• Title/Summary/Keyword: over load

Search Result 2,154, Processing Time 0.026 seconds

A Study on DC Circuit Breaker using SCR Chung Hoo Park (SCR 에 의한 직류회로차단기의 과부하차단특성개선)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF

A Study on the Economical Feasibility Analysis For Development of Dual Mode Trailer System

  • Kim, Kwang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • In light of the growing traffic congestion problem and congestion cost, the container transport by railway has to be increased. The freight transport by railway can have decided advantages over trucks in terms of energy efficiency, emissions and cost for certain freight movements, just as transportation in the metropolitan region can have great advantages over driving truck. But the freight transport by truck should gain significant mobility benefits from a freight railway system. Thus, the DMT(Dual Mode Trailer) transport system which is coupled railway transport advantages with load transport advantages has been developed and used in the european countries. The DMT transport will therefore serve the areas required by transport organizers. The purpose of this paper is to estimate economical feasibility analysis for development of DMT transport system. Consequently, this study analyzed the characteristics of the DMT system. The horizontal load.unload system is being considered as an adoptable DMT system in consideration of the situation in Korea.

Development of energy saving type life testing device for large machinery parts (에너지절감형 대형기계류부품용 수명시험장치의 개발)

  • Lee, Yong Bum;Shin, Suk Shin;Park, Jong Ho
    • Journal of Applied Reliability
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • For a reliability assessment of large machinery parts, reliable data should be obtained from testing many samples for a long time. However, in case of testing these samples, testing cost is excessive; in case of life test for long time, power consumption is high; and in case of accelerated test by over load, very high cost is required to build the life testing device. Especially it is very frequent that the expensive device's life has ended during a accelerated test by over load. In this study, the design mechanism of the life testing device which excels in energy saving during the reliability test of large machinery parts has been introduced.

Buckling and vibration analysis of stiffened plate subjected to in-plane concentrated load

  • Srivastava, A.K.L.;Datta, P.K.;Sheikh, A.H.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.6
    • /
    • pp.685-704
    • /
    • 2003
  • The buckling and vibration characteristics of stiffened plates subjected to in-plane concentrated edge loading are studied using finite element method. The problem involves the effects of non-uniform stress distribution over the plate. Buckling loads and vibration frequencies are determined for different plate aspect ratios, boundary edge conditions and load positions. The non-uniform stresses may also be caused due to the supports on the edges. The analysis presented determines the initial stresses all over the region considering the pre-buckling stress state for different kinds of loading and edge conditions. In the structural modeling, the plate and the stiffeners are treated as separate elements where the compatibility between these two types of elements is maintained. The vibration characteristics are discussed and the results are compared with those available in the literature and some interesting new results are obtained.

SOC-based Sequencing Equalizer for Parallel-connected Battery Configuration using ANFIS Algorithm

  • Duong, Tan-Quoc;La, Phuong-Ha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.174-175
    • /
    • 2019
  • Battery cells are connected in parallel to enlarge the system capacity. However, cell inconsistency may reduce the overall system capacity and cause the over-charging or over-discharging issue. This paper proposes a SOC-based sequencing equalizer for parallel-connected battery configuration that uses the ANFIS (adaptive neuro-fuzzy inference system) algorithm to make the switching decision. Depend on the load current and the SOC (state-of-charge) rate of cells, the switching decision is made to equalize the SOC of the battery cells. The simulation results show that the system capacity is maximized and the controller is adaptive for a large number of parallel-connected in dynamic load profile.

  • PDF

A study on high-voltage measuring system using bushing-type capacitor (부싱형 커패시터를 이용한 고전압 계측시스템에 관한 연구)

  • Gang, Mun-Seong;Sim, Hyeong-Gwan;Yu, Chung-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.502-507
    • /
    • 1999
  • An improved, accurate and reliable high-voltage measuring system utilizing a bushing-type capacitor is proposed in this study. This system measures voltages and phase angles of three-phase 22.9 kV power distribution lines and provides enough current to charge a battery for a motor-driven load switch and to operate the measuring and communication circuits for the distribution automation. For reliability, epoxy resin was used as the dielectric material of the bushing-type capacitor since the dielectric strength of epoxy resin is very stable over the wide range of temperature. Capacitances were investigated and found to be stable over the wide range of temperature and applied voltage, and the results indicate that the proposed measurement system is very reliable.

  • PDF

Applications of the Light Weight Method of EPS to Sub-road Fills at the Seaside (해안 도로상의 EPS 하중경감공법의 해석)

  • 장용채
    • Journal of Korean Port Research
    • /
    • v.14 no.2
    • /
    • pp.233-239
    • /
    • 2000
  • The expansion of old road is needed in constructing the entrance at the $\bigcirc$$\bigcirc$I/C road in $\bigcirc$$\bigcirc$city. To strength the national competition, many agents who concerned do their best for finishing that construction early as soon as possible. In generally, soil embankment on soft foundation is caused to reduce the stability by making the settlement of ground surface due to the over load. Thus, we try to make it stable by building EPS embankment construction which in our working place is one kind of the method of light embankment construction after excavating the original ground.

  • PDF

Applications of the EPS Embankment Metod to Earth Fils at the Seaside (해안 매립지역의 EPS 성토공법 적용)

  • 장용채;조성민;이유옥
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.219-224
    • /
    • 1999
  • The expansion of old road is needed in construction the entrance at the $\bigcirc$$\bigcirc$I/C road in $\bigcirc$$\bigcirc$city. To strength the national competition, many agents who concerned do their best for finishing that construction early as soon as possible. In generally, soil embankment on soft foundation is caused to reduce the stability by making the settlement of ground surface due to the over load. Thus, we try to make it stable by building EPS embankment construction which in our working place is one kind of the method of light embankment construction after excavating the original ground.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

Change of Strength of High-Strength Bolted Connection Depending on Standard and Over Bolt Hole (표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화)

  • Yang, Seung-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.605-612
    • /
    • 2012
  • A tension member that has a high-strength bolt fastened to a standard bolt hole increases structural resistance but causes problems from workability or economic perspectives. In this research, a total of 28 samples that have standard and over bolt holes as the tension member's high-strength bolted connection were made and a tension test was conducted. The change of strength of the connection has been confirmed by comparing the tension load of standard and over bolt hole samples obtained from the test results with the design strength due to net section and end distance. Samples made with over bolt holes had a lighter tension load than that of samples made with standard bolt holes, exceeded the design strength of present design standards, and although decrease in strength was inevitable due to the over bolt hole, their safety was satisfactory.