Modification of Trunk Thickness of MIRD phantom Based on the Comparison of Organ Doses with Voxel Phantom  

Lee, Choon-Sik (Innovative Technology Center for Radiation Safety)
Park, Sang-Hyun (Dept. of Nucelar Engineering, Hanyang University)
Lee, Jai-Ki (Dept. of Nucelar Engineering, Hanyang University)
Publication Information
Journal of Radiation Protection and Research / v.28, no.3, 2003 , pp. 199-206 More about this Journal
Abstract
Because the MIRD phantom, the representative mathematical phantom was developed for the calculation of internal radiation dose, and simulated by the simplified mathematical equations for rapid computation, the appropriateness of application to external dose calculation and the closeness to real human body should be justified. This study was intended to modify the MIRD phantom according to the comparison of the organ absorbed doses in the two phantoms exposed to monoenergetic broad parallel photon beams of the energy between 0.05 MeV and 10 MeV. The organ absorbed doses of the MIRD phantom and the Zubal yokel phantom were calculated for AP and PA geometries by MCNP4C, general-purpose Monte Carlo code. The MIRD phantom received higher doses than the Zubal phantom for both AP and PA geometries. Effective dose in PA geometry for 0.05 MeV photon beams showed the difference up to 50%. Anatomical axial views of the two phantoms revealed the thinner trunk thickness of the MIRD phantom than that of the Zubal phantom. To find out the optimal thickness of trunk, the difference of effective doses for 0.5 MeV photon beams for various trunk thickness of the MIRD phantom from 20 cm to 36 cm were compared. The optimal thunk thickness, 24 cm and 28 cm for AP and PA geometries, respectively, showed the minimum difference of effective doses between the two phantoms. The trunk model of the MIRD phantom was modified and the organ doses were recalculated using the modified MIRD phantom. The differences of effective dose for AP and PA geometries reduced to 7.3% and the overestimation of organ doses decreased, too. Because MIRD-type phantoms are easier to be adopted in Monte Carlo calculations and to standardize, the modifications of the MIRD phantom allow us to hold the advantage of MIRD-type phantoms over a voxel phantom and alleviate the anatomical difference and consequent disagreement in dose calculation.
Keywords
MIRD phantom; Zubal voxel phantom; organ dose; modification;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W.S. Snyder, M.R. Ford, G.G. Warner, and HL Fisher, 'Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom', MIRD Pamphlet No 5, J. Nucl. Med. 10(Suppl. 3) (1969)
2 International Commission of Radiological Protection, 'Report of the Task Group on Reference Man', ICRP Publication 23, Pergamon Press (1975)
3 D.G. Jones, 'A realistic anthropomorphic phantom for calculating organ doses arising from external photon irradiation', Radiat. Prot. Dosim. 72(1), 21-29 (1997)
4 T.J. Smith, A.W. Phipps, N. Petoussi-Hena, and M. Zankl, 'Impact on internal doses of photon SAFs derived with the GSF adult male voxel phantom', Health Phys. 80(5), 477-485 (2001)
5 R. Kramer, J.W. Vieira, H.J. Khoury, F.RA. Lima, and D. Fuelle, 'All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry', Phys. Med. Biol., 48, 1239-1262 (2003)   DOI   ScienceOn
6 I.G. Zubal, C.R Harrell, E.O. Smith, Z. Rattner, G. Gindi, and P.B. Hoffer, Computerized three-dimensional segmented human anatomy', Med Phys., 21, 299-302 (1994)
7 J.F. Briesmeister, 'MCNP - A General Monte Carlo Code N-Particle Transport Code, Version 4C', LA-13709-M (2000)
8 International Commission on Radiological Protection,Basic Anatomical and Physiological Data for Use in Radiological Protection: The Skeleton, ICRP Publication 89, Pergamon Press (2003)
9 M. Zankl, U. Fill, N. Petoussi-Henss, and D. Regulla, 'Organ dose conversion coefficients for external photon irradiation of male and female voxel models', Pitys. Med Biol. 47, 2367-2385 (2002)
10 International Commission on Radiological Protection, 1990 Recommendation of the International Commission on Radiological Protection, ICRP Publication 60, Pergamon Press (1990)
11 R.J. Staton, FD. Pazik, J.C. Nipper, J.L. Williams, and WE. Bolch, 'A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology', Phys. Med. Biol., 48, 805-820 (2003)   DOI   ScienceOn
12 M. Zankl, U. Fill, N. Petoussi-Henss, and D. Regulla, 'Organ dose conversion coefficients for external Photon irradiation of male and female voxel models', Phys. Med. Biol., 47, 2367-2385 (2002)   DOI   ScienceOn
13 K. Saito, A. Wittmann, S. Koga, Y. Ida, T. Kamei, J. Funabiki, and M. Zankl, 'Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system', Radiat. Environ Biopltys. 40, 69-76 (2001)
14 이재기, 김종경, 정운관, 장재권, 김현기, 한치영, 비균질 감마 방사선장에 대한 유효선량 평가법의 연구, 과제번호97-중-8/중간보고서 , 한양대학교 (1998)
15 T.C. Chao, A. Bozkurt, and X.G. Xu, 'Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to lOMeV', Health Phys. 81(2), 163-183 (2001)
16 M. Zankl and A. Wittmann, 'The adult male voxel model 'Golem' segmented from whole-body CT patient data', Radiat. Environ Biophys., 40, 153-162 (2001)   DOI