• Title/Summary/Keyword: outdoor temperature

검색결과 797건 처리시간 0.022초

표면방전의 집중에 따른 옥외용 설비의 성능평가 (The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge)

  • 임장섭;정승천;이진;노진양
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

트레일 러닝을 위한 아웃도어 웨어 디자인 개발 (Design Development of Outdoor Wear for Trail Running)

  • 김윤
    • 복식
    • /
    • 제65권3호
    • /
    • pp.151-166
    • /
    • 2015
  • This research aims to study the needs of the trail runners as trail running has become a popular outdoor activity, and give suggestions for high functional outdoor menswear design that can satisfy the needs of the highly demanding taste of runners. The design development is as follows: 1) The design had to be made of lightweight material and be easily packable in all situations, and 2) we also considered the ergonomic and compact fit for activity, 3) the functional location of high functional fabric, 4) the reflective use and layering system giving a wide range of outdoor workout time and 5) the trend in 2016 S/S active sports and outdoor wear. Based on the above elements, the men's outdoor wear design has been developed for trail running in spring and summer. The design development includes a total of 7 items. The design focused on lightweight, availability of packaging, "comfortability" and freshness in activity, functional suitability of location of highly functional materials and the layering system to protect body temperature under the changing environment. In particular, the layering system was implemented to provide ventilation, and it was done in body parts that released the most body heat. Therefore, mesh materials were actively used on the side panel, sleeves and center of the back piece for necessary sweat emission without any problems and ventilation for trail running.

면역 시스템을 이용한 에어콘의 온도 제어 시스템 설계 ((On designing Temperature Control System of the Air-conditioner using immune system))

  • 서재용;조현찬;전홍태
    • 전자공학회논문지SC
    • /
    • 제39권1호
    • /
    • pp.1-6
    • /
    • 2002
  • 본 논문에서는 제한된 센서를 이용한 에어콘의 온도제어용 실내 ·외 온도 추론 시스템을 제안하였다. 제안한 온도추론 시스템은 자연계의 면역 시스템의 네트워크 이론을 이용한 실내온도 추론과정과 실외온도 추론과정으로 구성되어 있으며, 실시간 온도추론이 가능하도록 설계하였다. 면역기법을 이용한 온도 추론 시스템은 과거의 정보를 효과적으로 이용함으로써 주어진 입력 데이터뿐만 아니라 학습되지 않는 데이터에 대해서도 온도 추론능력이 우수하다.

PWM 스크롤압축기를 적용한 시스템 에어컨의 냉방운전 시 압축기 토출온도에 대한 상관식 개발 (Correlation on Compressor Discharge Temperature of System A/C Applying PWM Scroll Compressor in Cooling Mode)

  • 권영철;박삼진;고국원;박병권;김대훈;윤백
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.154-159
    • /
    • 2006
  • 본 연구는 PWM 방식의 스크롤 압축기를 적용한 에어컨 시스템의 압축기 운전주기, 실내 온도, 그리고 실외온도를 변화시키면서 시스템 에어컨의 최적효율을 나타내는 압축기 토출온도 상관식을 도출하고자 실험연구를 수행하였다. 실험은 실내 및 실외 온도변화에 따른 시스템의 성능 및 압축기 토출온도를 측정 하고자 다양한 온도를 설정하였다. 압축기 토출온도는 로딩듀티와 실외온도가 증가함에 따라 선형적으로 증가하였다. 로딩듀티(loading duty)와 실외온도 변화에 따른 압축기 토출온도는 실내온도 변화보다 실외온도의 변화에 더 크게 변화하였다. 압축기 토출온도 상관식은 실외온도, 실내온도, 그리고 로딩듀티의 함수로 표현되었으며, 실험으로부터 획득된 압축기 토출온도와 최대 $3^{\circ}C$ 이내에서 만족함을 확인하였다.

중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구 (Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System)

  • 황진원;안병천
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6759-6765
    • /
    • 2015
  • 본 연구에서는 자연외기를 활용하여 건물의 중앙냉방시스템에 대한 에너지를 절약하기 위한 제어방법으로서 외기온도 조건을 고려한 나이트 퍼지제어의 적용방안에 대해 시뮬레이션 연구가 수행되었다. 외기온도의 변화특성 및 건물의 축냉성능 등이 고려되었으며, 나이트 퍼지제어를 위한 운전시작시간과 제어설정온도의 선정방안이 연구되었다. 본 연구를 위하여 TRNSYS 프로그램을 활용하여 시스템 해석 모델링을 수행하였으며, 기존 제어방식 대비 제안된 제어방법의 에너지 절약성능을 비교 분석하였다. 연구결과로 외기온도 변화에 따라 나이트 퍼지제어를 위한 운전조건을 선정한 제안된 제어방법이 기존의 나이트 퍼지제어 제어방식과 비교하였을 때는 최대 16.8%, 나이트 퍼지제어를 적용하지 않은 경우에 비해서는 최대 28.6%의 에너지 절감이 가능함을 알 수 있었다.

저온에서 흡착제의 제습효과에 대한 연구 (A Study on the Dehumidification effect of Adsorbent at low Temperature)

  • 이민석;정윤호;임소민;허재우;김종열
    • 융합신호처리학회논문지
    • /
    • 제21권4호
    • /
    • pp.177-182
    • /
    • 2020
  • 친환경적이고 에너지 절약적인 난방 방법으로 히트펌프에 대한 관심이 높아지고 있다. 특히, 저온 지역에서 난방이 가능한 히트펌프를 개발하기 위해 실외기 표면에 서리가 발생하지 않도록 하는 연구가 많아지고 있다. 즉, 온도가 낮은 지역에서 히트펌프를 통해 난방을 할 경우 실외기 표면에 서리층이 형성되어 전열성능을 떨어뜨려 난방능력을 감소시키는 것이 일반적이다. 따라서 본 연구에서는 히트펌프의 실외기에 유입되는 습공기의 수증기를 흡착식 제습시스템을 부착하여 제거하고자 한다. 본 연구를 통해 저온지역에서 가장 효과적인 제습방법을 제시할 수 있을 것으로 판단된다. 그리고 히트펌프의 실외기 전면에 흡착식 제습시스템을 부착하여 에너지 효율이 높은 히트펌프를 개발할 수 있을 것으로 사료된다.

재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석 (Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

온실의 냉난방부하 산정을 위한 외부기상자료 비교분석 (Comparative Analysis of Weather Data for Heating and Cooling Load Calculation in Greenhouse Environmental Design)

  • 남상운;신현호;서동욱
    • 생물환경조절학회지
    • /
    • 제23권3호
    • /
    • pp.174-180
    • /
    • 2014
  • Standard weather data available to greenhouse environmental design are limited in most regions of the country. So, instead of using standard weather data, in order to find the method to build design weather data for greenhouse heating and cooling, design outdoor weather conditions were analyzed and compared by TAC method and frequency analysis using climatological normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average TAC values of outdoor temperature, relative humidity and insolation using thirty years hourly weather data showed a good agreement with them using standard weather data. Therefore, in regions which are not available standard weather data, we suggest that design outdoor weather conditions should be analyzed using thirty years hourly weather data. Average of TAC values derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data.

해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 - (A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park -)

  • 조원석;김흥기
    • 한국농촌건축학회논문집
    • /
    • 제10권3호
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

유한 요소 해석 프로그램을 이용한 모듈 내 온도 분포 예측 (Prediction of temperature distribution in PV module using finite element method)

  • 박영은;정태희;고석환;주영철;김준태;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.65-72
    • /
    • 2016
  • PV module is installed in various outdoor conditions such as solar irradiation, ambient temperature, wind speed and etc. Increase in solar cell temperature within PV module aggravates the behaviour and durability of PV module. It is difficult to measure temperature among respective PV module components during PV module operating, because the temperature within PV module depends on thermal characteristics of PV module components materials as well as operating conditions such as irradiation, outdoor temperature, wind etc. In this paper, simulation by using finite element method is conducted to predict the temperature of each components within PV module installed to outdoor circumstance. PV module structure based on conventional crystalline Si module is designed and the measured values of thickness and thermal parameters of component materials are used. The validation of simulation model is confirmed by comparing the calculated results with the measured temperatures data of PV module. The simulation model is also applied to estimate the thermal radiation of PV module by front glass and back sheet.