• Title/Summary/Keyword: over load ratio

Search Result 229, Processing Time 0.033 seconds

Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers (고연성 PET 섬유로 보강된 철근콘크리트 원형 기둥의 내진성능)

  • Vachirapanyakun, Sorrasak;Lim, Myung-Kwan;Choi, Dong-Uk
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.289-298
    • /
    • 2016
  • An experimental research was performed using fibers for the purpose of retrofitting existing reinforced concrete circular columns. Glass fiber (GF) and polyethylene terephthalate (PET) were used as well as combined GF+PET (HF). PET has high tensile strength (over 600 MPa) and high ductility (about 15%), but has very low elastic modulus (about 1/6 of GF). A total of four columns was tested against laterally applied reverse cyclic load: control column, GF-, PET-, and HF-strengthened columns. All columns retrofitted using fibers demonstrated improved moment capacity and ductility. Moment capacity of GF-, PET-, and HF-strengthened columns was 120%, 107%, and 120% of the control column, respectively. Drift ratio of all retrofitted columns also increased by 63 ~ 83% over the control column. The final failure mode of the control column was main bar buckling. The final failure mode of the GF- and HF-strengthened columns was GF rupture while that of the PET-strengthened column was main bar rupture in tension. No damage was observed for PET at the ultimate stage due to excellent strain capacity intrinsic to PET. Current test results indicate that PET can be effectively used for seismic retrofit of RC columns. It is noted that the durability characteristics of PET needs to be investigated in the future.

Pervaporation Characteristics of Water/Ethanol and Water/Isopropyl Alcohol Mixtures through Zeolite 4A Membranes: Activity Coefficient Model and Maxwell Stefan Model (제올라이트 4A 분리막을 이용한 물/에탄올, 물/이소프로필알코올 혼합물의 투과증발 특성 연구 : 활동도계수모형 및 Generalized Maxwell Stefan 모형)

  • Oh, Woong Jin;Jung, Jae-Chil;Lee, Jung Hyun;Yeo, Jeong-gu;Lee, Da Hun;Park, Young Cheol;Kim, Hyunuk;Lee, Dong-Ho;Cho, Churl-Hee;Moon, Jong-Ho
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.239-248
    • /
    • 2018
  • In this study, pervaporation experiments of water, ethanol and IPA (Isopropyl alcohol) single components and water/ethanol, water/IPA mixtures were carried out using zeolite 4A membranes developed by Fine Tech Co. Ltd. Those membranes were fabricated by hydrothermal synthesis (growth in hydrothermal condition) after uniformly dispersing the zeolite seeds on the tubular alumina supports. They have a pore size of about $4{\AA}$ by ion exchange of $Na^+$ to the LTA structure with Si/Al ratio of 1.0, and shows strong hydrophilic property. Physical characteristics of prepared membranes were evaluated by using SEM (surface morphology), porosimetry (macro- or meso- pore analysis), BET (micropore analysis), and load tester (compressive strength). Pervaporation experiments with various temperature and concentration conditions confirmed that the zeolite 4A membrane can selectively separate water from ethanol and IPA. Water/ethanol separation factor was over 3,000 and water/IPA separation factor was over 1,500 (50 : 50 wt%, initial feed concentration). Pervaporation behaviors of single components and binary mixtures were predicted using ACM (activity coefficient model), GMS (generalized Maxwell Stefan) model and DGM (Dusty Gas Model). The adsorption and diffusion coefficients of the zeolite top layer were obtained by parameter estimation using GA (Genetic Algorithm, stochastic optimization method). All the calculations were carried out using MATLAB 2018a version.

GMPLS based Functional Models and Connection Admission Control Algorithms for Optical Burst Switched Networks (광 버스트 교환 망을 위한 GMPLS 기반 기능 모델과 연결 수락 제어 알고리즘)

  • So, Won-Ho;Roh, Sun-Sik;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9B
    • /
    • pp.778-790
    • /
    • 2004
  • In this paper, we propose the functional models of optical burst switching (OBS) routers to apply GMPLS (Generalized Multiprotocol Label Switching) to optical networks based on OBS. In addition, we introduce a connection admission control (CAC) algorithms which are operated in this models and can accommodate the required QoS. Firstly, the characteristics of current GMPLS and OBS for the optical Internet are basically considered. With this consideration, the models are proposed to accept OBS features which include the recognition of data bounda η with control information and the statistical multiplexing in terms of bursts. Secondly, we use an offset time decision (OTD) algorithm on behalf of controlling the connection admission with taking QoS parameters such as burst loss rate(BLR) and service-differentiation ratio(SDR) into consideration. The proposed CAC algorithms use the offered load of LSP (Label Switched Path), wavelength information, and QoS parame ‘ ers as inputs of OTD algorithm. A call setup request will be accepted when the offset time decided by OTD algorithm is reasonable for guaranteeing its requested QoS. Simulation is used for performance evaluation Results show the proposed schemes can guarantee the required QoS and those are better than the previous one in terms of channel utilization.

$CO_2$ Buffering and Hydrogen Ion Concentration Gradient across Cell Membrane in Acute Acid-Base Disturbances in Dogs (혈액과 조직의 $CO_2$완충능 및 세포막을 통한 $H^+$농도 경사)

  • Hwang, Sang-Ik;Park, Young-Bae;Min, Byoung-Ku;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.17 no.2
    • /
    • pp.119-124
    • /
    • 1983
  • The in vivo and in vitro buffer capacities of true plasma and tissue buffer capaciies were compared on dogs. Intracellular pH was determined on skeletal muscle by a modification of the method of Schloerb and Grantham using $C^{14}$ DMO. The in vivo curve for plasma or extracellular fluid has a much lower slope than the in vitro curve. The in vivo slope of skeletal muscle in the dog is approximately 20 sl. The slope for skeletal muscle in vivo falls between the in vitro and in vivo slopes of true plasma. It appears that intracellular hydrogen ion varies linearly with extracellular hydrogen ion when $CO_2$ tension is changed. Both hydrogen ion gradient and Hi/He ratio vary in skeletal muscle, with an increase in $CO_2$ tension. Infusion of 0.3N HCl gave two distinct patterns, the $H_i-H_e$ gradient decreased; and it would appear that very little hydrogen ion as such penetrated to the inside of the cells during the time of observation. Although lactic acid presumably enters the cell and the same of larger load was given as was used for hydrochloric acid, only very mild intracellular acidosis resulted, ostensibly due to metabolism of this substrate. Gluconic acid produced a more severe acidosis, both intracellularly and extracellularly, but with both of these acids the hydrogen ion gradient decreased and the $H_i/H_e$ ratio also decreased. The experiments on the dogs with hemorrhagic shock the hydrogen ion increase producing the acidosis originates inside the cells. Even so, the hydrogen ion gradient increased only very slightly in the acute experiments. This may suggest that even over short intervals of time skeletal muscle cells have a capacity to pump out hydrogen ions at a rate which maintains approximately the normal $H_i/H_e$ gradient when the source of the hydrogen ion is in the interior of the cell.

  • PDF

A study on experiment from the Stair Joints Constructed with PC system part of it using the HI-FORM DECK (HI-FORM DECK를 이용한 부분 PC 계단 접합부의 접합방식에 따른 실험적 연구)

  • Chang, Kug-Kwan;Lee, Eun-Jin;Jin, Byung-Chang;Kang, Woo-Joo;Han, Tae-Kyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.9-12
    • /
    • 2008
  • The semi-rigid joint is the shape of middle that can supplement the defect of pin joints and accept the good point of rigid joints. Recently, a study on the pin joints is activated in the country, but because the study on semi-rigid joints is not many, this study tried to prove with producing test model of three shape. The test models are rigid joint HI-R, semi-rigid joint HI-S, pin joint HI-P. As a result of the test, respectively HI-R, HI-S, HI-P appeared shear failure of joint, flexure failure of the top fixing, flexure failure of the lower part slipping stair slab, and the maximum strength is measured to 51.74, 51.4, 24.63kN, the stiffness is appeared 1.58, 1.19, 0.37 respectively, The yield strength is respectively kept 44.5, 47.3, 24kN, and ductility ratio is appeared to 3.31, 2.32, 1.54, when is based on KBC code, sag of the acting service load is appeared that HI-P model is over the standard. When is based on distribution of bars strain ratio, HI-S seems similar behavior incipiently, but after the yield, the semi-rigid joint was able to be judged better than pin joint because of the stress allotment of joint internal elements.

  • PDF

Temporal and Spatial Analysis of Non-biodegradable Organic Pollutants in the Geumho River System (금호강 수계 난분해성 유기오염물질에 대한 시·공간적 특성 분석)

  • Jung, Kang-Young;Ahn, Jung-Min;Lee, Kyung-Lak;Lee, In-Jung;Yu, Jae-Jeong;Cheon, Se-Uk;Kim, Kyo-Sik;Han, Kun-Yeun
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1343-1362
    • /
    • 2015
  • As a result of analysis based on the observed data for BOD, COD and TOC in order to manage non-biodegradable organics in the Geumho River, COD/BOD ratio was analyzed as the occupying predominance proportion. In this study, the classification(changes in water quality measurement : increase, equal, decrease) and measurement of BOD and COD were analyzed for trends over the past 10 years from 2005 to 2014 in the Geumho River. The Geumho River is expected to need non-biodegradable organics management because BOD was found to be reduced 61.1% and COD was found to be increased 50%. As a result of the analysis of land use, the Geumho-A is a unit watershed area of $921.13km^2$, which is the most common area that is occupied by forests. The Geumho-B is a unit watershed area of $436.8km^2$, which is the area that is highest occupied by agriculture and grass of 24.84%. The Geumho-C is a unit watershed area of $704.56km^2$ accounted for 40.29% of the entire watershed, which is the area that is occupied by urban of 15.12%. Load of non-biodegradable organics, which is not easy biodegradable according to the discharge, appeared to be increased because flow coefficient of COD and TOC at the Geumho-B were estimated larger than 1 value. The management of non-point sources of agricultural land is required because the Geumho-B watershed area occupied by the high proportion of agriculture and field. In this segment it showed to increase the organics that biodegradation is difficult because the ratio of BOD and TOC was decreased rapidly from GR7 to GR8. Thus, countermeasures will be required for this.

A selective sparse coding based fast super-resolution method for a side-scan sonar image (선택적 sparse coding 기반 측면주사 소나 영상의 고속 초해상도 복원 알고리즘)

  • Park, Jaihyun;Yang, Cheoljong;Ku, Bonwha;Lee, Seungho;Kim, Seongil;Ko, Hanseok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.12-20
    • /
    • 2018
  • Efforts have been made to reconstruct low-resolution underwater images to high-resolution ones by using the image SR (Super-Resolution) method, all to improve efficiency when acquiring side-scan sonar images. As side-scan sonar images are similar with the optical images with respect to exploiting 2-dimensional signals, conventional image restoration methods for optical images can be considered as a solution. One of the most typical super-resolution methods for optical image is a sparse coding and there are studies for verifying applicability of sparse coding method for underwater images by analyzing sparsity of underwater images. Sparse coding is a method that obtains recovered signal from input signal by linear combination of dictionary and sparse coefficients. However, it requires huge computational load to accurately estimate sparse coefficients. In this study, a sparse coding based underwater image super-resolution method is applied while a selective reconstruction method for object region is suggested to reduce the processing time. For this method, this paper proposes an edge detection and object and non object region classification method for underwater images and combine it with sparse coding based image super-resolution method. Effectiveness of the proposed method is verified by reducing the processing time for image reconstruction over 32 % while preserving same level of PSNR (Peak Signal-to-Noise Ratio) compared with conventional method.

Job Characteristics of the Fashion Designers of Women's Wear Industries in Taegu (대구(大邱) 여성복(女性服) 생산업체(生産業體) 디자이너들의 직무실태(職務實態))

  • Kim, Soon-Boon
    • Journal of Fashion Business
    • /
    • v.3 no.4
    • /
    • pp.83-91
    • /
    • 1999
  • The purpose of this study is to provide some useful references to the educational field in terms of providing on analysis of job characteristics of fashion designers working in the women's wear industries. The data were collected from 102 fashion designers working in women's wear industries through the questionnaire and were analyzed by SPSS packages of frequencies and percentiles for comparative study, and the results are as follows: 1. The demographic characteristics of the fashion designers are; unmarried (80.4%), working less than 2 years (20.2%), completion of junior college(68.6%), majority ages between 20-24 yrs(43.1%). An average length of working in one company war less than 6 months. 2. The ratio computer usage of the design room was approx. 52.0% especially in the management of sales (52.9%) and the ratio in fashion design was approx. 17.6% in merchandising planning. 3. 76.4% of respondents was working 10 hours a day, and 50% of them was dissatisfied on the job caused by excessive working hour (31.4%) and job over load (35.3%). In the developing fashion design with the relation of actual job, insufficient knowledges of the concerned technical and production fields (68.6%) were indicated as the most difficult area. In addition, fashion magazines were considered as the most helpful resource(94.1%). 4. It was noted that the target age groups for the brand were clearly divided into two groups, notably the early and middle of twenties and the early and middle forties. Among the produced items, formal wears were accounted for 52.9%. 5. As far as the contents of job are concerned, the fashion designers are mostly engaged in purchasing textile, collecting informations of fashion, quality control, whereas their actual job is apparel design. 6. The training that the fashion designer received beside formal education includes attendance of private institutes(62.7%), OJT(7.8%), seminars(4.9%). Regarding formal education, the respond indicated that they had least opportunity to received computer training. 7. The necessary subjects in the schools for the fashion designers in relation to the current job were fashion information, merchandising planning, pattern making, cutting, fashion marketing, knowledges of clothing material in sequence. Subjects which are necessary for the further development include pattern making(21.6%), fashion marketing(14.7%), and designing with computer(7.8%).

  • PDF

Seismic Performance and Retrofit of Reinforced Concrete Two-Column Piers Subjected to Bi-directional Cyclic Loadings (이축반복하중을 받는 2주형 철근콘크리트 교각의 내진성능과 보강)

  • Chung, Young-Soo;Park, Chang-Kyu;Lee, Ho-Yul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.47-55
    • /
    • 2006
  • Seismic performance and retrofit of reinforced concrete (RC) two-column piers widely used at roadway bridges in Korea was experimentally evaluated. Ten two-column piers that were 400 mm in diameter and 2,000 mm in height were constructed. These piers were subjected to hi-directional cyclic loadings under a constant axial load of $0.1f_{ck}A_g$. Test parameters were the confinement steel ratio, loading pattern, lap splice of longitudinal reinforcing bars, and retrofitting method. Specimens with lap-spliced longitudinal bars were retrofitted with steel jacket, pre-stressing steel wire, and steel band. Test result showed that while the specimens subjected to bi-directional lateral cyclic loadings which consisted of two main amplitudes in the transverse axis and two sub amplitudes in longitudinal axis, referred to as a T-series cyclic loadings, exhibited plastic hinges both at the top and bottom parts of the column, the specimens subjected to bi-directional lateral cyclic loadings in an opposite way, referred to as a L-series cyclic loadings, exhibited a plastic hinge only at the bottom of the column. The displacement ductility of the specimen under the T-series loadings was bigger than that of the specimen under the L-series loadings. Specimen retrofitted with pre-stressing steel wires exhibited poor ductility due to the upward shift of the plastic hinge region because of over-reinforcement, but specimens retrofitted with steel jacket and steel band showed the required displacement ductility. Steel band can be an effective retrofitting scheme to improve the seimsic performance of RC bridge piers, considering its practical construction.

A Study for the Adaptation of Simulation of Uniaxial Compressive Strength Test for Concrete in 3-Dimensional Particle Bonded Model (3차원 입자 결합 모델에서 콘크리트의 일축압축실험 모사 적용성 연구)

  • Lee, Hee-Kwang;Jeon, Seok-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.147-156
    • /
    • 2008
  • In an uniaxial compressive test of a concrete standard specimen (150$\times$300 mm) the crack initiation and extension with the stress increase are the major reason of the failure, which is similar to the breakage of the particle bonding in the simulation by using particle bonded model, especially particle flow code in 3 dimensions (PFC3D) developed by Itasca Consulting Group Inc. That is the main motive to study the possibility of an uniaxial compressive strength test simulation. It is important to investigate the relationship between the micro-parameters and the macro-properties because the 3-dimensional particle bonded model uses the spherical particles to analyze the physical phenomena. Contact bonded model used herein has eight micro-parameters and there are five macro-properties; Young's modulus, Poisson's ratio, uniaxial compressive strength and the crack initiation stress and the ratio concerning the crack propagation with the stress. To simulate the compressive test we made quantitative relationships between the micro-parameters and the macro-properties by using the fractional factorial design and various sensitivity analyses including regression analysis, which result in the good agreement with the previous studies. Also, the stress-stain curve and the crack distribution over the specimen given by PFC3D showed the mechanical behavior of the concrete standard specimen under the uniaxial compression. It is concluded that the particle bonded model can be a good tool for the analyzing the mechanical behavior of concrete under the uniaxial compressive load.