\;to\;4^{\circ}C$ was extended to 7 to 16 days compared to control with the various treatments of some sanitizers by dipping freshly chilled carcasses for 5 min or spraying 1 liter of sanitizers per carcasses. In the case of storage at $10\;to\;15^{\circ}C$, the shelf-life of poultry carcasses was extended to one to two days by the sanitation treatments compared to control. 4. Spraying sanitation was more effective than dipping sanitation, and 5 minutes dipping and one liter spraying per carcass were enough for effective sanitation of poultry carcasses in most sanitizers. 5. The packaging with an oxygen impermeable polyvinylidene chloride extended the shelf-life to 10 days and 5 days with polyethylene compared to control. When poultry carcasses were sanitized by continuous spraying with one liter of 30 ppm of chlorine and another one liter of 5% of potassium sorbate, packaged with polyvinylidene chlorlde were extended to about 30 days compared to control.

  • PDF

Effect of Hydrogen Peroxide Enema on Recovery of Carbon Monoxide Poisoning (과산화수소 관장이 급성 일산화탄소중독의 회복에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.53-63
    • /
    • 1986
  • Carbon monoxide(CO) poisoning has been one of the major environmental problems because of the tissue hypoxia, especially brain tissue hypoxia, due to the great affinity of CO with hemoglobin. Inhalation of the pure oxygen$(0_2)$ under the high atmospheric pressure has been considered as the best treatment of CO poisoning by the supply of $0_2$ to hypoxic tissues with dissolved from in plasma and also by the rapid elimination of CO from the carboxyhemoglobin(HbCO). Hydrogen peroxide $(H_2O_2)$ was rapidly decomposed to water and $0_2$ under the presence of catalase in the blood, but the intravenous administration of $H_2O_2$ is hazardous because of the formation of methemoglobin and air embolism. However, it was reported that the enema of $H_2O_2$ solution below 0.75% could be continuously supplied $0_2$ to hypoxic tissues without the hazards mentioned above. This study was performed to evaluate the effect of $H_2O_2$ enema on the elimination of CO from the HbCO in the recovery of the acute CO poisoning. Rabbits weighting about 2.0 kg were exposed to If CO gas mixture with room air for 30 minutes. After the acute CO poisoning, 30 rabbits were divided into three groups relating to the recovery period. The first group T·as exposed to the room air and the second group w·as inhalated with 100% $0_2$ under 1 atmospheric pressure. The third group was administered 10 ml of 0.5H $H_2O_2$ solution per kg weight by enema immediately after CO poisoning and exposed to the room air during the recovery period. The arterial blood was sampled before and after CO poisoning ana in 15, 30, 60 and 90 minutes of the recovery period. The blood pH, $Pco_2\;and\;Po_2$ were measured anaerobically with a Blood Gas Analyzer and the saturation percentage of HbCO was measured by the Spectrophotometric method. The effect of $H_2O_2$ enema on the recovery from the acute CO poisoning was observed and compared with the room air group and the 100% $0_2$ inhalation group. The results obtained from the experiment are as follows: The pH of arterial blood was significantly decreased after CO poisoning and until the first 15 minutes of the recovery period in all groups. Thereafter, it was slowly increased to the level of the before CO poisoning, but the recovery of pH of the $H_2O_2$ enema group was more delayed than that of the other groups during the recovery period. $Paco_2$ was significantly decreased after CO poisoning in all groups. Boring the recovery Period, $Paco_2$ of the room air group was completely recovered to the level of the before CO Poisoning, but that of the 100% $O_2$ inhalation group and the $H_2O_2$ enema group was not recovered until the 90 minutes of the recovery period. $Paco_2$ was slightly decreased after CO poisoning. During the recovery Period, it was markedly increased in the first 15 minutes and maintained the level above that before CO Poisoning in all groups. Furthermore $Paco_2$ of the $H_2O_2$ enema group was 102 to 107 mmHg and it was about 10 mmHg higher than that of the room air group during the recovery period. The saturation percentage of HbCO was increased up to the range of 54 to 72 percents after CO poisoning and in general it was generally diminished during the recovery period. However in the $H_2O_2$ enema group the diminution of the saturation percentage of HbCO was generally faster than that of the 100% $O_2$ inhalation group and the room air group, and its diminution in the 100% $O_2$ inhalation group was also slightly faster than that of the room air group at the relatively later time of the recovery period. In conclusion, the enema of 0.5% $H_2O_2$ solution is seems to facilitate the elimination of CO from the HbCO in the blood and increase $Paco_2$ simultaneously during the recovery period of the acute CO poisoning.

  • PDF

Mineralogy and Geochemistry of the Jeonheung and Oksan Pb-Zn-Cu Deposits, Euiseong Area (의성(義城)지역 전흥(田興) 및 옥산(玉山) 열수(熱水) 연(鉛)-아연(亞鉛)-동(銅) 광상(鑛床)에 관한 광물학적(鑛物學的)·지화학적(地化學的) 연구(硏究))

  • Choi, Seon-Gyu;Lee, Jae-Ho;Yun, Seong-Taek;So, Chil-Sup
    • Economic and Environmental Geology
    • /
    • v.25 no.4
    • /
    • pp.417-433
    • /
    • 1992
  • Lead-zinc-copper deposits of the Jeonheung and the Oksan mines around Euiseong area occur as hydrothermal quartz and calcite veins that crosscut Cretaceous sedimentary rocks of the Gyeongsang Basin. The mineralization occurred in three distinct stages (I, II, and III): (I) quartz-sulfides-sulfosalts-hematite mineralization stage; (II) barren quartz-fluorite stage; and (III) barren calcite stage. Stage I ore minerals comprise pyrite, chalcopyrite, sphalerite, galena and Pb-Ag-Bi-Sb sulfosalts. Mineralogies of the two mines are different, and arsenopyrite, pyrrhotite, tetrahedrite and iron-rich (up to 21 mole % FeS) sphalerite are restricted to the Oksan mine. A K-Ar radiometric dating for sericite indicates that the Pb-Zn-Cu deposits of the Euiseong area were formed during late Cretaceous age ($62.3{\pm}2.8Ma$), likely associated with a subvolcanic activity related to the volcanic complex in the nearby Geumseongsan Caldera and the ubiquitous felsite dykes. Stage I mineralization occurred at temperatures between > $380^{\circ}C$ and $240^{\circ}C$ from fluids with salinities between 6.3 and 0.7 equiv. wt. % NaCl. The chalcopyrite deposition occurred mostly at higher temperatures of > $300^{\circ}C$. Fluid inclusion data indicate that the Pb-Zn-Cu ore mineralization resulted from a complex history of boiling, cooling and dilution of ore fluids. The mineralization at Jeonheung resulted mainly from cooling and dilution by an influx of cooler meteoric waters, whereas the mineralization at Oksan was largely due to fluid boiling. Evidence of fluid boiling suggests that pressures decreased from about 210 bars to 80 bars. This corresponds to a depth of about 900 m in a hydrothermal system that changed from lithostatic (closed) toward hydrostatic (open) conditions. Sulfur isotope compositions of sulfide minerals (${\delta}^{34}S=2.9{\sim}9.6$ per mil) indicate that the ${\delta}^{34}S_{{\Sigma}S}$ value of ore fluids was ${\approx}8.6$ per mil. This ${\delta}^{34}S_{{\Sigma}S}$ value is likely consistent with an igneous sulfur mixed with sulfates (?) in surrounding sedimentary rocks. Measured and calculated hydrogen and oxygen isotope values of ore-forming fluids suggest meteoric water dominance, approaching unexchanged meteoric water values. Equilibrium thermodynamic interpretation indicates that the temperature versus $fs_2$ variation of stage I ore fluids differed between the two mines as follows: the $fs_2$ of ore fluids at Jeonheung changed with decreasing temperature constantly near the pyrite-hematite-magnetite sulfidation curve, whereas those at Oksan changed from the pyrite-pyrrhotite sulfidation state towards the pyrite-hematite-magnetite state. The shift in minerals precipitated during stage I also reflects a concomitant $fo_2$ increase, probably due to mixing of ore fluids with cooler, more oxidizing meteoric waters. Thermodynamic consideration of copper solubility suggests that the ore-forming fluids cooled through boiling at Oksan and mixing with less-evolved meteoric waters at Jeonheung, and that this cooling was the main cause of copper deposition through destabilization of copper chloride complexes.

  • PDF

Uranium Adsorption Properties and Mechanisms of the WRK Bentonite at Different pH Condition as a Buffer Material in the Deep Geological Repository for the Spent Nuclear Fuel (사용후핵연료 심지층 처분장의 완충재 소재인 WRK 벤토나이트의 pH 차이에 따른 우라늄 흡착 특성과 기작)

  • Yuna Oh;Daehyun Shin;Danu Kim;Soyoung Jeon;Seon-ok Kim;Minhee Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.603-618
    • /
    • 2023
  • This study focused on evaluating the suitability of the WRK (waste repository Korea) bentonite as a buffer material in the SNF (spent nuclear fuel) repository. The U (uranium) adsorption/desorption characteristics and the adsorption mechanisms of the WRK bentonite were presented through various analyses, adsorption/desorption experiments, and kinetic adsorption modeling at various pH conditions. Mineralogical and structural analyses supported that the major mineral of the WRK bentonite is the Ca-montmorillonite having the great possibility for the U adsorption. From results of the U adsorption/desorption experiments (intial U concentration: 1 mg/L) for the WRK bentonite, despite the low ratio of the WRK bentonite/U (2 g/L), high U adsorption efficiency (>74%) and low U desorption rate (<14%) were acquired at pH 5, 6, 10, and 11 in solution, supporting that the WRK bentonite can be used as the buffer material preventing the U migration in the SNF repository. Relatively low U adsorption efficiency (<45%) for the WRK bentonite was acquired at pH 3 and 7 because the U exists as various species in solution depending on pH and thus its U adsorption mechanisms are different due to the U speciation. Based on experimental results and previous studies, the main U adsorption mechanisms of the WRK bentonite were understood in viewpoint of the chemical adsorption. At the acid conditions (<pH 3), the U is apt to adsorb as forms of UO22+, mainly due to the ionic bond with Si-O or Al-O(OH) present on the WRK bentonite rather than the ion exchange with Ca2+ among layers of the WRK bentonite, showing the relatively low U adsorption efficiency. At the alkaline conditions (>pH 7), the U could be adsorbed in the form of anionic U-hydroxy complexes (UO2(OH)3-, UO2(OH)42-, (UO2)3(OH)7-, etc.), mainly by bonding with oxygen (O-) from Si-O or Al-O(OH) on the WRK bentonite or by co-precipitation in the form of hydroxide, showing the high U adsorption. At pH 7, the relatively low U adsorption efficiency (42%) was acquired in this study and it was due to the existence of the U-carbonates in solution, having relatively high solubility than other U species. The U adsorption efficiency of the WRK bentonite can be increased by maintaining a neutral or highly alkaline condition because of the formation of U-hydroxyl complexes rather than the uranyl ion (UO22+) in solution,and by restraining the formation of U-carbonate complexes in solution.