• Title/Summary/Keyword: over current characteristics

Search Result 1,158, Processing Time 0.035 seconds

A Random Forest Model Based Pollution Severity Classification Scheme of High Voltage Transmission Line Insulators

  • Kannan, K.;Shivakumar, R.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.951-960
    • /
    • 2016
  • Tower insulators in electric power transmission network play a crucial role in preserving the reliability of the system. Electrical utilities frequently face the problem of flashover of insulators due to pollution deposition on their surface. Several research works based on leakage current (LC) measurement has been already carried out in developing diagnostic techniques for these insulators. Since the LC signal is highly intermittent in nature, estimation of pollution severity based on LC signal measurement over a short period of time will not produce accurate results. Reports on the measurement and analysis of LC signals over a long period of time is scanty. This paper attempts to use Random Forest (RF) classifier, which produces accurate results on large data bases, to analyze the pollution severity of high voltage tower insulators. Leakage current characteristics over a long period of time were measured in the laboratory on porcelain insulator. Pollution experiments were conducted at 11 kV AC voltage. Time domain analysis and wavelet transform technique were used to extract both basic features and histogram features of the LC signal. RF model was trained and tested with a variety of LC signals measured over a lengthy period of time and it is noticed that the proposed RF model based pollution severity classifier is efficient and will be helpful to electrical utilities for real time implementation.

Maximum Torque Control of Induction Motor using Adaptive Learning Neuro Fuzzy Controller (적응학습 뉴로 퍼지제어기를 이용한 유도전동기의 최대 토크 제어)

  • Ko, Jae-Sub;Choi, Jung-Sik;Kim, Do-Yeon;Jung, Byung-Jin;Kang, Sung-Joon;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.778_779
    • /
    • 2009
  • The maximum output torque developed by the machine is dependent on the allowable current rating and maximum voltage that the inverter can supply to the machine. Therefore, to use the inverter capacity fully, it is desirable to use the control scheme considering the voltage and current limit condition, which can yield the maximum torque per ampere over the entire speed range. The paper is proposed maximum torque control of induction motor drive using adaptive learning neuro fuzzy controller and artificial neural network(ANN). The control method is applicable over the entire speed range and considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d, q axis current $_i_{ds}$, $i_{qs}$ for maximum torque operation is derived. The proposed control algorithm is applied to induction motor drive system controlled adaptive learning neuro fuzzy controller and ANN controller, the operating characteristics controlled by maximum torque control are examined in detail. Also, this paper is proposed the analysis results to verify the effectiveness of the adaptive learning neuro fuzzy controller and ANN controller.

  • PDF

A Study of Suppression Current for LDMOS under Variation of Temperature (온도변화에 따른 LDMOS의 전류변동 억제에 관한 연구)

  • Jeon, Joong-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.8
    • /
    • pp.901-906
    • /
    • 2006
  • In this paper, the power amplifier using active bias circuits for LDMOS(Lateral Diffused Metal Oxide Semiconductor) MRF-21180 is designed and fabricated. According to change the temperature, the gate voltage of LDMOS is controlled by the fabricated active bias circuits which is made of PNP transistor to suppress drain current. The driving amplifier using MRF-21125 and MRF-21060 is made to drive the LDMOS MRF-21180 power amplifier. The variation of current consumption in the fabricated 60 watt power amplifier has an excellent characteristics of less than 0.1 A, whereas a passive biasing circuit dissipates more than 0.5 A. The implemented power amplifier has the gain over 9 dB, the gain flatness of less than $\pm$0.1 dB and input and output return loss of less than -6 dB over the frequency range 2.11 $\sim$ 2.17 GHz. The DC operation point of this power amplifier at temperature variation 0 $^{\circ}C$ to 60 $^{\circ}C$ is fixed by active bias circuit.

Effect of Delay Time Control on the Spatter Generation in $CO_2$ Welding ($CO_2$ 용접에서 스패터 발생에 미치는 지연시간 제어의 영향)

  • 이창한;김희진;강봉용
    • Journal of Welding and Joining
    • /
    • v.17 no.5
    • /
    • pp.61-68
    • /
    • 1999
  • For the last two decades, waveform control techniques have been successively developed and applied for the inverter welding machines resulting in the substantial reduction of spatter generated in CO₂ welding. One of the constituents commonly involved in those techniques is to delay the instant of current increase to some extent after the initiation of short-circuiting. Although this technique has been known to be quite effective in reducing the spatter generation through the suppression of is instantaneous short circuiting, the delay time necessary for minimum spatter has not been clearly understood. In this study, the control system for varying the delay time was constructed so that the spatter generation rates could be measured over a wide range of delay time, 0.29-2.0 msec. As a result of this study, it was demonstrated that spatter generation rate(SGR) sharply decreased at delay time of 0.6 msec and longer accompanied with the change in characteristics of short circuit mode from the instantaneous short-circuiting(ISC) dominant to normal short-circuiting(NSC) dominant. Another feature that have been found in current waveform of over 0.6msec was the creation of current pulse right after the arc reignition stage. Because of this current pulses weld pool oscillated in wave-like fashion and it looks like to play an important role in developing short circuiting between electrode and weld pool.

  • PDF

A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires (전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구)

  • Hwang, Jin-Kwon
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Several electrical loads such as inrush current, normal operation arcing and non-sinusoidal loads have normal current waveforms similar to arc waveforms. To detect arcs in such loads, therefore, it is necessary to analyze difference between current waveforms with or without arcs. In this paper, using apparatuses of arc generation in UL 1699, arcs are generated in these loads and, then, arc current waveforms are investigated in both the time and the frequency domains to find arc characteristics. This investigation shows that arc current signals have shoulders at some zero current points in the time domain and increment of spectrum magnitude in all over frequency domain. It also shows that the arc characteristics at normal operation arcing and non-sinusoidal loads are detected more easily in the frequency domain than in the time domain. This investigated arc characteristics are expected to be utilized as the basis of development of arc-fault circuit interrupters.

The Electrical Characteristics of Shading Effect in Photovoltaic Module (PV모듈에서 그림자에 의한 전기적 특성)

  • Kim, Seung-Tae;Kang, Gi-Hwan;Park, Ji-Hong;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.257-262
    • /
    • 2008
  • In this paper, we study the electric characteristics of shading effects in photovoltaic module in case of outdoor operation. When fabricating PV module, solar cells are connected serially to obtain the high voltage because of its low open circuit voltage. And total current is determined by lowest current among solar cells. When the shading happens on PV module's surface, the current of shaded solar cell determine the total current flow. Because of this, generally by-pass diode is installed on junction box. The bypass diode operate when revered and shaded solar cell's voltage is over 0.6 voltage. The reverse-biased solar cell gives reduced maximum power of PV module and might give negative effect on durability. So, adequate by-pass installation and selection is needed.

  • PDF

Relevance Analysis of Performance Evaluation Systems of Government S&T Research Groups (출연연구기관의 연구회 단위 기관평가제도의 적합성 분석)

  • Nam, Yeong-Ho;Kim, Byeong-Tae
    • Journal of Technology Innovation
    • /
    • v.14 no.3
    • /
    • pp.117-154
    • /
    • 2006
  • This research examines performance evaluatees' opinions regarding the current institutional performance evaluation systems of Government S&T Research Institutes (GRIs). Under the current evaluation systems, twenty GRIs are grouped into three Research Groups and each Group has its own evaluation systems. One problem of the current institutional evaluation systems is that the systems cannot reflect individual GRIs' characteristics. The following methods are used. First, based on four perspectives of Kaplan & Norton(1992)'s Balanced Scorecard(BSC) model, six perspectives appropriate to GRUs' characteristics are derived. Second, experts classify current performance evaluation measures into the six perspectives. This enables different evaluation systems of three GRI Research Groups to be compared under the same evaluation measures. Third, GRIs' evaluatees are asked to allocate appropriate weights on the performance measures. Evaluatees' weights of a GRI are compared with average weights of the related Group. Finally in every BSC's perspective, GRIs that have extraordinarily over-scored or under-scored weights are analyzed in terms of GRIs' missions, customers, capability of human resources, etc. In the Basic Research Group, the Korea Basic Science Institute is deviated in the financial perspective and the strategic direction perspectives. In the Public Research Group, Korea Institute of Construction Technology is significantly different from other GRIs in three perspectives. Five out of eight GRIs in the Industrial Research Group, GRIs are significantly different each other in several perspectives. It could be concluded that the current institutional evaluation systems are least appropriate in measuring performance of the GRIs of the Industrial Research Group.

  • PDF

Comparison of Fault Current Limiting Characteristics According to Facility in Power System (전력계통의 사고전류 저감 설비별 특성 비교)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System (휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계)

  • Kang, Chang-Yong;Kim, Eun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

A clinical study of ADL and health related Behaviors of elders Aged 65 or over in An urban Area (도시지역 노인의 ADL과 건강관리에 대한 임상적 연구)

  • Hur, Young-Gu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.4 no.1
    • /
    • pp.45-58
    • /
    • 1998
  • This study was carried out to find out general characteristics and health-related behaviors of elders aged 65 or over and factors related to their activities of daily living. and thus to contribute to their health maintenance and promotion. The subjects were 200 elders who had resided at Tae Jean city, with males and females was scaled 1 : 3. To collect data for study, the field survey was conducted from March 20 to October 31, 1997 with questionaire. 1. 65.0% of the subjects were 65-75 years old, while 35.0% were 75 years old or over, 20.5% of them were illterate, 46.5% could read and write Korean. graduated from elementary school, and 11.5% middle school or higher level. 2. 28.5% of subjects perceived their current health status, 46.0% of men and 38.0% of women as fair, In genal elderly men perceived their health status better than elderly women. Among the subjects, 62.0% of men and 57.0% of women reported that they experienced one or more illnesses during the last year. 3. 76.0% of men and 33.0% of women were current smokers. 55.0% of current smokers. 55.0% of current make smokers smoked 11-12 cigarettes per day and 53.2% of current female smokers smoked less than 10 cigarettes per day. 4. 76.0% of men and 37.3% of women drank alchol currently. 5. 56.0% of men and 34.7% of women practiced regular exercise for their health maintenance and promotion. 6. In general, 38.5% of subjects needed other's assistance for doing one or more Activites such as doing heavy home work, Walking up and down stairs or walking half a mile. 7. Common disease of the subjects were hypertention, depenerative arthritis and diabetes mellitus in order.

  • PDF