• Title/Summary/Keyword: optimum measurement

Search Result 703, Processing Time 0.022 seconds

Measurement of Na intake in Korean Adult Females (우리나라 성인 여성의 Na 섭취량 측정방법의 모색)

  • 김영선
    • Journal of Nutrition and Health
    • /
    • v.20 no.5
    • /
    • pp.341-349
    • /
    • 1987
  • Dietary intakes of na include both the amount present in food materials (nondiscretionary Na intake) and the amount added during cooking and eating to increase salty taste and flavor (discretionary Na intake). In the present study, total Na intake was measured by duplicate food sample collected from each subject for 1 day, nondiscretionary Na intake was calculated by dietary intake record, optimum gustation of salt was measured of from pooled 3-day urine collection in healthy female college students, to measure Na intake more accurately and to find suitable method to estimate total Na intake. Mean values of total, discretionary and mondiscretionary Na intakes were 169.6 mEq, 46.2mEq, and 123.4mEq. respectively. Mean 24-hour urinary Na excretion was 137.9mEq., which was about 84.5% of total intake. Subjects with optimum gustation of salt equal to or higher than 0.5% had significantly higher total Na intake and urinary Na excretion compared to subjects with optimum gustation of salt lower than 5%. Total Na intake of subjects were significantly correlated with optimum gustation of salt, non-discretionary and discretionary Na intakes, and urinary Na excretion. Multiple regression analysis showed that the best estimate of total Na intake is obtained when both optimum gustation of salt and non-discredinary Na intake were used as independent variables (r=.7071). Among the equations using one independent variable, regression, equation with urinary Na excretion provides the best approximation (r=.6627) of total Na intake.

  • PDF

Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method (생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정)

  • Kim, Keo-Sik;Lee, Sang-Ok;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

Neutron dosimetry with a pair of TLDs for the Elekta Precise medical linac and the evaluation of optimum moderator thickness for the conversion of fast to thermal neutrons

  • Marziyeh Behmadi;Sara Mohammadi;Mohammad Ehsan Ravari;Aghil Mohammadi;Mahdy Ebrahimi Loushab;Mohammad Taghi Bahreyni Toossi;Mitra Ghergherehchi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.753-761
    • /
    • 2024
  • Introduction: In this study, TLD 600 and TLD 700 pairs were used to measure the neutron dose of Elekta Precise medical linac. To this end, the optimum moderate thickness for the conversion of fast to thermal neutrons were evaluated. Materials and methods: 241Am-Be and 252Cf sources were simulated to calculate the optimum thicknesses of the moderator for the conversion of maximum fast neutrons (FN) into thermal neutrons (TN). Pair TLDs were used to measure F&TN doses for three different field sizes at four depths of the medical linac. Results: The maximum thickness of the moderator was optimized at 6 cm. The measurement results demonstrated that the TN dose increased with the expansion of field size and depth. The FN dose, which was converted TN, exhibits behaviors comparable to the TN due to its nature. Conclusion: This study presents the optimum thickness for the moderator to convert FN into TN and measure F&TN using TLDs.

On the Transmission Loss Measurement System (전달손실계수 측정 시스템에 대하여)

  • Ryu, Yun-Seon;Kim, Yoon-Seok;Callec, Philippe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.166-171
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

On the Transmission Loss Measurement System (전달손실계수 측정시스템에 대하여)

  • Yunseon RYU;Yoon-Seok KIM;Philippe CALLEC
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.323.1-323
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system usiong 4-microphone impedance tube is proposed, based on the idea calculating the full transger matrix of the acoustical sample to test. The theoretical backgroung and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Acoustic Transmission Loss Measurement of the Exhaust System with TL Tube (TL 튜브를 이용한 소음기의 음향 전달 손실 계측법)

  • 류윤선;김윤석;이성홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.770-773
    • /
    • 2004
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the acoustic transmission loss measurement system using 4-microphone TL tube is applied to the exhaust system, which is one of the most important acoustic control parameters in a car, based on the idea calculating the full transfer matrix. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

On the Transmission Loss Measurement System(Part II) (전달손실계수 측정 시스템에 대하여(Part II))

  • 김윤석;류윤선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.658-661
    • /
    • 2003
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Design of Passive-Type Radar Reflector

  • Yim, Jeong-Bin;Kim, Woo-Suk
    • Journal of Navigation and Port Research
    • /
    • v.27 no.3
    • /
    • pp.267-272
    • /
    • 2003
  • This paper describes design method of Passive-type Radar Reflector (PRR) which is to provide the requirement of newly revised 2000 SOLAS regulations on the Radar Reflector. The main target of this work is to find the optimum shape of a radar target having large Radar Cross Section (RCS). Through the RCS analysis based on the theoretical approach, two kinds of PRR models, RRR-F model for use in fisheries and PRR-S model for use in small sized ship, are designed and discussed their RCS performance. RCS measurement tests for the various sized samples are carried out in an anechoic chamber. As evaluation results it was clearly shown that the conventional sphere-type shows optimum shape in case of PRR-S, while the cylinder-type which consists of large sized corner clusters or zig-zag flat plats gives best performance in case of PRR-F.

The Study on Optimum Ventilation System during Long Tunnel Construction (굴착중인 장대터널 내 최적의 환기시스템에 관한 연구)

  • Lim, Han-Uk;Oh, Byung-Hwa
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.3-15
    • /
    • 2006
  • To determine the optimum ventilation systems during long tunnel excavation, the velocity vector profile and the contaminant's distribution at working place are studied using 2-D, 3-D numerical analysis. The main results can be summarized as follow; In case of long tunnels, blower-exhaust-mixture types which enable to use soft blast ducts is most appropriate in terms of ventilation and economical efficiency. Of the same ventilation types, ventilation efficiency has a difference according to blast ducts and the distance between fan and working place. The 3-D numerical result shows that arranging blower and exhaust ducts in the right and left corners of the tunnel respectively is effective to discharge contaminant. The result of the real measurement shows that CO concentration can be reduced to below 50 ppm, which is regulation value, as 16-minutes fan operation goes on.

  • PDF

A Study of Fatigue Strength Improvement for Cr-Mo Steel in Long Term service (장기간 사용한 Cr-Mo강의 피로강도향상 방법에 관한 연구)

  • 진영준
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.27-35
    • /
    • 2001
  • For the purpose of healing the degradation part, $CO_2$ laser beam was irradiated with different irradiation condition (porer, diameter, velocity and beam type) to find out optimum irradiation condition. The test series of hardness, residual stress measurement, and fatigue were carried out after the irradiation. Experimental results show that micro-hardness values on the surface of the irradiated specimens m approximately 2.5 times higher than those of un-irradiated ones. Fatigue tests show that the fatigue life was improved by the compressive residual stress after laser beam irradiation. However, some specimens with different conditions show the shorter fatigue life. It means that laser beam irradiation with optimum irradiation condition and optimum absorb energy, Q can improve the fatigue strength.

  • PDF