• Title/Summary/Keyword: organ distribution

Search Result 256, Processing Time 0.026 seconds

A New Method For Measuring Acupoint Pigmentation After Cupping Using Cross Polarization (교차편광 촬영술(Cross Polarization Photographic Technique)를 이용한 부항요법의 배수혈 피부 색소 침착 변화 측정 평가)

  • Kim, Soo-Byeong;Jung, Byungjo;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.252-263
    • /
    • 2013
  • Objectives : Skin color deformation by cupping has been widely used as a diagnostic parameter in Traditional Korean Medicine(TKM). Skin color deformation such as ecchymoses and purpura is induced by local vacuum in a suction cup. Since existing studies have relied on a visual diagnostic method, there is a need to use the quantitative measurement method. Methods : We conducted an analysis of cross-polarization photographic images to assess the changes in skin color deformation. The skin color variation was analyzed using $L^*a^*b^*$ space and the skin erythema index(E.I.). The meridian theory in TKM indicates that the condition of primary internal organs is closely related to the skin color deformation at special acupoints. Before conducting these studies, it is necessary to evaluate whether or not skin color deformation is influenced by muscle condition. Hence, we applied cupping at BL13, BL15, BL18, BL20 and BL23 at Bladder Meridian(BL) and measured blood lactate at every acupoint. Results : We confirmed the high system measurement accuracy, and observed the diverse skin color deformations. Moreover, we confirmed that the $L^*$, $a^*$ and E.I. had not changed after 40 minutes(p>0.05). The distribution of blood lactate levels at each part was observed differently. Blood lactate level and skin color deformation at each part was independent of each other. Conclusions : The negative pressure produced by the suction cup induces a reduction in the volumetric fraction of melanosomes and subsequent reduction in epidermal thickness. The relationship between variations of tissue and skin properties and skin color deformation degree must be investigated prior to considering the relationship between internal organ dysfunction and skin color deformation.

Pelvic microbial flora in the users versus the nonusers of intrauterine device determined by laparoscopic method (복강경을 이용한 자궁내장치 사용자의 복강세균학적 연구)

  • Hahn, Won-Bo;Kwak, Hyun-Mo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.11 no.1
    • /
    • pp.17-32
    • /
    • 1984
  • There are numerous reports on the relative risk of pelvic inflammatory disease among the users versus the nonusers of intrauterine device. Reported relative risk varied from no difference between the two groups to 3-9 fold increase in the users. In an attempt to define this relative risk of pelvic inflammatory disease and related microorganisms ,pelvic organ observation and bacteriological study were done through laparoscopy. Specimens for microbiologic culture were obtained simultaneously from the fallopian tubes via laparoscopy and from the endocervix via regular pelvic examination method. The study population was consisted of 30 I.U.D.users and 35 J.U.D.nonusers who visited the Yonsei University Severance Hospital and the Sung-Ga Hospital for laparoscopic sterilization. The results obtained were as follows: 1. There was no difference in age distribution, economic status and numbers of parity and abortion between I.U.D. users and I.U.D. nonusers. 2. The pelvic inflammatory findings were noted on laparoscopy in 2 cases of I.U.D. users, with an incidence of 6.6%. And no pelvic inflammatory finding was noted in any of the nonusers,but this difference was not statistically significant (p>0.005). 3. All the bacteriologic culture of the specimens from the fallopian tubes of both groups yielded negative results. 4. The bacteriologic culture of the spec imens f rom the endocervix revealed more frequent isolation of possible pathogen such as Hem ophilus ,alpha-Streptococcus ,Corynebacteria, Bacteroides in the I.U.D.users than in the nonusers.But,this difference was also not statistically significant (p>0.005).

  • PDF

Analysis of Productivity in Rice Plant -IV. Sink-filling rate and sink-source relation (벼의 생산력 분석(分析) -IV. 수기(受器)의 충전속도(充塡速度)와 수기(受器)-급기(給器) 관계(關係))

  • Park, Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.2
    • /
    • pp.95-105
    • /
    • 1973
  • Sink (grain)-filling rates of IR667 line (Suwon 213 and 214) and local leading varieties (Jinheung and Paldal) were investigated in relation to sink-source ratio, sink-source distance, forms of photosynthates, and weather factors. The results are as follows. 1. IR667 line have higher maximum filling rate (g. grain/day. ear) and shorter duration to reach maximum filling rate than local varieties. The curve pattern of sink-filling rate was high and steep type in IR667 line and low and broad type in local varieties. 2. Weather factors seem to give little effect on the curve pattern of sink-filling rate. 3. The functional sink-source distance (actual sink-source distance multiplied by the contribution rate of leaf for grain production) was shorter in upper leaves (flag and 2nd leaf) for IR667 line, the upper leaf-dependent type in grain production, and was longer in lower leaves (3rd and 4th) for local varieties, the lower leaf-dependent type. Specially short first internode from top may contribute to the upper leaf depencency of IR667 line. 4. According to free sugar-starch ratio (sugar/starch) in the culm and leaf sheath IR667 line could be classified as the high sugar type and the local varieties as the high starch type. The ratio of transportable form (sugar) to non transportable photosynthate (starch) seems to relate with sink-filling rate. And high sugar type is expected to have higher efficiency for grain production in view of energy balance. 5. A hypothesis that the higher in the uniformity within the series of productive structure the more efficient in grain production is proposed and discussed in relation to productivity. 6. According to the pattern of percent nutrient retention of each leaf blade IR667 showed the central retention type and Jinheung showed the apical retention type and each retention type appears to be a cause of each canopy conservation pattern. 7. From the content and percent distribution of nutrient in various organ IR667 could be classified as the leaf sheath dominant type and Jinheung as the leaf blade dominant type. 8. The fact that the greater the percent translocation of nutrient into grain the greater the percent nutrient retention in leaf blade was held between nitrogen and phosphorus within a variety and between varieties within a nutrient (N, P or K).

  • PDF

Histopathological and Serological Observations on Experimental Anisakiasis of Rabbits (실험적 토끼 아니사키스증에서의 조직학적 병변과 혈청 항체가의 경시적 변동 양상)

  • 홍성태;이손형
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.168-180
    • /
    • 1987
  • This study was performed to observe histopathological changes and serological reactions in chronic anisakiasis of rabbits. Each rabbit was infected per os with 30 larvae of Anisakis type I. Their sera were collected chronologically and the rabbits were killed for histopathological examination, 3, 13, 20, 30, 60, 90 and 150 days after the infection. The results were summarized as below. 1. Most of the larvae were recovered from the stomach, but a few from the omentum, intestine, mesentery and abdominal wall. The recovery rates and distribution of worms by organ were not differed by duration of infection. 2. Histologically the lesion was abscess type on 13 days, i.e., the dead worms were surrounded by fibrinous exudate, histiocytes and thick zone of numerous inflammatory cells. After 30 days, histiocytes were found to invade the worms and the lesion was changing into abscessgranulomatous type. Also a calcified worm was found on the 30th day. After then the worms were observed to be dissolved slowly until 90 days. On 150 day, only one calcified worm was observed. 3. The levels of serum IgG antibody by ELISA reached their maximum 30 days after the infection. After then, it decreased slowly until 150 days after the infection. Above serological and histopathological findings indicated that antigenic stimulation from degenerating Anisakis larvae was the greatest during the first 30 days after infection. This period was corresponding with the beginning of worm resolution or calcification. Serologic test by ELISA would be a valuable tool for confirming chronic anisakiasis.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF