• Title/Summary/Keyword: outdoor air quality

Search Result 207, Processing Time 0.022 seconds

Variation of Formaldehyde Concentration in Preschool Facilities by Location and Indoor/Outdoor (유아교육시설의 위치 및 실내${\cdot}$실외에 따른 포름알데히드 농도 변화)

  • Yoon , Chung-Sik;Jeong , Jee-Yeon;Yi , Gwang-Yong;Park , Dong-Uk;Park , Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.259-263
    • /
    • 2004
  • This study was performed to investigate airborne formaldehyde concentration in preschool facilities. Arithmetic mean of indoor formaldehyde concentration in urban area was 34.9 ppb(Geometric mean 24.4 ppb) whereas outdoor concentration was 21.5 ppb(GM 11.9 ppb). In rural area, formaldehyde concentrations were 36.4 ppb(GM 28.7 ppb), 4.1 ppb(GM 4.1 ppb), respectively. There is no statistical significance between the formaldehyde concentrations of urban classrooms and those of rural area. We verified that the distribution of airborne formaldehyde concentration was log-normal characteristic using Shapiro and Wilk test. The 6.7% of urban indoor samples was exceeded the domestic standard limit of indoor air quality. From our study and other study, we concluded that the major emission sources of formaldehyde in preschool facilities was in indoor rather than outdoor.

A study on the effect on indoor air quality by ventilation system operation in buses (고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화)

  • An, Sun-Min;Lee, Jung-Sub;Shim, In-Keun;Kim, Ho-Hyun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

Physical Properties of Magnesium Oxide-Based Adsorption Matrix using Diatomite (산화마그네슘 기반 규조토를 활용한 흡착형 경화체의 물리적 특성)

  • Lee, Won-Gyu;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.184-185
    • /
    • 2019
  • Korea has defined fine dust as a social disaster as the problem of fine dust and air pollution becomes serious. Fine dust is classified as class one carcinogens because it is harmful to human body. When fine dusts enter the human body, they cause bronchial and skin diseases such as respiratory allergies, irritable pneumonia, asthma and atopy. As the air pollution becomes serious, the government is demanding measures to reduce fine dust. The polluted air in the outdoor is introduced into the room, thereby increasing the pollution degree of the indoor air quality. In this study, an adsorption type matrix for the improvement of indoor air quality was produced. Magnesium oxide and magnesium chloride were used as binders and diatomaceous earth was used as a adsorption material.

  • PDF

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

Characterization of Indoor Air Quality Using multiple Measurements of Nitrogen Dioxide and Volatile Organic Compounds

  • Son, Bu-Soon;Yang, Won-Ho;Sohn, Jong-Ryeal;Kim, Dae-Won;Jung, Soon-Won;Kim, Young-Hee
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.293-298
    • /
    • 2005
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Indoor and outdoor NO$_2$ and VOCs(benzene, toluene, xylene) concentrations were measured every 3 days for 60 consecutive days in 30 houses in Seoul, Asan and Daegu, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, NO$_2$ and VOCs source strengths (ppb/hr) and deposition constant (K, hr$^{-1}$) were estimated. Deposition constants of NO$_2$, toluene and xylene were 0.98 ${\pm}$ 0.28, 0.71 ${\pm}$ 0.24 and 0.74 ${\pm}$ 0.53 hr$^{-1}$, respectively. Source strengths of NO$_2$, toluene and xylene were 16.28 ${\pm}$ 7.47,31.25 ${\pm}$ 38.45 and 23.45 ${\pm}$ 19.67 ppb/hr, respectively In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City (부산광역시 지하철 내의 대기오염도 분석)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • Journal of Environmental Science International
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.

Indoor environmental alarm robot (실내환경 오염 측정장치 알람봇 구현)

  • Cho, Hae-Jin;Lee, Hye-bin;Lee, Gi-Ho;Oh, Min-u;Choi, Ji-Seung;Kim, Su-Min;Kim, Seong-Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.549-551
    • /
    • 2016
  • In this paper, With the development of modern science and technology are Sheds to stay indoors rather than outdoors space it increased significantly compared to the past. And a wide variety of research about outdoor air quality until recently, efforts are underway but the issue of air quality in the room is the fact that all considered relatively lightly. As the contamination of the room air is polluted, unlike the natural environment, a large outdoor air dilution rate, the dilution rate is very low, once the contaminated air continuously circulating exerts a very bad influence on the health of people staying in the room. In this study, movement characteristics of the person living in a room, the air measuring device for the study of the active indoor environmental control system reflects the life form to measure the quality of the measured air in real time for transmitting the information to the user of the smart devices, alarm bot It was implemented and operational applications.

  • PDF

A study on the condition of air pollution near tollbooths on highway (고속도로 요금소 주변의 대기오염 현황에 관한 연구)

  • 김신도;박성규;봉춘근;김종호;강혜진;이의상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.359-368
    • /
    • 1999
  • The outdoor and indoor air quality surrounding highway have been measured, and the study on the design of the booth shape and the air-conditioning system also has been carried out. For the first step of the work, the air quality at the Seoul tollgate on the Kyeong-bu highway was monitored over a year. The measured indoor air quality shows seasonal average concentration 85.6-92.1ppb of >;$NO_2$and the $SO_2$and CO lower than the EAQS(Environmental Air Quality Standards). The measured TSP concentration was much higher than the EAQS. In conclusion, there is necessity to improve the working environment of the tollbooths on highways, and the current air-conditions need to be modify for the purpose. In the process of modifying the air-conditioning system, particulate pollutants needs to be considered processing and the priority needs to be put on the booths for big vehicles.

  • PDF

Measuring the Effectiveness of an Ecosystem Service to Regulate Air Quality in Wetland, South Korea

  • Kim, Jung In;Lee, Kyungeun;Yeo, Inae;Choi, Tae-Young;Lee, Beom Hee;Jung, Pil Mo;Joo, Wooyeong
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.2 no.1
    • /
    • pp.62-69
    • /
    • 2021
  • This study aimed to verify the suitability of an air quality regulating service for wetland ecosystem service evaluation by investigating the effect of reducing particulate matter (PM) on vegetation in wetlands. We installed tunnel-type experimental plots at Yonghwasil Pond in the National Institute of Ecology and set up the input and output of PM by applying the natural vegetation of the relevant wetlands. We took measurements by replicating four different conditions four times each. The air quality regulating service in each experimental plot was measured based on PM10 concentration; further, the difference between the input and the output concentration of PM passing through the Phragmites australis community tunnel was measured using a light scattering method. For the Phragmites australis community in the outdoor conditions and bare land, the PM concentration was measured with the same specifications as tunnel-type experimental plots without setting up the input and output. For the tunnel-type experimental plots, PM10 concentration was significantly lower in the output than in the input. Furthermore, in the outdoor conditions, a comparison between the Phragmites australis community and bare land showed that the concentration was relatively low in the former than in the latter. This confirmed the PM reducing effect due to the blockage and absorption of PM depending on the growth of Phragmites australis. Based on the results of this study, we assessed the air quality regulating service in wetlands as an evaluation indicator.

Desiccant Air Conditioning System market and Prospect (데시칸트 공조시장 및 전망)

  • Park, Seung-Tae;Chung, Kwang-Seop;Kim, Young-Il;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.230-235
    • /
    • 2009
  • The Desiccant air conditioning system has been designed as the industrial dehumidifier under the leadership of developed countries, considering CFC problems in 1990, indoor air quality(IAQ) and outdoor air intake rates. This could make the technical differences between them and us. Nowadays, domestic technology has been developed in some parts but there still remain many challenges to be managed. In this study, these tasks would be handled according to the desiccant air conditioning system market and prospects.

  • PDF