• Title/Summary/Keyword: overall conversion efficiency

Search Result 133, Processing Time 0.026 seconds

New Polymer Electrolytes for Solid State Dye-Sensitized Solar Cells (고분자 전해질을 이용한 고체형 염료감응 태양전지)

  • Kang, Yong-Soo;Lee, Yong-Gun;Kang, Moon-Sung;Kim, Jong-Hak;Char, Kook-Chen
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.231-234
    • /
    • 2007
  • The solid state dye-sensitized saolrc cells (DSSCs) employing polymer electrolytes show high overall energy conversion efficiency as high as 4.5% at 1 sun conditions. The improved efficiency may be primarily due to the enlarged interfacial contact area between the electrolyte and dyes in addition to the increased ionic conductivity, which were done by utilizing liquid oligomers, followed by in situ self-solidification, to form the solid DSSCs "Oligomer Approach". The effect of the charge transfer resistance at the counter electrode side on the effciency has also been investigated.

  • PDF

Effect of the Linkers Between 9,9-Dimethylfluorenyl Terminal Moiety and a-Cyanoacrylic Acid Anchor on the $\lambda_{max}$ of the UV Spectrum and the Energy Efficiency in Dye-Sensitized Solar Cell (DSSC)

  • Lee, Min-U;Cha, Su-Bong;Lee, Jeong-Ryeol;Park, Se-Ung;Kim, Gyeong-Gon;Park, Nam-Gyu;Lee, Deok-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.316-316
    • /
    • 2010
  • Six metal-free organic dyes having thiophene (1), benzene-thiophene (2), thiophene-benzene (3), thiophene-pyridine(4), thiophene-thiophene (5), and pyridine (6) linkers between 9,9-dimethylfluorenyl terminal group and $\alpha$-cyanoacrylic acid anchor were synthesized. Among them, organic dye 5 showed the longest ${\lambda}}max$ value (424 nm) in UV-Vis absorption spectrum, better incident monochromatic photon-to-current conversion efficiency (IPCE), highest short circuit photocurrent density (JSC, 9.33 mA2/cm2), and highest overall conversion efficiency ($\eta$, 3.91%).

  • PDF

Document Imaging & Conversion And the Application of Standards

  • Gamble, Troy A.
    • Proceedings of the CALSEC Conference
    • /
    • 1998.10a
    • /
    • pp.141-148
    • /
    • 1998
  • ㆍ Design Creation is More Efficient ㆍ Large Shared Body of Knowledge Created and Maintained...Reducing Training Time, Re-Training, Costs and Design Efforts. ㆍ Electronic Data Easier to Exchange and Integrate. An Overall Increase in Efficiency, Savings and Competitiveness Will be Achieved(omitted)

  • PDF

Methane Production and Nitrogen Removal from Piggery Wastewater in the TPAD Coupled with BNR Process (질소제거공정과 결합한 2상 혐기성 소화공정에서 돈분폐수의 메탄생성 및 질소제거)

  • Park, Noh-Back;Park, Sang-Min;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.18-25
    • /
    • 2009
  • Nitrogen removal and methane production from piggery wastewater were investigated in two-phase anaerobic digestion (TPAD) coupled with biological nitrogen removal (BNR) process at $35^{\circ}C$. Methane production rate was about $0.7L/L{\cdot}day$ at organic loading rate (OLR) of $1.2g{\cdot}TCOD/L{\cdot}day$ in methanogenic UASB. Conversion efficiency of the removed TCOD into methane in UASB was as high as 72% and overall TCOD removal efficiency in this system was over 97%. Ammonia nitrogen were stably removed in BNR system and overall efficiency were 98%. With recirculation of the nitrified final effluent to TPAD, nitrogen oxides were completely removed by anaerobic denitrification in the acidogenic reactor, which did not inhibit the acidogenic activities. Overall TN removal efficiency in the TPAD-BNR system was as high as 94%.

Power Factor Correction of the Single Stage AC/DC Converter with Low Conduction Loss and High Efficiency (고효율, 저손실을 갖는 1단 교류/직류 변환기의 역률제어)

  • 류명효;차영길;최병조;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.418-422
    • /
    • 1998
  • A new single stage AC/DC converter based on the forward converter is proposed. The proposed converter offers both the high power factor and the direct conversion from ac line to dc output voltage. Also, the proposed converter reduces the diode conduction loss, so improves the overall efficiency of the converter, compared with other alternatives. The principles of operation and the simulation results of the proposed converter are presented. A 100 W prototype was built and tested to show the potential of applications of the proposed converter.

  • PDF

A Study on Efficient Integrated Kitchen Management of Restaurant (외식업체 통합주방의 효율적인 운영관리에 관한 연구 -통합주방의 중앙공급에 따른 효율화 사례중심으로-)

  • 박종훈;조용범
    • Culinary science and hospitality research
    • /
    • v.9 no.4
    • /
    • pp.54-68
    • /
    • 2003
  • This study aims at efficiency of kitchen management by adoption of a systematic central kitchen and conversion of conventional kitchen to convenience kitchen at ' H ' restaurant. First, integrated menu control of banquet buffet functions became more competitive with quality menu and eventually brought about guests satisfaction. Second, systematic central kitchen made possible standardization and mass production through simplified production line. Efficiency through quick service and shortened preparation time was realized, and food materials were recycled effectively at the same time. Integrated ordering lowered purchasing price and built an efficient cost control system. Third, conversion of conventional kitchen to convenience kitchen and strengthened central kitchen system facilitated agreeable work conditions and optimal work flow with butcher's and even sauce making utensils. Fourth, integrated supply system of buffet menu and sauce from western restaurants saved about 520 million won of labor costs. Last, one integrated kitchen out of two was easier in sanitation control with pleasant restaurant space. Sharing kitchen facilities and equipments also saved about 30% of maintenance fee. Power, water, and gas were also saved and eventually curtailed overall expenses.

  • PDF

Enhancement of Performance of Dye-Sensitized Solar Cell by Reducing the Interface Resistance (계면저항 감소를 통한 염료감응형 태양전지 성능 향상)

  • Kim, Hwi-Dong;Kim, Ki-Hoon;Ahn, Ji-Young;Kim, Soo-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.360-363
    • /
    • 2009
  • In order to improve the overall power conversion efficiency, it is very important to reduce the interface resistance of dye-sensitized solar cells (DSSCs). In this approach, tiny $TiO_2$ nanoparticles with the primary size of 10~20nm were synthesized and deposited between FTO glass and preformed $TiO_2$ layer by $TiOCl_2$ treatment, and also Pt catalysts were deposited on the counter electrode by both ion-sputter and thermal deposition to reduce the electrolyte-counter electrode interface resistance. The influence of these processes on the performace of DSSCs were discussed in terms of fill factor, short circuit current, and conversion efficiency.

  • PDF

Synthesis of Novel Organic Dyes Containing Coumarin Moiety for Solar Cell

  • Choi, Hyun-Bong;Baik, Chul;Kim, Hyun-Jun;Kim, Jeum-Jong;Song, Ki-Hyung;Kang, Sang-Ook;Ko, Jae-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.1973-1979
    • /
    • 2007
  • Novel organic dyes, JK-34, JK-35 and JK-36 containing bis-dimethylfluorenyl amino coumarin unit are designed and synthesized. Nanocrystalline TiO2 dye-sensitized solar cells were fabricated using these dyes. Under standard global AM 1.5 solar condition, the JK-34 sensitized cell gave a short circuit photocurrent density of 10.05 mA cm?2, open circuit voltage of 0.65 V, and a fill factor of 0.68, corresponding to an overall conversion efficiency η of 4.54%. We found that the power conversion efficiency was shown to be quite sensitive to the structural modifications of bridging thiophene moiety.

Analysis of Fourth Harmonic Conversion of High Intensity Nd Laser Beam in KDP Crystal (KDP결정을 이용한 고강도 Nd 레이저광의 제4 고조파변환 해석)

  • 장용무;김병태;강형부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.541-550
    • /
    • 1992
  • The fourth harmonic conversion(FHC) efficiency of high-power Nd laser pulse with wavelength of 1.054x10S0-6Tm using two KDP crystals(doubler adn quadrupler) was simulated numerically. Simulation results show that for the perfect phase-matching condition the FHC efficiency were 60-70% for several hundreds MW/cmS02T class and over 70% for GW/cmS02T class laser pulses. And the overall characteristics of FHC were discussed in terms of effects of input intensity, crystal length, and mismatch angle Δ$\theta$. Optimum method to FHC was type-II doubler & type-I quadrupler KDP crystal because type-II KDP doubler crystal has wide tolerance of acceptance matching-angle.

A High Efficiency Two-stage Inverter for Photovoltaic Grid-connected Generation Systems

  • Liu, Jiang;Cheng, Shanmei;Shen, Anwen
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.200-211
    • /
    • 2017
  • Conventional boost-full-bridge and boost-hybrid-bridge two-stage inverters are widely applied in order to adapt to the wide dc input voltage range of photovoltaic arrays. However, the efficiency of the conventional topology is not fully optimized because additional switching losses are generated in the voltage conversion so that the input voltage rises and then falls. Moreover, the electrolytic capacitors in a dc-link lead to a larger volume combined with increases in both weight and cost. This paper proposes a higher efficiency inverter with time-sharing synchronous modulation. The energy transmission paths, wheeling branches and switching losses for the high-frequency switches are optimized so that the overall efficiency is greatly improved. In this paper, a contrastive analysis of the component losses for the conventional and proposed inverter topologies is carried out in MATLAB. Finally, the high-efficiency under different switching frequencies and different input voltages is verified by a 3 kW prototype.