• Title/Summary/Keyword: osseointegration.

Search Result 398, Processing Time 0.027 seconds

Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study

  • Gao, EnFeng;Hei, Wei-Hong;Park, Jong-Chul;Pang, KangMi;Kim, Sun Kyung;Kim, Bongju;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.5
    • /
    • pp.312-327
    • /
    • 2017
  • Purpose: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14-24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean $0.07{\pm}0.48mm$), while the crestal bone level decreased significantly, from $2.34{\pm}0.93mm$ at baseline to $1.70{\pm}1.10mm$ at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.

Study of a "wing-type" implant on stress distribution and bone resorption at the alveolar crest

  • Park, Jong-Wook;Kim, Sin-Guen;Choi, Dong-Won;Choi, Mi-Ra;Yoon, Youn-Jin;Park, Jun-Woo;Choi, Dong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.337-342
    • /
    • 2012
  • Objectives: Implants connect the internal body to its external structure, and is mainly supported by alveolar bone. Stable osseointegration is therefore required when implants are inserted into bone to retain structural integrity. In this paper, we present an implant with a "wing" design on its area. This type of implant improved stress distribution patterns and promoted changes in bone remodeling. Materials and Methods: Finite element analysis was performed on two types of implants. One implant was designed to have wings on its cervical area, and the other was a general root form type. On each implant, tensile and compressive forces ($30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$) were loaded in the vertical direction. Stress distribution and displacement were subsequently measured. Results: The maximum stresses measured for the compressive forces of the wing-type implant were $21.5979N/m^2$, $25.1974N/m^2$, $29.7971N/m^2$, and $32.3967N/m^2$ when $30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$ were loaded, respectively. The maximum stresses measured for the root form type were $23.0442N/m^2$, $26.9950N/m^2$, $30.7257N/m^2$, and $34.5584N/m^2$ when $30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$ were loaded, respectively. Thus, the maximum stresses measured for the tensile force of the root form implant were significantly higher (about three times greater) than the wing-type implant. The displacement of each implant showed no significant difference. Modifying the design of cervical implants improves the strength of bone structure surrounding these implants. In this study, we used the wing-type cervical design to reduce both compressive and tensile distribution forces loaded onto the surrounding structures. In future studies, we will optimize implant length and placement to improve results. Conclusion: 1. Changing the cervical design of implants improves stress distribution to the surrounding bone. 2. The wing-type implant yielded better results, in terms of stress distribution, than the former root-type implant.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

Effect of magnesium and calcium phosphate coatings on osteoblastic responses to the titanium surface

  • Park, Ki-Deog;Lee, Bo-Ah;Piao, Xing-Hui;Lee, Kyung-Ku;Park, Sang-Won;Oh, Hee-Kyun;Kim, Young-Joon;Park, Hong-Ju
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.402-408
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the surface properties and in vitro bioactivity to osteoblasts of magnesium and magnesium-hydroxyapatite coated titanium. MATERIALS AND METHODS. Themagnesium (Mg) and magnesium-hydroxyapatite (Mg-HA) coatings on titanium (Ti) substrates were prepared by radio frequency (RF) and direct current (DC) magnetron sputtering.The samples were divided into non-coated smooth Ti (Ti-S group), Mg coatinggroup (Ti-Mg group), and Mg-HA coating group (Ti-MgHA group).The surface properties were evaluated using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The surface roughness was evaluated by atomic force microscopy (AFM). Cell adhesion, cell proliferation and alkaline phosphatase (ALP) activity were evaluated using MC3T3-E1 cells. Reverse transcription polymerase chain reaction (RT-PCR) analysis was performed. RESULTS. Cross-sectional SEM images showed that Mg and Mg-HA depositionson titanium substrates were performed successfully. The surface roughness appeared to be similaramong the three groups. Ti-MgHA and Ti-Mg group had improved cellular responses with regard to the proliferation, alkaline phosphatase (ALP) activity, and bone-associated markers, such as bone sialoprotein (BSP) and osteocalcin (OCN) mRNA compared to those of Ti-S group. However, the differences between Ti-Mg group and Ti-MgHA group were not significant, in spite of the tendency of higher proliferation, ALP activity and BSP expression in Ti-MgHA group. CONCLUSION. Mg and Mg-HAcoatings could stimulate the differentiation into osteoblastic MC3T3-E1 cells, potentially contributing to rapid osseointegration.

Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

  • Doh, Re-Mee;Kim, Sungtae;Keum, Ki Chang;Kim, Jun Won;Shim, June-Sung;Jung, Han-Sung;Park, Kyeong-Mee;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.363-371
    • /
    • 2016
  • PURPOSE. On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS. Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS. The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION. Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.

Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects

  • Lim, Hyun-Chang;Jung, Ronald Ernst;Hammerle, Christoph Hans Franz;Kim, Myong Ji;Paeng, Kyeong-Won;Jung, Ui-Won;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.182-192
    • /
    • 2018
  • Purpose: The purpose of the present study was to validate an experimental model for assessing tissue integration of titanium and zirconia implants with and without buccal dehiscence defects. Methods: In 3 dogs, 5 implants were randomly placed on both sides of the mandibles: 1) Z1: a zirconia implant (modified surface) within the bony housing, 2) Z2: a zirconia implant (standard surface) within the bony housing, 3) T: a titanium implant within the bony housing, 4) Z1_D: a Z1 implant placed with a buccal bone dehiscence defect (3 mm), and 5) T_D: a titanium implant placed with a buccal bone dehiscence defect (3 mm). The healing times were 2 weeks (one side of the mandible) and 6 weeks (the opposite side). Results: The dimensions of the peri-implant soft tissue varied depending on the implant and the healing time. The level of the mucosal margin was located more apically at 6 weeks than at 2 weeks in all groups, except group T. The presence of a buccal dehiscence defect did not result in a decrease in the overall soft tissue dimensions between 2 and 6 weeks ($4.80{\pm}1.31$ and 4.3 mm in group Z1_D, and $4.47{\pm}1.06$ and $4.5{\pm}1.37mm$ in group T_D, respectively). The bone-to-implant contact (BIC) values were highest in group Z1 at both time points ($34.15%{\pm}21.23%$ at 2 weeks, $84.08%{\pm}1.33%$ at 6 weeks). The buccal dehiscence defects in groups Z1_D and T_D showed no further bone loss at 6 weeks compared to 2 weeks. Conclusions: The modified surface of Z1 demonstrated higher BIC values than the surface of Z2. There were minimal differences in the mucosal margin between 2 and 6 weeks in the presence of a dehiscence defect. The present model can serve as a useful tool for studying peri-implant dehiscence defects at the hard and soft tissue levels.

Case report of a newly designed narrow-diameter implant with trapezoid-shape for deficient alveolar bone (좁은 치조골에서 사다리꼴형 디자인으로 개발된 단폭경임플란트의 증례 보고)

  • Lee, Sa Ya;Goh, Mi-Seon;Ko, Seok-Yeong;Yun, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.5
    • /
    • pp.263-276
    • /
    • 2018
  • Long-term survival and prognosis of narrow-diameter implants have been reported to be adequate to consider them a safe method for treating a deficient alveolar ridge. The objective of this study was to perform case report of narrow-diameter implants with a trapezoid-shape in anterior teeth alveolar bone. A 50-year-old male patient presented with discomfort due to mobility of all of the maxillary teeth and mandibular incisors. Due to destruction of alveolar bone, four anterior mandibular teeth were extracted. Soft tissue healing was allowed for approximately 3 months after the extraction, and a new design of implant placement was planned for the mandibular incisor area, followed by clinical and radiological evaluation. Implant placement was determined using an R2GATE surgical stent. The stability of the implants was assessed by ISQ measurements at the first and second implant surgery and after prosthetic placement. At 1 and 3 months and 1 year after implantation of the prosthesis, clinical and radiological examinations were performed. Another 50-year-old male patient presented with discomfort due to mobility of the mandibular central incisors. For the same reason as in the first patient, implant placement was carried out in the same way after extraction. ISQ measurements and clinical and radiological examinations were performed as in the previous case. In these two clinical cases, 12 months of follow-up revealed that the implant remained stable without inflammation or additional bone loss, and there was no discomfort to the patient. In conclusion, computer-guided implant surgery was used to place an implant in an optimal position considering the upper prosthesis. A new design of a narrow-diameter implant with a trapezoid-shape into anterior mandibular alveolar bone is a less invasive treatment method and is based on the contour of the deficient alveolar ridge. Through all of these procedures, we were able to reduce the number of traumas during surgery, reduce the operation time and total treatment period, and provide patients with more comfortable treatment.

  • PDF

Fractal Analysis of Peri-Implant Bone Mineral Density before and after Functional Loading on Implant (기능하중에 따른 임플란트 주변 골밀도의 변화에 대한 프렉탈 구조 분석)

  • Hong, Seong-Wan;Lee, Jae-In;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.359-370
    • /
    • 2011
  • To identify osseointegration of implants, dentists were performed the radiographic analysis. The fractal analysis methods using periapical radiographs before and after loading on implants was to evaluate whether or not significant. 30 patients who were placed implants in dental hospital of Wonkwang university were participated in this study. Total of 42 implants were analyzed. And, 14 males and 16 females aged from 22 to 73 participated in this study. The two morphologic and Fractal analysis of the one trabecular patterns in alveolar bone were done using periapical views. Two periapical views, after implant placement, and after 2 months of functional loading were analysed. The analysis was done by software, Image J(1.40s, National Institute of Health, Bethesda, USA). The data were statistically analyzed using one-way ANOVA(P<.05). Multiple comparison was done by the Tukey HSD test. The results of Fractal analysis and change in bone density around implants showed significantly different values, especially mandibles. However, in case of implants with failure, Fractal values decreased from 1.2865 to 1.1521 and 1.1135 to 1.0478.

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.