• Title/Summary/Keyword: oxidation induction time

Search Result 38, Processing Time 0.025 seconds

Growth mechanism of anodic oxide for MCT passivation (MCT 표면보호를 위한 양극산화막 성장)

  • 정진원;왕진석
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.352-356
    • /
    • 1995
  • Native oxide layer on MCT (HgCdTe) has been grown uniformly in H$\_$2/O$\_$2/ electrolyte through anodic oxidation method. It has been determined that anodic oxidation of HgCdTe in H$\_$2/O$\_$2/ electrolyte proceeds immediately with the input of constant currents without any induction time required for anodic oxideation in KOH electrolyte. Oxide layer with the resistivity of 2*10$\^$10/.ohm.cm and the refractive index of 2.1 suggested the possibility of well matching combination layer with ZnS for MCT MIS device. XPS results indicated that the major components of oxide layer grown in H202 solution is TeO$\_$2/ with the possibility of small amounts of CdTeO$\_$3/.

  • PDF

Failure Mechanism and Long-Term Hydrostatic Behavior of Linear Low Density Polyethylene Tubing (선형저밀도 폴리에틸렌 튜빙의 파손 메커니즘과 장기 정수압 거동)

  • Weon, Jong-Il;Chung, Yu-Kyoung;Shin, Sei-Moon;Choi, Kil-Yeong
    • Polymer(Korea)
    • /
    • v.32 no.5
    • /
    • pp.440-445
    • /
    • 2008
  • The failure mechanism and failure morphology of linear low density polyethylene (LLDPE) tubing under hydrostatic pressure were investigated. Microscopic observations using video microscope and scanning electron microscope indicate that the failure mode is a brittle fracture including cracks propagated from inner wall to outer wall. In addition, oxidation induction time and Fourier transform infrared spectroscopy results show the presence of exothermic peak and the increase in carbonyl index on the surface of fractured LLDPE tubing, due to thermal-degradation. An accelerated life test methodology and testing system for LLDPE tubing are developed using the relationship between stresses and life characteristics by means of thermal acceleration. Statistical approaches using the Arrhenius model and Weibull distribution are implemented to estimate the long-term life time of LLDPE tubing under hydrostatic pressure. Consequently, the long-term life time of LLDPE tubing at the operating temperature of $25^{\circ}C$ could be predicted and also be analyzed.

Evaluation of thymolphthalein-grafted graphene oxide as an antioxidant for polypropylene

  • Bagheripour-Asl, Mona;Jahanmardi, Reza;Tahermansouri, Hasan;Forghani, Erfan
    • Carbon letters
    • /
    • v.25
    • /
    • pp.60-67
    • /
    • 2018
  • In the present work, capability of thymolphthalein-grafted graphene oxide, which was successfully synthesized in this study, in stabilization of polypropylene against thermal oxidation were investigated and compared with that of SONGNOX 1010, a commercially used phenolic antioxidant for the polymer. The modified graphene oxide were incorporated into polypropylene via melt mixing. State of distribution of the nanoplatelets in the polymer matrix was examined using scanning electron microscopy and was shown to be homogeneous. Measurements of oxidation onset temperature and oxidative induction time revealed that thymolphthalein-grafted graphene oxide modifies thermo-oxidative stability of the polymer in the melt state remarkably. However, the efficiency of the nanoplatelets in stabilization of polypropylene against thermal oxidation in melt state was shown to be inferior to that of SONGNOX 1010. Furthermore, oven ageing experiments followed by Fourier transform infrared spectroscopy showed that the modified graphene oxide improves thermo-oxidative stability of the polymer strongly in the solid state, so that its stabilization efficiency is comparable to that of SONGNOX 1010.

Inhibitory Effect of Perilla Sprouts Extracts on Oxidation of Perilla Oil (들깨유의 산화에 대한 들깨 발아 싹 추출물의 억제효과)

  • Kim, Seok-Joong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.330-338
    • /
    • 2012
  • During 10 days germination of perilla seeds for sprouts preparation, the changes of proximate composition and antioxidant activities were monitored, and the inhibitory effect of sprouts extracts on perilla oil oxidation was also studied. The moisture content in seeds(2.9%) was increased to 9.2% in sprouts at 10 days while crude ash content wasn't significantly. The crude fat and protein contents were reduced from 46.8% and 20.7% in seeds to 18.2% and 18.3% in sprouts, respectively, but reducing sugar and fiber contents increased from 2.2% and 14.8% to 12.8% and 22.4%, respectively. Compared with perilla leaf, sprouts at 10 days contained more fat, carbohydrate, reducing sugar, and fiber while less moisture, ash, and protein. Antioxidant activities during germination were increased and reached to maximum at 8 days in which Trolox equivalent antioxidant capacity(TEAC) based on DPPH and ABTS radical scavenging were 133.1 and 136.8 Trolox eq. mmol/kg, respectively, and ferric ion reducing power(FRAP) was 399.3 Fe(II) eq. mmol/kg. Polyphenol content(19.2 g/kg) was maximum at this stage, too. Perilla leaf showed similar TEAC but higher FRAP than the sprouts. When methanol extract of sprouts at 8 days was added to perilla oil, the oil oxidation was delayed in dose dependent manner. The induction time for oxidation was extended about 2.8 times by adding 2.5%(w/w) extract, that is, from 1.67 hr(control) to 4.62 hr. This induction time corresponded to 38% level of that of perilla oil containing 2.5% BHT.

Oxidation Behavior of $UO_2$ Fuel ($UO_2$ 핵연료의 산화거동)

  • Kang Kweon-Ho;Moon Heung-Soo;Na Sang-Ho;Oh Se-Yong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.8-13
    • /
    • 2006
  • The oxidation behavior of $UO_2$, pellet was studied using an XRD and a thermogravimetric analyzer in the temperature range from 573 to 873 K and in the density range from 94.64 to 99.10% of theoretical density in air. It was found from the XRD study that $UO_2$ was completely converted to $U_3O_8$ in this experimental temperature range. The formation of $U_3O_8$ displays sigmoidal reaction kinetics. The oxidation rate was reduced with density. Induction time for the oxidation of $UO_2$ was delayed with density because of open pore formed in surface of $UO_2$ pellet. The activation energy for oxidation of $UO_2$ was determined to be 89.54 kJ/mol and 34.40 kJ/mol in the temperature range from 573 to 723 K and from 723 to 873 K, respectively.

Induction of DNA Breakage by the Hot-water Extracts of Fructus Chaenomelis (Chaenomeles sinensis Koehne)

  • Nam, Seok Hyun;Chon, Dae Jin;Kang, Mi Young
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.3
    • /
    • pp.156-160
    • /
    • 2000
  • The possible mechanism of the DNA strand breaking activity of the hot-water extract of Fructus Chaenomelis (dried fruit of Chaenomeles sinensis) in a closed circular duplex replica form DNA (RFI DNA) was studied through agarose gel electrophresis under various conditions. Induction of DNA strand scission by the hot-water extract of C. sinensis occurred in dose and time-dependent manners. $Cu^{2+}$ was indispensable for the induction of DNA strand breakage. Exogeneous chelating agents inhibited the DNA breaking activity, conforming the catalytic action of $Cu^{2+}$ on generation of free radicals responsible for oxidative damage. Antioxidant enzymes and some radical scavengers were used to investigate the major radical species triggering the DNA strand scission, demonstrating that a highest inhibitory activity was found in the presence of catalase, while less in the presence of tiron (a scavenger for superoxide radical), 2-aminoethyl-isothiuroniumbromide-HBr, cysteamine (scavengers for hydroxyl radical), and 1,4-diazabicyclo [2,2,2] octane (a scavenger for singlet oxygen) in decreasing order. The findings implied that oxygen radical species generated in presence of transition divalent cation during the oxidation of some compounds contained in the hot-water extract of C. sinensis is mainly responsible for inducing genotoxicity.

  • PDF

A Study on the Durability of the Polyethylene Coatings for Underground Pipeline (매설강관용 폴리에틸렌 피복재의 내구성)

  • Ryu, Keun-chang;Lee, Seong-Min;Kho, Young-Tai;Argent, Colin
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.40-46
    • /
    • 2002
  • This study has been carried out to evaluate the reliability by examining the properties related to durability of commercially available coating systems in domestic. For this purpose slow crack growth resistance and oxidative induction time tests were introduced, which have been accepted as durability parameters in polyethylene pipes with low pressure. Based upon the experimental results on these parameters, desirable minimum values are proposed for the durability enhancement of the polyethylene coatings.

  • PDF

Evaluation of Radiation Degradation or Crosslinked Polyethylene using TGA (TGA를 이용한 가교폴리에틸렌의 방사선 열화 평가)

  • Lee, Chung;Kim, Ki-Yup;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • Radiation degradation of crosslinked polyethylene(XLPE) was investigated using thermogravimetric analysis(TGA), The results of TGA were compared with FT-IR, melting temperature, oxidation induction time, and elongation at break on the XLPE exposed by $\gamma$-ray. 5% decomposition temperature of $\gamma$-ray irradiated XLPE showed similar tendencies with the case of elongation at break. Both properties agreed below 1000 KGy, however, did not show any remarkable characteristics above 1000 kGy, these properties can be useful to evaluate the radiation degradation of XLPE for only low irradiated region. Above 1000 kGy, the thermal decomposition activation energy showed decreased, on the contrary, increasing below 1000 kGy. Compared with FT-IR spectrum of irradiated XLPE, it was confirmed that the oxidation reaction was still occurring below 1000 kGy. Radiation degradation of XLPE was dependent upon the irradiation doses, TGA can be a useful tool to evaluate the degradation.

Effects of Hot Water on the Aging of URD Power Cables (지중 배편케이블의 열화에 미치는 온수의 영향)

  • 한재홍;송일근;김주용;이병성;정종욱
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.609-614
    • /
    • 2002
  • In this study, we investigated the effects of hot water on the aging of URD power cables due to the hot water ingress to power distribution lines. Hot water contacted and non-contacted cables extracted from 2 distribution lines were characterized by the measurement of oxidation induction time(OIT) and chemical structure. In OIT measurement, hot water contacted cables showed the shorter OIT than non-contacted ones. Especially, hot water contacted insulation layer near insulation shield showed the shortest OIT. In chemical structure analysis, the antioxidant content was decreased and the acid concentration was increased by hot water ingress. From this results, it can be concluded that the hot water ingress to power cable may be accelerate the aging by means of antioxidant consumption.

Characterization of Field-Aged Polymer Insulators for Distribution Power Systems (배전용 폴리머애자의 현장열화 특성평가)

  • 이병성;김찬영;한재홍
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF