• 제목/요약/키워드: organic matter removal

검색결과 449건 처리시간 0.024초

활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성 (Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process)

  • 홍지혜;손진식
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

BDD 전극을 이용한 축산폐수 처리의 적용성 평가 (Evaluation of the Applicability of Livestock Wastewater Treatment using Boron-Doped Diamond (BDD) Electrodes)

  • 김현구;안대희
    • 한국환경과학회지
    • /
    • 제32권6호
    • /
    • pp.465-475
    • /
    • 2023
  • In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.

오존을 이용한 유기물 및 세균의 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Organic matter and Bacteria with the Use of Ozone)

  • 이관영;박상현
    • 한국산업융합학회 논문집
    • /
    • 제10권1호
    • /
    • pp.15-20
    • /
    • 2007
  • The aim of this study is to measure the removal characteristics of organic matter and bacteria with the use of ozone to reduce the problems caused by bacteria and organic matter which appear in sea-water is summer season. When the total input of ozone was $1.4mg/{\ell}O_3$, the removal rate of bacteria and E-coli from sea-water proved to be 100%. With the same input of ozone, on the other hand, the removal rate of COD turned to be relatively low, 50%, which was to the fact that sea-water consists of salt matter which is a kind of COD matter. This result supports the idea that we can keep using ozone steadily in the future to remove organic matters and bacteria from sea-water because ozone destructs relatively less salt matter in sea-water. Also, the treatment effect rate of SS, turbidity and organic matters such as $NH_3$-N, $NO_3$-N etc, was very high. As a result, we assume that the treatment of organic matter in sea-water with ozone is very effective

  • PDF

Removal of Organic Matter and Nutrient in Swine Wastewater Using a Membrane System

  • Lim, Seung Joo;Kim, Sun Kyong;Lee, Yong-gu;Kim, Tak-Hyun
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.75-82
    • /
    • 2012
  • Swine wastewater was treated using a unique sequence of ion exchange membrane bed system (IEBR). Organic matter and nutrient in swine wastewater was pre-treated by electron beam irradiation. The optimal dose for solubilization of organic matter in swine wastewater ranged from 20 kGy to 75 kGy. The carbohydrates, proteins, and lipids were investigated as the solubilized organic fraction of swine wastewater and proteins and lipids mainly contained of the solubilized organic matter. The solubilization of organic matter in swine wastewater was affected by the combination effect of temperature and a dose. The average chemical oxygen demand (COD) removal efficiency under room temperature conditions was 67.1%, while that under psychrophilic conditions was 54.6%. For removal of ammonia, the removal efficiency decreased from 63.6% at $23^{\circ}C$ to 33.5% $16.8^{\circ}C$. On the other hand, the removal of phosphorus was not a function of temperature. Struvite was one of main mechanisms in anaerobic condition.

$MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명 (Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process)

  • 손희종;황영도;노재순;정철우;강임석
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.753-761
    • /
    • 2005
  • 전처리 공정에 따른 투과 flux 변화를 살펴보면 $MIEX^{(R)}$+UF 공정의 경우 응집+UF 공정에 비하여 높은 유기물 제거율을 나타내었으나 투과 flux 감소는 크게 나타났다. 따라서, 막 오염을 자세하게 규명하기 위하여 sequential filtration 실험결과 막 오염물질은 고분자 유기물질로 나타났으며, DOC 0.5 mg/L 이하의 유기물질이 막 오염 유발물질로 작용하고 있었다. 10 kDa 이하의 저분자 유기물질들은 $MIEX^{(R)}$ 처리에 의해 제거가 용이하여 막 표면에서 유기물 부하를 감소시켜 이로 인해 응집+UF공정에 비하여 투과 flux 감소율이 낮게 나타났다. $MIEX^{(R)}$+UF공정은 입자상 물질의 존재 유무에 관계없이 flux 감소율은 거의 유사한 경향을 보였으나 응집+UF공정은 용존성 유기물질만이 존재하는 시수에 비하여 입자상 물질이 존재하는 경우에 투과 flux 감소가 더 낮게 나타났다.

초순수 제조 공정에서 역삼투 막의 저농도 유기물 제거 (Removal of low concentration organic matter by reverse osmosis membranes in ultrapure water production process)

  • 이홍주;김수한
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.391-396
    • /
    • 2014
  • Ultrapure water (UPW) is water containing nothing but water molecule ($H_2O$). The use of UPW is increasing in many industries such as the thermal and nuclear power plants, petrochemical plants, and semiconductor manufacturers. In order to produce UPW, several unit processes such as ion exchange, reverse osmosis (RO), ultraviolet (UV) oxidation should be efficiently arranged. In particular, RO process should remove not only ions but also low molecular weight (LMW) organic matters in UPW production system. But, the LMW organic matter removal data of RO membranes provided by manufacturers does not seem to be reasonable because they tested the removal in high concentration conditions like 1,000 ppm of isopropyl alcohol (IPA, MW=60.1). In this study, bench-scale experiments were carried out using 4-inches RO modules. IPA was used as a model LMW organic matter with low concentration conditions less than 1 ppm as total organic carbon (TOC). As a result, the IPA removal data by manufacturers turned out to be trustable because the effect of feed concentration on the IPA removal was negligble while the IPA removal efficiency became higher at higher permeate flux.

Dissolved organic matter characteristics and bacteriological changes during phosphorus removal using ladle furnace slag

  • Noh, Jin H.;Lee, Sang-Hyup;Choi, Jae-Woo;Maeng, Sung Kyu
    • Membrane and Water Treatment
    • /
    • 제9권3호
    • /
    • pp.181-188
    • /
    • 2018
  • A sidestream contains the filtrate or concentrate from the belt filter press, filter backwash and supernatant from sludge digesters. The sidestream flow, which heads back into the sewage treatment train, is about 1-3% less than the influent flow. However, the sidestream can increase the nutrient load since it contains high concentrations of phosphorus and nitrogen. In this study, the removal of PO4-P with organic matter characteristics and bacteriological changes during the sidestream treatment via ladle furnace (LF) slag was investigated. The sidestream used in this study consisted of 11-14% PO4-P and 3.2-3.6% soluble chemical oxygen demand in influent loading rates. LF slag, which had a relatively high $Ca^{2+}$ release compared to other slags, was used to remove $PO_4-P$ from the sidestream. The phosphate removal rates increased as the slag particle size decreased 19.1% (2.0-4.0 mm, 25.2% (1.0-2.0 mm) and 79.9% (0.5-1.0 mm). The removal rates of dissolved organic carbon, soluble chemical oxygen demand, color and aromatic organic matter ($UV_{254}$) were 17.6, 41.7, 90.2 and 77.3%, respectively. Fluorescence excitation-emission matrices and liquid chromatography-organic carbon detection demonstrated that the sidestream treatment via LF slag was effective in the removal of biopolymers. However, the removal of dissolved organic matter was not significant during the treatment. The intact bacterial biomass decreased from $1.64{\times}10^8cells/mL$ to $1.05{\times}10^8cells/mL$. The use of LF slag was effective for the removal of phosphate and the removal efficiency of phosphate was greater than 80% for up to 100 bed volumes.

정수처리 과정에서의 중금속제거에 관한 연구 (Removal of Heavy Metals Through Conventional Water Treatment Processes)

  • 김중구;고영송;남상호
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.36-44
    • /
    • 1994
  • A study was carried out in order to investigate the removal efficiencies and removal characteristics of heaw metals such as Pb, Cd, Cr, Cu in raw water by one of conventional water treatment processes. The coagulants used in this study were Alum and PAC. Three kinds of water samples were provided: kaolin water, kaolin water mixed with humic acid and raw water from Han River mixed with suspended matter deposited on raw water inlet pipe. Heaw metals were added to the water samples with their respective turbidity, and jar tests were performed. In the results from heaw metal removal studies, lead might be adsorbed or exchanged on the particle surface (SS) rather than react with organic matter added. Cadmium was affected on the dissolved organic matter. Chromium was affected by the both dissolved organic matter and SS concentration, and the restabilization and the enmeshment appeared at moderate (50~80 NTU) and high (100 NTU) turbidity as defined in this experimenL The removal efficiency of copper was relatively little affected by the dissolved organic matter but by SS concentration in comparison with other heavy metals. In these studies as to the raw water turbidities and concentration of heaw metals, it is proved out that the removal efficiency on heaw metals in both cases of PAC and Alum as coagulants was not significantly different.

  • PDF

응집과 막여과 공정에서 응집제에 따른 유기물 및 THMFP제거 (Removal of natural organic matter and trihalomethane formation potential by four different coagulants during coagulation-microfiltration processes)

  • 박근영;최양훈;진용철;강선구;권지향
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.101-112
    • /
    • 2013
  • Integrated process with coagulation and microfiltration as an advanced water treatment has been expanded its application in recent years due to its superb removal of particles and natural organic matter. In usual, effectiveness of coagulation sometimes determines performance of the whole system. Several new polymeric coagulants introduced to water utilities for better efficiency were studied in this paper. Three polymeric coagulants (i.e., PACl, PACs, and PAHCs) along with alum were evaluated for removal of natural organic matter, especially for reduction of trihalomethane formation potential, for which regulation has become stringent. Turbidity removal was closely related to pH variation showing the reduced turbidity removal by PACs due to the decreases in the pH of supernants at high doses. The four coagulants showed different organic matter removal during coagulation and affected the removal in microfiltration. For instance, DOC concentration was not reduced by microfiltration when PAHCs were used however 10 % of DOC removal was observed by microfiltration with alum coagulation. Coagulation pretreatment also impacted the THM removals, i.e., approximately 30 % of THMs and 13 % of DOC was removed by microfiltration only, but 40 to 67 % of THMs and 30 % of DOC was removed by the integrated process. Strategies on selection of coagulants are needed depending on characteristics of target pollutants in raw waters.

PFR 공정의 ASBF 구조에 의한 유기물제거와 질산화의 영향에 대한 연구 (A Study on the Removal Characteristics of Dissolved Organic and Ammonia Compounds in PFR of Aerated Submerged Bio-film (ASBF) Reactor)

  • 최영익
    • 한국환경과학회지
    • /
    • 제17권11호
    • /
    • pp.1265-1271
    • /
    • 2008
  • Aerated submerged bio-film (ASBF) pilot plant has been developed. The presented studies optimized an inexpensive method of enhanced wastewater treatment. The objectives of this research were to describe pilot scale experiments for efficient removal of dissolved organic and nitrogen compounds by using ASBF reactor in plug-flow reactor (PFR) and improve understanding of dissolved organic matter and nitrogen compounds removal rates with dynamic relationships between heterotrophs and autotrophs in the fixed-film reactor. This research explores the possibility of enhancing the performance of shallow wastewater treatment lagoons through the addition of specially designed structures. This direct gas-phase contact should increase the oxygen transfer rate into the bio-film, as well as increase the micro-climate mixing of water, nutrients, and waste products into and out of the bio-film. This research also investigated the efficiency of dissolved organic matter and ammonia nitrogen removals in the ASBF. As it was anticipated, nitrification activity was highest during periods when the flow rate was lower, but it seemed to decline during times when the flow rate was highest. And ammonia nitrogen removal rates were more sensitive than dissolved organic matter removal rates when flow rates exceeded 2.2 L/min.