• Title/Summary/Keyword: organ doses

Search Result 253, Processing Time 0.027 seconds

Modification of Trunk Thickness of MIRD phantom Based on the Comparison of Organ Doses with Voxel Phantom (체적소팬텀과의 장기선량 비교를 통한 MIRD팬텀 몸통두께 수정)

  • Lee, Choon-Sik;Park, Sang-Hyun;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.199-206
    • /
    • 2003
  • Because the MIRD phantom, the representative mathematical phantom was developed for the calculation of internal radiation dose, and simulated by the simplified mathematical equations for rapid computation, the appropriateness of application to external dose calculation and the closeness to real human body should be justified. This study was intended to modify the MIRD phantom according to the comparison of the organ absorbed doses in the two phantoms exposed to monoenergetic broad parallel photon beams of the energy between 0.05 MeV and 10 MeV. The organ absorbed doses of the MIRD phantom and the Zubal yokel phantom were calculated for AP and PA geometries by MCNP4C, general-purpose Monte Carlo code. The MIRD phantom received higher doses than the Zubal phantom for both AP and PA geometries. Effective dose in PA geometry for 0.05 MeV photon beams showed the difference up to 50%. Anatomical axial views of the two phantoms revealed the thinner trunk thickness of the MIRD phantom than that of the Zubal phantom. To find out the optimal thickness of trunk, the difference of effective doses for 0.5 MeV photon beams for various trunk thickness of the MIRD phantom from 20 cm to 36 cm were compared. The optimal thunk thickness, 24 cm and 28 cm for AP and PA geometries, respectively, showed the minimum difference of effective doses between the two phantoms. The trunk model of the MIRD phantom was modified and the organ doses were recalculated using the modified MIRD phantom. The differences of effective dose for AP and PA geometries reduced to 7.3% and the overestimation of organ doses decreased, too. Because MIRD-type phantoms are easier to be adopted in Monte Carlo calculations and to standardize, the modifications of the MIRD phantom allow us to hold the advantage of MIRD-type phantoms over a voxel phantom and alleviate the anatomical difference and consequent disagreement in dose calculation.

The Dose and Risk Reduction from Adoption of Automatic mA Control in 4D CT Scans (자동전류조절기능을 사용한 4D CT 촬영시 선량 및 위험도 저감 효과)

  • Ko, Young Eun;Je, Hyoung Uk;Hwang, Yeon;Park, Sung Ho
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.267-272
    • /
    • 2015
  • In this study, the reduction of dose and risk was evaluated from using automatic mA control in 4D CT scan of patients whose organ movement was considered for gated radiotherapy. The organ doses, CTDI, effective doses from 4D CT with and without using automatic mA control were evaluated using CT-Expo program for each 10 patients of liver and lung cancer, and the risk of exposure induced death and loss of life expectancy were evaluated using PCXMC program. It was founded that there were 26.8%, and 15.5% dose reduction in organ doses and CTDI for liver and lung cancer patients and 16.5% and 19.8% risk reduction in liver and lung cancer patients. The organ doses and effective doses were evaluated for the parameter of each patient used in CT scans, and risks considering age and gender could be evaluated. It was founded that there were 21.2% dose reduction and 18.2% risk reduction in 4D CT scan using AEC for liver and lung cancer patients.

Effect of Doses of Capsaicin on the Immune Response in Rats (Rat에 있어서 Capsaicin의 투여량이 면역반응에 미치는 영향)

  • 안영근;김주영;김정훈;노권태
    • Environmental Analysis Health and Toxicology
    • /
    • v.4 no.1_2
    • /
    • pp.19-26
    • /
    • 1989
  • Experiments were performed on rats to investigate the effect of doses of capsaicin on the immune response. Olive oil and the 0.3 mg, 1.0 mg and 3.0 mg/kg administration of capsaicin in olive oil were injected intraperitoneally every day for 4 weeks. Rats were sensitized and challenged with sheep red blood cells (S-RBC). Immune responses were evaluated by organ weight, HA and HY titer, Arthus reaction, delayed type hypersensitivity (DTH) and Rosette froming cell. Following results have observed. 1) The weight of spleen and thymus were increased by doses of compared with control group, but the body weight of rats was decreased. 2) HA titer, Arthus reaction and DTH were significntly decreased by doses of capsaicin as compared with control group. 3) Rosette forming cell in spleen cells was decreased according to the increase of capsaicin doses. These results suggested that high dose of capsaicin decrease humoral and cellular immune response in rats.

  • PDF

Effective dose of cone-beam computed tomography for orthodontic analysis in pediatric patient (소아환자에서 교정분석을 위한 콘빔CT 촬영시 유효선량에 관한 연구)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.53 no.8
    • /
    • pp.558-568
    • /
    • 2015
  • Objective: The objectives of this study were to measure pediatric organ and effective doses of cone-beam computed tomography (CBCT) for orthodontic analysis and to compare them to those of panoramic and lateral cephalometric radiography, the conventional radiography for orthodontic analysis. Materials and Methods: Alphard VEGA for CBCT, Planmeca Proline XC for panoramic radiography and Orthophos CD for cephalometric radiography were used for this study. Thermoluminescent dosimeter (TLD) chips were located at 24 anatomic sites of 10-year-old anthropomorphic phantom and exposed during CBCT (C-mode; $200{\times}179mm$ FOV), panoramic and lateral cephalometric radiographic procedures at the clinical exposure settings for 10-year-old patient. Pediatric organ and effective doses were measured and calculated using ICRP 2007 tissue weighting factors. Results: Effective doses of CBCT, panoramic radiography and lateral cephlometric radiography in pediatric clinical exposure settings were $292.5{\mu}Sv$, $19.3{\mu}Sv$, and $4.4{\mu}Sv$ respectively. The thyroid gland contributed most significantly to the effective dose in all the radiographic procedures. Conclusion: Effective dose of CBCT was about 12 times to conventional radiographic procedures for orthodontic analysis in pediatric patient. The use of CBCT for orthodontic analysis should be fully justified over conventional radiography and dose optimization to decrease thyroid dose is needed in pediatric patients.

Study on Radiation dose in according to Magnification's rate in fluoroscopy (투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰)

  • Kang, Kyeong-Mi;Hong, Seon-Sook;Seong, Min-Sook;Song, Woon Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.39-44
    • /
    • 2013
  • Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy.

  • PDF

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

Favorable Control Effects of Palmijihwang-Whan on the Propylthiouracil Induced Hypothyroidism Related Rat Male Reproductive Organ Damages (팔미지황환의 Propylthiouracil로 유발된 Rat 갑상샘기능저하성 웅성 생식기 손상 제어 효과)

  • Kim, Seung-Mo
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.15 no.2
    • /
    • pp.55-67
    • /
    • 2015
  • Objectives: This study was to evaluate the effect of Palmijihwang-whan (PMJHW) aqueous extract in the regulation of hypothyroidism related reproductive organ damages in propylthiouracil (PTU)-induced rat model. Methods: PMJHW aqueous extract (yield=17.90%) were administered, once a day for 42 days from 2 weeks before start of PTU treatment as oral doses of 500, 250, and 125 mg/kg (body weight), and hypothyroidism was induced by daily subcutaneous treatment of PTU 10 mg/kg for 28 days. Results: PTU-induced hypothyroidism and related male reproductive organ damages-atrophic changes of testis, epididymis and prostate, were favorably and dose-dependently inhibited by treatment of PMJHW 500, 250, and 125 mg/kg. They also effectively regulated the PTU-induced abnormal antioxidant defense system changes in the testis. Although levothyroxine also favorably inhibited PTU-induced hypothyroidism, it deteriorated the hypothyroidism related male reproductive organ damages through testicular oxidative damages. The results suggest that oral administration of 125, 250, and 500 mg/kg of PMJHW has favorable effects on the hypothyroidism and related reproductive organ damages through augmentation of antioxidant defense system in the testis. Conclusions: This study suggest that PMJHW may be help to ameliorate the hypothyroidism and related organ damages in clinics.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

Effect of Vitamin A on the Immune Response in Mice (Vitamin A가 마우스의 면역반응에 미치는 영향)

  • 안영근;김주영;김정훈
    • YAKHAK HOEJI
    • /
    • v.31 no.6
    • /
    • pp.347-354
    • /
    • 1987
  • The effect of vitamin A on the immune response in ICR mice was studied. The effects were evaluated by immuno organ weight, peripheral circulating white blood cells, HA and HY titer, peritoneal exudate cells, RFC, Arthus reaction and DTH in mice. The spleen of mice was significantly hypertrophied by deficiency or over doses of vitamin A as compared with control group (50IU/kg). Arthus reaction, RFC and peritoneal exudate cells were sharply decreased according to the increase of vitamin A doses. The number of white blood cell was decreased according to the increase of vitamin A doses, but in the case of vitamin A 50,000 IU/kg treated group, it was significantly increased. These results suggest that deficiency or over dose of vitamin A decrease humoral and cellular immune response.

  • PDF