• 제목/요약/키워드: out-of system exit

검색결과 119건 처리시간 0.023초

격자크기에 따른 Gun식 가스버너의 스월유동에 대한 난류모델평가 (Evaluation of Turbulent Models on the Swirling Flow of a Gun-Type Gas Burner According to the Mesh Size)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권3호
    • /
    • pp.59-65
    • /
    • 2014
  • The computational fluid dynamics was carried out to evaluate turbulent models on the swirling flow of a gun-type gas burner(GTGB) according to the mesh size. The commercial SC/Tetra software was used for a steady-state, incompressible and three-dimensional numerical analysis. In consequence, the velocity magnitude from the exit of a GTGB and the flowrate predicted by the turbulent models of MP k-${\varepsilon}$, Realizable k-${\varepsilon}$ and RNG k-${\varepsilon}$ agree with the results measured by an experiment very well. Moreover, the turbulent kinetic energy predicted by the turbulent model of standard k-${\varepsilon}$ with mesh type C only agrees with the experimental result very well along the radial distance. On the other hand, the detailed prediction of the information of swirling flow field near the exit of a GTGB at least needs a CFD analysis using a fairly large-sized mesh such as a mesh type C.

그릴 스펙트로미터를 적용한 하다마드 트랜스폼 이미징 스펙트로미터에 대한 연구 (A Study on Hadamard Transform Imaging Spectrometers utilizing Grill Spectrometers)

  • 박영재;박진배;최윤호;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.601-603
    • /
    • 1998
  • In this paper, Hadamard transform imaging spectrometers utilizing Grill spectrometers are proposed. General Hadamard Transform Spectrometers (HTS) carry out one-encoding through input masks, but Grill spectrometers carry out double-encoding through entrance and exit masks. Thus Grill spectrometers increase the signal-to-noise ratio by double-encoding. we reconfigure the system by using the Grill spectrometers which use a left cyclic S-matrix instead of the conventional right cyclic one. Then, we model the system and apply the mask characteristics method, i.e. $T^{I}$ method, to complete fast algorithm. Through computer simulations, we want to prove the superiority of the proposed system by comparing with the conventional HTS. From Observations concerning the average mean square error(AMSE) associated with estimates from the $T^{I}$ spectrum-recovery method, the relative performances of the two systems are compared.

  • PDF

셀 입구 예열방법에 따른 가압형 고체산화물 연료전지/가스터빈 하이브리드 시스템의 성능 비교 해석 (Comparative Performance Analysis of Pressurized Solid Oxide Fuel Cell / Gas Turbine Hybrid Systems Considering Different Cell Inlet Preheating Methods)

  • 양원준;김재환;김동섭
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.722-729
    • /
    • 2005
  • Design analysis of the solid oxide fuel cell and gas turbine combined power system is performed considering different methods for preheating cell inlet air. The purpose of air preheating is to keep the temperature difference between cell inlet and outlet within a practical design range thus to reduce thermal stress inside the cell. Three different methods considered are (1) adopting a burner in front of the cell, (2) adopting a preheater (heat transfer from the main combustor) in front of the cell and (3) using recirculation of the cathode exit gas. For each configuration, analyses are carried out for two values of allowable maximum cell temperature difference. Performance characteristics of all cases are compared and design limitations are discussed. Relaxation of the cell temperature difference (larger difference) is proved to ensure higher efficiency. Recirculation of the cathode exit gas exhibits better performance than other methods and this advantage becomes more prominent as the constraint of the cell temperature difference becomes more severe (smaller temperature difference).

유비쿼터스와 자동화 기술을 이용한 기숙사 관리 시스템 개발 (The Development of a Dormitory Management System Using the Ubiquitous and Automation Technology)

  • 장재혁;심갑식
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2009
  • 현재 RFID를 이용한 활용분야는 의료, 유통, 제조, 보안 등 다양하게 확장되고 있다. 또한, 학교에서도 도서대출 및 학생출석 관리 등의 RFID를 이용한 시스템에 대한 관심이 높아지고 있다. 본 논문에서 개발한 기숙사 관리 시스템은 서포트 프로그램, 객실관리 프로그램, 관리자 프로그램, 모바일 프로그램 등으로 구성된다. 서포트 프로그램은 학생들의 기숙사 출입 내역을 웹에서 확인할 수 있으며, 관리자와 학생이 각각의 모드로 접근하여 그 정보를 확인 할 수 있다. 객실관리 프로그램은 입력받은 RFID의 태그 정보로 데이터베이스 서버에 저장된 정보를 조회한 후, 출입여부와 전원사용을 관리한다. 관리자 프로그램은 객실관리 프로그램의 운영을 위해 필요한 객실상태 및 객실 내 비품에 대한 입력 및 수정이 가능하고, 학생의 입실 및 객실 사용현황 정보 등을 설정하고 검색할 수 있다. 모바일 프로그램에서는 관리자가 입실한 학생과 미 입실한 학생의 상태를 확인할 수 있고, 이와 동시에 미 입실한 학생의 자세한 인적사항을 확인할 수 있다.

산소분리기술을 사용한 연료전지/순산소연소 발전시스템 해석 (Analysis of Solid Oxide Fuel Cell/Oxy-fuel Combustion Power Generation System Using Oxygen Separation Technology)

  • 박성구;김동섭;손정락;이영덕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 2008
  • This study aims to devise and analyze a power generation system combining the solid oxide fuel cell and oxy-fuel combustion technology. The fuel cell operates at an elevated pressure, a constituting a SOFC/gas turbine hybrid system. Oxygen is extracted from the high pressure cathode exit gas using ion transport membrane technology and supplied to the oxy-fuel power system. The entire system generates much more power than the fuel cell only system due to increased fuel cell voltage and power addition from oxy-fuel system. More than one third of the power comes out of the oxy-fuel system. The system efficiency is also higher than that of the fuel cell only system. Recovering most of the generated carbon dioxide is major advantage of the system.

  • PDF

후방산란법(RBS)/양성자 여기 X-선 방출법(PIXE)을 이용한 다층자성박막의 두께 및 조성 정량분석 (Analysis of Magnetic Multi-layers by RBS and PIXE)

  • 송종한;김태곤;전기영;황정남;신윤하;김영만;장성호;김광윤
    • 한국자기학회지
    • /
    • 제11권6호
    • /
    • pp.272-277
    • /
    • 2001
  • FeMr에 의해 교환 바이어스된 synthetic antiferromagnet(CoFe/Ru/CoFe)을 가진 Top Ta/NiFe/CoFe/Cu/CoFe/Ru/CoFe/FeMn/Ta 스핀 밸브 구조를 마그네트론 스퍼터링법에 의해 증착하였다. 이러한 스핀 밸브에서는 자유층, 구속층등의 두께 및 조성이 층간 결합력의 세기를 비롯한 자성특성에 영향을 미치게 된다 후방산란법은 두께 및 조성에 대한 절대정량이 가능하며 비파괴 분석법이라는 장점을 지니고 있으나, 원자번호가 20번 이상인 주기율표상의 인접원소로 이루어진 자성박막을 분석하는데 있어서 신호의 중첩현상으로 인해 분석이 불가능하였다 본 연구에서는 element-specific 한 분석기술인 양성자 여기 X선 검출법과, 절대 정량이 가능하고 깊이분해능을 현저히 향상시킨 grazing-exit 후방산란법 (RBS : Rutherford Backscattering Spectrometry)을 동시에 사용하여 상호 보완적인 분석을 함으로써 스핀밸브에 대한 성분 및 두께에 대한 정량분석을 수행하였다. 이를 위하여 먼저 spin valve 구조에서 자성층인 NiFe, CoFe, FeMn 단일층이 증착된 시료에 대한 표준화를 수행함으로써 spin valve 구조에서 grazing-exit 후방산란 스펙트럼 상의 중첩된 신호를 Simulation을 통하여 분리가 가능하였으며, 특히 Ru층의 두께는 단위의 정확도로 측정이 가능 하였다

  • PDF

증발디젤분무의 거동특성해석을 위한 계산기법 적용에 관한 기초 연구 (Basic Study on the Application of a Computational Technique to Behavior Characteristics Analysis of the Evaporative Diesel Spray)

  • 염정국
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.5-12
    • /
    • 2010
  • In this study, an analysis of evaporative diesel spray and an usefulness of a general-purpose program, ANSYS CFX release 11.0, are investigated through the comparison and investigation of the experimental results carried out under an evaporative field, in which there is phase transition, by an exciplex fluorescence method and the results analyzed by the CFX program. The diesel fuel called n-Tridecane, $C_{13}H_{28}$, is injected from a single-hole nozzle (l/d=1.0mm/0.2mm) into a constant volume chamber under a high temperature and pressure. In the same condition as the experimental condition, the analysis was carried out. Both results of the spray tip penetration were almost coincident at each time. The results have validated the usefulness of this analysis. As a result, if the ambient pressure is high, the spray tip penetration will be shortened and move toward the nozzle exit.

공기식 흡수기의 유동 방향에 따른 $5kW_t$급 접시형 태양열 집열기의 열성능 분석 (Thermal Performance of Air receiver with a Change of Flow direction for Dish Solar Collector)

  • 서주현;강경문;이주한;오상준;서태범
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.182-185
    • /
    • 2008
  • The thermal performance of air receiver with a change of flow direction for dish solar collector. This system is installed and operated in Incheon, Korea. The thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. Experiments are being carried out to investigate the thermal performance variation of the receivers with several design parameters such as the shape of the receiver, the flow directions and the flow rate of air. First, air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. Second, air flows into the backside of the receiver, Which is the forward side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 1 exit. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected.

  • PDF

Flexible Intelligent Exit Sign Management of Cloud-Connected Buildings

  • Lee, Minwoo;Mariappan, Vinayagam;Lee, Junghoon;Cho, Juphil;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • 제5권1호
    • /
    • pp.58-63
    • /
    • 2017
  • Emergencies and disasters can happen any time without any warning, and things can change and escalate very quickly, and often it is swift and decisive actions that make all the difference. It is a responsibility of the building facility management to ensure that a proven evacuation plan in place to cover various worst scenario to handled automatically inside the facility. To mapping out optimal safe escape routes is a straightforward undertaking, but does not necessarily guarantee residents the highest level of protection. The emergency evacuation navigation approach is a state-of-the-art that designed to evacuate human livings during an emergencies based on real-time decisions using live sensory data with pre-defined optimum path finding algorithm. The poor decision on causalities and guidance may apparently end the evacuation process and cannot then be remedied. This paper propose a cloud connected emergency evacuation system model to react dynamically to changes in the environment in emergency for safest emergency evacuation using IoT based emergency exit sign system. In the previous researches shows that the performance of optimal routing algorithms for evacuation purposes are more sensitive to the initial distribution of evacuees, the occupancy levels, and the type and level of emergency situations. The heuristic-based evacuees routing algorithms have a problem with the choice of certain parameters which causes evacuation process in real-time. Therefore, this paper proposes an evacuee routing algorithm that optimizes evacuation by making using high computational power of cloud servers. The proposed algorithm is evaluated via a cloud-based simulator with different "simulated casualties" are then re-routed using a Dijkstra's algorithm to obtain new safe emergency evacuation paths against guiding evacuees with a predetermined routing algorithm for them to emergency exits. The performance of proposed approach can be iterated as long as corrective action is still possible and give safe evacuation paths and dynamically configure the emergency exit signs to react for real-time instantaneous safe evacuation guidance.

Helium-Air Exchange Flours Through Partitioned Opening and Two-Opening

  • Kang, Tae-il
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.251-259
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through partitioned opening and too-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature engineering test reactor. A test vessel with the too types of small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed to measure the exchange now rate. Upward flow of the helium and downward flow of the air in partitioned opening system interact out of entrance and exit of the opening. Therefore, an experiment with too-opening system is made to investigate effect of the fluids interaction of partitioned opening system. As a result of comparison of the exchange flow rates between too types of the opening system, it is demonstrated that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system because of absence of the effect of fluids interaction.

  • PDF