• 제목/요약/키워드: outdoor

검색결과 4,125건 처리시간 0.026초

발전소 환경소음 예측 (Environmental Noise Prediction of Power Plants)

  • 조대승;유병호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.452-459
    • /
    • 1997
  • For computer aided design and construction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

An Analysis on Building Shading Plan for a City Hall considering Energy Saving

  • Kim, Jin Lee;No, Sang Tae
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: Recently, many public office buildings which were built by curtain wall increased rapidly, but the results of the investigation of the government, these buildings have been found that the heating and cooling thermal load is high, and showed low energy efficiency. Method: To evaluate the effects by applying outdoor louver and indoor blind, which can control solar radiation in order to reduce the heating and cooling load of public office building which was built by glass curtain wall. The heating and cooling load was calculated via Energyplus, building and outdoor louver, indoor blind were modeled by Google sketchup connected to Energyplus. Result: The results of this study were as follows; the case of applying various outdoor louver, the heating and cooling load all decreased as compared to the case without applying outdoor louver, the case of applying indoor blind, the heating and cooling load decreased as compared to the case without applying indoor blind, but indoor blind showed low energy performance comparing outdoor louver.

중앙공조 및 개별공조에서의 외조기 적용 (Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning)

  • 박승태;김영일;이태호;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

가중화된 GPS 정보와 지도정보를 활용한 실외 이동로봇의 위치추정 (Outdoor Localization of a Mobile Robot Using Weighted GPS Data and Map Information)

  • 배지훈;송재복;최지훈
    • 로봇학회논문지
    • /
    • 제6권3호
    • /
    • pp.292-300
    • /
    • 2011
  • Global positioning system (GPS) is widely used to measure the position of a vehicle. However, the accuracy of the GPS can be severely affected by surrounding environmental conditions. To deal with this problem, the GPS and odometry data can be combined using an extended Kalman filter. For stable navigation of an outdoor mobile robot using the GPS, this paper proposes two methods to evaluate the reliability of the GPS data. The first method is to calculate the standard deviation of the GPS data and reflect it to deal with the uncertainty of the GPS data. The second method is to match the GPS data to the traversability map which can be obtained by classifying outdoor terrain data. By matching of the GPS data with the traversability map, we can determine whether to use the GPS data or not. The experimental results show that the proposed methods can enhance the performance of the GPS-based outdoor localization.

한국형 Green Roof System 개발을 위한 Proyotype 제안 (A Study on the Development of Prototype for Green Roof System in Korea)

  • 김현수
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.3-11
    • /
    • 2003
  • The purpose of this study is to develope an available outdoor insulation construction for the green roof system in Korea. On its own economical and structural problems of constructional risk, the typical outdoor insulation construction on the korean spot does not function efficiently with the green roof. Therefore, this study consists of four main contents as follows: 1. The objectives of the study are established by analysing the problems of the typical in- and outdoor roof insulation system in korea. 2. The foreign outdoor insulation systems for the green roof are clarified to find out an acceptable prototype for Korea. 3. According to loadtest, the prototype, which has a waterproof on the thermal insulation, is tested to demonstrate the structural safety. 4. The U-value test of the prototype on KS F 2277 brings the thermal performance of the green roof system, which can influence the thickness of the insulation.

외기이용 하이브리드 냉각탑 성능해석 (Numerical Analysis on the Performance of a Outdoor Air Cooled Heat exchanger for Cooling Tower)

  • 김성일;이욱현;이계중;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2322-2327
    • /
    • 2008
  • This paper is to provide analysis model that can be used to investigate the improvement in energy efficiency for cooling tower by using fresh air. Numerical analysis of Air-cooled heat exchanger for single-phase flow with variations of outdoor air temperature has been performed. A complete set of correlations of the heat transfer in both refrigerant and air sides was employed for predicting the heat transfer rate. The numerical results derived from the correlations were verified with experimental results. The energy consumption for a hybrid cooling tower has been compared for variation of a outdoor air temperature. The results showed that the hybrid cooling tower in low outdoor temperature offers a significant improvement in energy efficiency. The thermal analysis aids significantly in the solution of the design problem of hybrid cooling tower.

  • PDF

옥외 온열환경 평가시뮬레이션 기법의 개발 (Development of an assessment tool for outdoor thermal environment)

  • 지용승;황효근;임종연;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.38-43
    • /
    • 2009
  • Since most of the existing CFD simulation about thermal environment was limited as indoor environment, it is not appropriate to adopt the same method for external thermal environment, because the solar radiation highly affect the outdoor thermal environment. Thus, in case of assessing the outdoor thermal environment, the radiation calculation is very important. In this study, as a new method to evaluate the outdoor thermal environment, coupled simulation of convection and radiation will be proposed.

  • PDF

옥외 주상용 몰드 변압기인 적용 기술 (The Applied Technology of Mold Transformer for Outdoor Use)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.23-28
    • /
    • 2000
  • Insulator systems using resin casting apparatus are useful to realize the high capacity, small size, and combined electric power equipments, and are expected to bring various advantages. In Korea, epoxy resin molded apparatus have been restricted to indoor uses till now. On the other hand, in Europe, molded insulators and transformers and so forth have been practically used since the former half of 1960's. Recently, investigation on epoxy resin materials and molded apparatus for outdoor use have ben intensively carried out. Probably, this is because electric power outdoor apparatus such as distribution transformer can be given multi-functions by using outdoor epoxy resin compound This study describes the trend on the development of epoxy mold transformers, and important technologies applied for outdoor use.

  • PDF

구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용 (Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique)

  • 김규식;진심원;정인화;이정우;강연준
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

부산 지역 과학 교육 자원 지도를 활용한 체험학습의 환경교육적 효과 (Effects of Outdoor Activities Utilizing Regional Science Education Resource Map (RSM) in Busan)

  • 유선미;김선영
    • 한국환경교육학회지:환경교육
    • /
    • 제24권3호
    • /
    • pp.44-55
    • /
    • 2011
  • This study examined the effects of RSM (Regional Science education resource Map), developed and provided by Busan metropolitan city Office of Education, at high schools in Busan. Two group of students, who were in the same level of achievement as well as other environmental conditions, participated in this study. Twenty nine of students as an experimental group experienced outdoor activities utilizing RSM, while thirty of students as a control group did not participate in any outdoor activities. The results indicated that compared to the control group of students, the experimental group of students represented a significant improvement in students' environmental attitudes, local ecological interest and eco-friendly behavior. The teachers who guided outdoor activities utilizing RSM suggested that RSM needs to be further subdivided by seasons as well as local districts. They also suggested that RSM needs to be linked with a school curriculum.

  • PDF