• Title/Summary/Keyword: optimum voltage

Search Result 620, Processing Time 0.024 seconds

An optimal design guideline for voltage drop of DC distribution system with batteries (예비축전지를 갖는 배전계통 전압강하의 비용최적 설계)

  • Cho, Il-Kwon;Kim, Marn-Go
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.400-402
    • /
    • 1994
  • The voltage drop in distribution path of battery-reserved DC power system can affect the total of battery, cable and electricity costs. To determine an optimum voltage drop in distribution path for minimizing the total cost, battery, cable and electricity costs are represented as a function of the voltage drop, respectively, and are summed up to the total cost. An optimum voltage drop is selected as the value giving the minimum total cost. In this paper, a design technique of optimum voltage drop in distribution path of DC power system is proposed to minimize the total of battery, cable and electricity costs. The design procedure is described and design curve for selecting optimum voltage drop is also presented as a function of distribution distance.

  • PDF

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier (3상 위상제어 정류기를 위한 DVR의 반응시간 최적화)

  • Park, Chul-Woo;Joung, Sookyoung;Ryu, Jee-Youl;Lee, Dae-Seup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.

A novel approach for optimal DG allocation in distribution network for minimizing voltage sag

  • Hashemian, Pejman;Nematollahi, Amin Foroughi;Vahidi, Behrooz
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.55-73
    • /
    • 2019
  • The cost incurred by voltage sag effect in power networks has always been of important concern for discussions. Due to the environmental constraints, fossil fuel shortage crisis and low efficiency of conventional power plants, decentralized generation and renewable based DG have become trends in recent decades; because DGs can reduce the voltage sag effect in distribution networks noticeably; therefore, optimum allocation of DGs in order to maximize their effectiveness is highly important in order to maximize their effectiveness. In this paper, a new method is proposed for calculating the cost incurred by voltage sag effect in power networks. Thus, a new objective function is provided that comprehends technical standards as minimization of the cost incurred by voltage sag effect, active power losses and economic criterion as the installation and maintenance costs of DGs. Considering operational constraints of the system, the optimum allocation of DGs is a constrained optimization problem in which Lightning Attachment procedure optimization (LAPO) is used to resolve it and is the optimum number, size and location of DGs are determined in IEEE 33 bus test system and IEEE 34 bus test system. The results show that optimum allocation of DGs not only reduces the cost incurred by voltage sag effect, but also improves the other characteristics of the system.

A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train (한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구)

  • 이상우;김근웅;윤종학;한성수
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

Voltage Angle Control of an IPMSM for Electric Vehicle Drives (전기자동차 구동을 위한 IPMSM의 전압각 제어)

  • Ko, Tae-Hoon;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.397-403
    • /
    • 2017
  • This paper studies the voltage angle control of interior permanent magnet synchronous motors (IPMSMs). For voltage angle control, the optimum voltage angle trajectory according to the operating speed is researched while the voltage and current limit conditions are considered. Through research, two different optimum voltage angle trajectories that depend on the design of IPMSMs were found. The IPMSM drive based on a voltage angle control that follows such trajectory is proposed. Unlike the conventional voltage angle control method, which is applied only in the flux-weakening region, the proposed voltage angle control can be implemented in all operation ranges from low to high speed. The proposed method is verified by experiments using a DSC controller for 800 W IPMSM.

On the Optimum Linear Voltage Regulator of a Self-excited DC Shunt Generator (직류자여자분권발전기의 최적선형전압조정기에 관한 연구)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.11-16
    • /
    • 1973
  • This paper presents an optimum control of the field resistance for the self-excited DC shunt generator to keep a constant terminal voltage in case of the load change or the torque variation in the system. The non-linearity of the system is linearized by applying the small signal technique and the linearized equation is solved by the maximum principle with the digital computer. The optimal control value of the field resistance for the step error of the generator output voltage is obtained and the transient voltage characteristics in the system are investigated.

  • PDF

Output Voltage Increment of a PWM Inverter by The Harmonic Injection Method (고조파 주입에 의한 PWM 인버터의 출력전압 증대)

  • 박민호;홍순찬;정근진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.362-369
    • /
    • 1989
  • A method to increase the output voltage of the PWM inverter within linear range is considered. A new modulation wave is used, which is made by injecting the third harmonic wave into the sinusoidal wave. The optimum region for improving the output voltage keeping the linear control characteristic is obtained by digital simulation. Furthermore, the distortion factor in the optimum region is less than that calculated when the maximum output voltage can be obtained in the sinusoidal PWM inverter.

  • PDF

Output Voltage Ripple Analysis of Quantum Series Resonant Converter (QSRC의 출력전압맥동해석)

  • 임성운;권우현;조규형
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.3
    • /
    • pp.141-149
    • /
    • 1994
  • In this paper, we could find optimum quantum sequence(OQS) to minimize the output ripple voltage of the quantum series resonant converter(QSRC). This sequence control is so general that it is irrelevant to the voltage gain so far as it is operating in the continuous conduction mode(CCM). Further more the dynamic range of QSRC is much extended by the optimum quantum sequence control(OQSC). Througuout the time-domain analysis, the solution of steady state and the boundary condition between continuous and discontinuous mode is QSRC is obtained. This feature is verified by simulations and experiments with good agreements.

  • PDF

The Effect of Substrate Bias Voltage during the Formation of BN film by R. F. Sputtering Method (RF 스퍼터링법에 의한 BN박막 증착시 기판 바이어스전압의 영향에 관한 연구)

  • 이은국;김도훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 1996
  • In this work BN thin films were deposited on Si substrate by R. F. sputtering method at $200^{\circ}C$ and in Ar + $N_2$ mixed gas atmosphere. In order to investigate the effect of ion bombardment on substrate for c-BN bonding, substrate bias voltage was applied. The optimum substrate bias voltage for c-BN bonding was determined by FTIR analysis on specimens which were deposited with various bias voltages. Then BN thin film was deposited with this optimum condition and its phase, morphology, chemical composition, and refractive index were compared with those of BN film which was deposited without bias voltage. FTIR results showed that BN films deposited with substrate bias voltage were composed of mixed phases of c-BN and h-BN, while those deposited without bias voltage were h-BN only. When pure Ar gas was used for sputtering gas, BN films were delaminated easily from substrate in air, while when 10% $N_2$ gas was added to the sputtering gas, although c-BN specific infrared peak was reduced, delamination did not occur. GXRD and TEM results showed that BN films were amorphous phases regardless of substrate bias voltage, and AES results showed that the chemical compositions of B/N were about 1.7~1.8. The refractive index of BN film deposited with bias voltage was higher than that without bias voltage. The reason is believed to be the existence of c-BN bonding in BN film and the higher density of film that deposited with the substrate bias voltage.

  • PDF