• 제목/요약/키워드: outdoor air quality

검색결과 208건 처리시간 0.032초

겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염 (Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter)

  • 김종범;이광재;류성희;이재영;우성호;이승복;김경환;윤성택;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

서울시 지하철 터널 내 입자상물질의 농도 특성 및 오염형태 분류 (Characteristics of Particulate Matter Concentration and Classification of Contamination Patterns in the Seoul Metropolitan Subway Tunnels)

  • 이은선;이태정;박민빈;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.593-604
    • /
    • 2017
  • The suspended particulate matter(PM) was measured in subway tunnel of Seoul Line 1 to 9 in order to evaluate the pollution degree and characteristics of the PM in the subway tunnel. Also, to analyze the effect of outdoor aerosol concentration on the PM concentration of subway tunnels, the ambient PM concentration around the subway station was extracted by spatial analysis using $PM_{10}$ data of Seoul air pollution monitoring network. Finally, in order to understand pollution pattern in the Seoul subway tunnels, cluster analysis was performed based on input data set such as PM levels in tunnel, tunnel depth, length, curvature radius, outdoor ambient air pollution levels and so on. The average concentration of $PM_{10}$, $PM_{2.5}$, and $PM_1$ on subway tunnels were $98.0{\pm}37.4$, $78.4{\pm}28.7$, and $56.9{\pm}19.2{\mu}g/m^3$, respectively. As a result of the cluster analysis, tunnels from Seoul subway Line-1 to Line-9 were classified into five classes, and the concentrations and physical properties of the tunnels were compared. This study can provide a method to reduce PM concentration in tunnel for each pollution pattern and provide basic information about air quality control in Seoul subway tunnel.

이산화티탄 광촉매 적용 광투과 콘크리트 역학특성 평가 (Evaluation of the Mechanical Properties of Light Transmitting Concrete using TiO2 Photocatalyst)

  • 서승훈;권시원;오상근;김병일
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.63-64
    • /
    • 2019
  • Due to the rapid deterioration of the domestic atmosphere, people are suffering from inconveniences such as wearing fine dust masks all the time during outdoor activities. In this study, light transmitting concrete, LEFC(Light Emotion Friendly Concrete), using TiO2 photocatalyst was produced. Since the characteristics of LEFC where acrylic rods are inserted require self-consolidating performance, the purpose was to utilize UHPC(Ultra High Performance Concrete) materials to obtain high-flowability. Further, the compressive strength and flexural strength were evaluated to prevent the reduction of epidemiological performance by utilizing UHPC materials. As such, a basic study was carried out to develop LEFC materials using photocatalyst that can purify the air and stimulate human sensibility.

  • PDF

지하에 위치한 방사선종양학과에서의 실내공기 질 평가 (Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground)

  • 김원택;신용철;강동묵;기용간;김동원;권병현
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.243-252
    • /
    • 2005
  • 목적: 지하에 위치한 방사선치료 관련시설 내의 실내공기 질은 근무자뿐만 아니라 장기간 치료받는 환자들의 건강에도 중요하다. 저자들은 근무자들의 빌딩증후군 증상유무의 확인과 함께 실내공기 질과 관련된 여러 인자들을 측정, 분석하여 그 원인을 찾고 해결책을 제시하고자 하였다. 대상 및 방법: 근무자들을 대상으로 자각증상 및 근무환경 인식과 관련된 설문조사를 하였고, 예비조사를 바탕으로 실내공기 질과 관련된 항목들(온 습도, 미세먼지, 이산화탄소, 일산화탄소, 포름알데히드, 총휘발성유기화합물, 라돈)에 대해 근무자들이 주로 머무르는 지역들을 중심으로 일정기간 측정하였다. 아울러 환기(공조) 시스템의 효율 및 주변 환경에 대한 평가를 동시에 진행하였으며, 실외공기와의 비교평가를 위해 1층(실외)에서도 같은 항목들을 측정하였고, 측정 자료들은 국내외 환경관련 기관들의 권고 수치를 기준으로 각각 평가하였다. 결과: 설문조사에서 근무자들은 악취, 습도, 먼지 등에 대해 불만족을 보였으며, 근골격계 증상, 신경계 증상, 점막 자극 증상 등을 주로 호소하였다. 대부분의 실내공기 질 관련 항목들은 기준치를 넘지 않았으나 총휘발성유기화합물 수치가 기존 미국 사무실 측정 수치에 비해 $3{\sim}4$배 높게 나왔다. 환기 횟수나 환기량에서는 문제가 없었으나 실외공기 유입구와 실내공기 배출구의 위치 문제로 인해 오염된 공기의 유입 가능성이 있었다. 총휘발성유기화합물을 배출할 수 있는 현상액과 같은 화학물질의 관리에 주의가 필요했으며, 오염된 공기의 재유입 문제를 해결하기 위해 환기 시스템의 위치조정이 시급한 상황이었다. 결론: 저자들은 실내공기 질에 대한 평가에서 일부 화학물질 및 부적절한 환기 시스템으로 인해 근무자들이 주관적인 증상을 호소할 수 있음을 확인하였다. 지하 공간에서 장시간 거주하는 근무자들의 근무여건 개선과 함께 면역저하를 동반한 환자들의 건강관리를 위해 실내공기 질에 대한 평가는 반드시 필요하며, 그 자료를 바탕으로 향후 방사선종양학과의 설계나 기존 시설의 환경개선 등에 적극적으로 이용해야 하겠다.

Air Pollution Exposure and Cardiovascular Disease

  • Lee, Byeong-Jae;Kim, Bumseok;Lee, Kyuhong
    • Toxicological Research
    • /
    • 제30권2호
    • /
    • pp.71-75
    • /
    • 2014
  • Ambient air pollution (AAP) and particulate matters (PM) have been closely associated with adverse health effects such as respiratory disease and cardiovascular diseases. Previous studies have examined the adverse health effects associated with short- and long-term exposure to AAP and outdoor PM on respiratory disease. However, the effect of PM size ($PM_{2.5}$ and $PM_{10}$) on cardiovascular disease has not been well studied. Thus, it remains unclear how the size of the inhalable particles (coarse, fine, or ultrafine) affects mortality and morbidity. Airborne PM concentrations are commonly used for ambient air quality management worldwide, owing to the known effects on cardiorespiratory health. In this article, we assess the relationship between cardiovascular diseases and PM, with a particular focus on PM size. We discuss the association of $PM_{2.5}$ and $PM_{10}$, nitrogen dioxide ($NO_2$), and elemental carbon with mortality and morbidity due to cardiovascular diseases, stroke, and altered blood pressure, based on epidemiological studies. In addition, we provide evidence that the adverse health effects of AAP and PM are more pronounced among the elderly, children, and people with preexisting cardiovascular and respiratory conditions. Finally, we critically summarize the literature pertaining to cardiovascular diseases, including atherosclerosis and stroke, and introduce potential studies to better understand the health significance of AAP and PM on cardiovascular disease.

에어컨 배관 시스템의 형상 최적설계 (Shape Optimization of an Air Conditioner Piping System)

  • 민준홍;최동훈;정두한
    • 한국소음진동공학회논문집
    • /
    • 제19권11호
    • /
    • pp.1151-1157
    • /
    • 2009
  • Ensuring both product quality and reducing material cost are important issue for the design of the piping system of an air conditioner outdoor unit. This paper describes a shape optimization that achieves mass reduction of an air conditioner piping system while satisfying two design constraints on resonance avoidance and the maximum stress in the pipes. In order to obtain optimized design results with various analysis fields considered simultaneously, an automated multidisciplinary analysis system was constructed using PIAnO v.2.4, a commercial process integration and design optimization(PIDO) tool. As the first step of the automated analysis system, a finite element model is automatically generated corresponding to the specified shape of the pipes using a morphing technique included in HyperMesh. Then, the performance indices representing various design requirements (e.g. natural frequency, maximum stress and pipe mass) are obtained from the finite element analyses using appropriate computer-aided engineering(CAE) tools. A sequential approximate optimization(SAO) method was employed to effectively obtain the optimum design. As a result, the pipe mass was reduced by 18 % compared with that of an initial design while all the constraints were satisfied.

박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구 (A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum)

  • 정성욱
    • 한국실내디자인학회논문집
    • /
    • 제17권2호
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

학교 교실 공기질 관리를 위한 건강영향 기반 실내공기질지수 개발 (Indoor Air Quality Index for School Classrooms Based on Health Effects)

  • 김도윤;권지유;이태정;박영구;조영민
    • 환경영향평가
    • /
    • 제30권6호
    • /
    • pp.380-392
    • /
    • 2021
  • 어린 학생들에 대한 HQ (Hazard Quotient) 기반으로 학교교실 실내 공기질 지수 (IAQI-S)를 개발하였다. IAQI-S는 PM10, PM2.5, CO2를 포함하며, IAQI-S의 기준농도는 지정된 HQ값을 통해 산출하였다. 본 연구에서 개발한 IAQI-S를 이용하여 2017년 11월부터 2020년 12월까지 실시간으로 측정한 전국 46개 학교 123개 학급을 평가해보았다. 종합지수 평가 결과, PM10의 93.1%, PM2.5의 94%가 '좋음'과 '보통' 등급에 포함되었다. 8시간 예측 이동 평균을 기반으로 한 IAQI-S는 CAI(Comprehensive Air-quality Index) 및 외국에서 발표되었던 IAQI와 비교하였다. IAQI-S는 CO2를 포함하며 대기질지수 (CAI)에 비해 더 엄격한 수준으로 구성되어 있음을 알 수 있었다.

실내 환경오염 감소를 위한 건축마감 재료에 관한 연구 (A study on the finishing materials for Reduction of Indoor pollution)

  • 김자경;남경숙
    • 한국실내디자인학회논문집
    • /
    • 제16권2호
    • /
    • pp.303-313
    • /
    • 2007
  • Nowadays, according to many studies, indoor space's pollution level is two to ten times higher than outdoor space's. This result arouses our attention. The major causes of deterioration of indoor air quality are the lack of ventilation caused by draught-proofing and insulation construction, and harmful chemical substances emitted from building materials, office machine and furniture. Therefore, we are continuing research to find the method for healthful house and production of many forms of well-being goods. However, because of exaggerated advertisements and the lack of accurate information, consumers choose the products whose performance is not verified. Therefore, this study investigates the actual conditions of pollution by building materials and the extent of the health damage by this pollution, and suggests the method for minimizing indoor pollution in aspect of indoor environment control and the use of environment friendly materials. But the building materials presented in this study are limited to the environment friendly construction materials that are in circulation In domestic market because this research is primarily aimed to give domestic consumers the standard for selecting this materials.

아파트 실내·외 미세먼지(PM10, PM2.5)와 블랙카본(Black Carbon)의 계절별 농도 및 시간대별 분포 특성 사례연구 (A Case Study on Distribution Characteristics of Indoor and Outdoor Particulate Matter (PM10, PM2.5) and Black Carbon (BC) by Season and Time of the Day in Apartments)

  • 박신영;윤단기;공혜관;강상현;이철민
    • 한국환경보건학회지
    • /
    • 제47권4호
    • /
    • pp.339-355
    • /
    • 2021
  • Background: Particulate matter (PM10, PM2.5) and black carbon contribute to poor air quality in urban areas, and can also affect indoor environments. Exposure to PM can be associated with respiratory and lung diseases. Objectives: This study investigated the indoor and outdoor concentration distribution patterns of PM10, PM2.5, and black carbon at an apartment building, a typical residential space in the metropolitan areas of South Korea, by season, day of the week (weekday vs. weekend), and time of the day. It aims to obtain foundational data for the effective management of pollutants and investigate the difference in pollution levels between indoor and outdoor environments. Methods: Indoor and outdoor concentrations of PM and black carbon were measured at an apartment building located in Namyangju, Gyeonggi-do Province, using dust sensors and an Aethalometer AE51 (AethLabs, San Francisco, CA, USA) over the course of a year from June 2020 to May 2021. The concentration distribution patterns were analyzed by season and time of day. Results: PM10 and PM2.5 concentrations in the outdoor environment were higher than those in the indoor environment, regardless of the season. By contrast, the indoor black carbon concentration was higher than that in the outdoor environment during summer and autumn. The concentrations of PM10, PM2.5 and black carbon were found to be higher on weekdays than during weekends, especially during rush hour, with concentrations of 25.92~56.58 ㎍/m3, 21.12~44.82 ㎍/m3, 0.63~3.40 ㎍/m3. Conclusions: The outdoor concentrations of PM10, PM2.5, and black carbon were higher during the weekdays, especially during rush hour, than during weekends. This study is expected to provide basic data for the health management of apartment occupants because it is measured over a period of more than one year.