• Title/Summary/Keyword: optimum area

검색결과 1,732건 처리시간 0.026초

염료감응형 태양전지의 대면적화를 위한 최적 구조 연구 (A Study on The Optimum Structure of Dye-sensitized Solar Cell for Upscaling)

  • 서현웅;김미정;홍지태;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1295-1296
    • /
    • 2007
  • A lot of researches about dye-sensitized solar cell (DSC) are recently being conducted. Because DSC has several advantages to pass the limits of silicon solar cells such as a low manufacturing expense, a simple manufacturing process and its transparency. But most researches on DSC are still conducted about the unit cell and laboratory-centered. That is, present researches on DSC are not practical. Therefore, researches about large area cells and modules have to be prerequisites for DSC to have the practicality. Characteristics of large area DSC are so different from those of small area DSC in aspect of fill factor and efficiency. In this study, we made an experiment on finding suitable size of DSC that has the most effective power according to the variation of active area. In detail, the experiment was conducted about the optimum ratio of length to width and we introduced the ratio of active area to non-active area to find the active area which has the best output. Because small DSC doesn‘t have the best output in comparison with total area of cell although the smaller DSC has the better efficiency. As a result, we achieved the optimum ratio of length to width of 8:3 and active area of $8cm^2$ as the optimum size for upscaling DSC.

  • PDF

5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석 (Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

광량 및 광질이 고려인삼의 생육과 품질에 미치는 영향 II. 광량과 재식밀도와의 관계 (Effects of Light Intensity and Quality on the Growth and Quality of Korean Ginseng (Panax ginseng C.A. Meyer) II. Relationship between Light Intensity and Planting Density)

  • 천성기;목성균;이성식
    • Journal of Ginseng Research
    • /
    • 제15권1호
    • /
    • pp.31-35
    • /
    • 1991
  • In order to know the optimum planting density under shading structures at different light intensity, We investigated the growth status, distribution of ginseng leaf area, correlation between planting density and root weight per plant and yield, correlation between leaf area index and root weight per plant and yield. According to the increase of planting density the leaf area per plant was decreased, but leaf area index (L.A.I) was increased. Ginseng leaf population at different lines under common straw shading were distributed mainly in frost lines but polyethylene net shading at 10fo light intensity were distributed equally in all lines. Optimum planting density in common straw shading at 5% light intensity was 55 plant per tan (90 cmX180 cm) and polyethylene net shading 81 10% light intensity was 60 plant per tan, in consideration of root weight and yield. Optimum leaf area index was 2.4 under common straw shading at 5% light intensity but was 2.7 under polyethylene net shading at 10% light intensity.

  • PDF

유로코드를 이용한 주름웨브보의 최적설계 연구 (A Study on Optimum design of Corrugated web girder using Eurocode)

  • 손수덕;유미나;이승재
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.47-56
    • /
    • 2012
  • This paper describes the structural design and optimization of sinusoidally corrugated web girder by using EUROCODE (EN 1993-1-5). The optimum design methodology and characteristics of the optimal cross-section are discussed. We investigate a shear buckling and the concerned standards for corrugated web and explain the equations to obtain a critical stress according to buckling type. In order to perform optimization, we consider an objective function as minimum weight of the girder and use the constraint functions as slenderness ratio and stresses of flanges as well as corrugated web and deflection. Genetic Algorithm is adopted to search a global optimum solution for this mathematical model. For numerical example, the clamped girder under the concentrated load is considered, while the optimum cross-sectional area and design variables are analyzed. From the results of the adopted example, the optimum design program of the sinusoidally corrugated web girder is able to find the suitable solution which satisfied a condition subject to constraint functions. The optimum design shows the tendency to decrease the cross-sectional area with the yielding strength increase and increase the areas with load increase. Moreover, the corrugated web thickness shows a stable increase concerning the load.

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

Automated design of optimum longitudinal reinforcement for flexural and axial loading

  • Tomas, Antonio;Alarcon, Antonio
    • Computers and Concrete
    • /
    • 제10권2호
    • /
    • pp.149-171
    • /
    • 2012
  • The problem of a concrete cross section under flexural and axial loading is indeterminate due to the existence of more unknowns than equations. Among the infinite solutions, it is possible to find the optimum, which is that of minimum reinforcement that satisfies certain design constraints (section ductility, minimum reinforcement area, etc.). This article proposes the automation of the optimum reinforcement calculation under any combination of flexural and axial loading. The procedure has been implemented in a program code that is attached in the Appendix. Conventional-strength or high-strength concrete may be chosen, minimum reinforcement area may be considered (it being possible to choose between the standards ACI 318 or Eurocode 2), and the neutral axis depth may be constrained in order to guarantee a certain sectional ductility. Some numerical examples are presented, drawing comparisons between the results obtained by ACI 318, EC 2 and the conventional method.

회전매체를 가진 완전혼합활성슬러지 공법을 이용한 온천지구 하수의 재이용 (Reuse of the sewage from sea area using the Submerged Moving Media Complete Mixing Activated Sludge (SMMCMAS))

  • 김홍태;김학석
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.69-74
    • /
    • 2002
  • This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.

태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究) (A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System)

  • 이영수;이기우
    • 태양에너지
    • /
    • 제6권1호
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

중.소도시 하천의 친환경적 활용 잠재력 평가에 관한 연구 -전남 순천시 하천을 사례로- (A Study on the Evaluation of Pro-environmental Potential of Streams in Sunchon City)

  • 정정채;이상석
    • 한국조경학회지
    • /
    • 제26권1호
    • /
    • pp.96-112
    • /
    • 1998
  • This study aims to evaluate the potential of pro-environmental application(PEP) in streams conceptualized ecological conservation and recreational use to be in harmony with. The main content of research are to clarify the PEP, to establish the evaluation model, and to evaluate 3 streams(Dongchon, Seokhyunchon, Okchon) in Sunchon city. Researchers introduced 12 evaluation items(water quality, water quantity, vegetation-water area, vegetation conservation, streamscape, neighborhood landscape, stream width, optimum area, nearby landuse, facility in stream, distance from user, obstacle to acces) by 5 scales to evaluate the characteristics of natural and artificial factors in stream area and nearby area. Also to decide the weight of items, researchers surveyed the opinion of 22 landscape architects experienced stream-plan through delphi method. Lastly the pro-environmental potential on streams were calculated by the ecological potential and recreational potential indices to be standardized and indicidual sections in streams were divided 5 grades on the basis of PEP. The result of this study are as follows; 1) The evaluation model of PEP was constructed by 4 steps, such as the decision of weight, the measurement of scale, the calculation of potential indices, the gradation of individual sections in streams. 2) The ecological potential were highly influenced by natural factor such as water quality, vegetation conservation, vegetation-water area, but on the other hand the recreational potential were influenced by optimum area, distance from user, water quantity, obstacle to access. 3) The factors such as vegetation conservation, optimum area, nearby landuse, distance from user were function as discernment factors to evaluate relatively ecological and recreational potential. and water quality, water quantity, vegetation -water area, neighborhood landscape were acted as important items to decide PEP.

  • PDF

Root Yields and Saikosaponin Contents Depending on Planting Time and Cultivated Regions of Bupleurum falcatum L.

  • Kim, Choon-Shik;Seong, Jae-Duck;Park, Chung-Heon;Park, Chun-Gun;Cho, Yang-Hee;Kwak, Jun-Soo
    • 한국약용작물학회지
    • /
    • 제13권5호
    • /
    • pp.298-302
    • /
    • 2005
  • In order to decide the optimum planting time for Bupleurum falcatum L. which is grown widely in Korea, some experiments were carried out in different regions such as mid-north area (Gangwon-do, Gyeonggi-do and Chungcheongnamdo), mid-south area (Jeollanam-do, Jeollabuk-do, Gyeongsangnam-do and Gyeongsangbuk-do). The mid-south area had the highest total saikosaponin contents of 1.001, which is the medicinal ingredients of Bupleurum falcatum L., in accordance with the different Bupleurum falcatum L. regions. Also this area has the highest extract contents of 24.3%. Average dry root yields in mid-north area (Gangwon-do) were $450{\sim}460$ kg/ha at planting time of March 20th to March 30th, 500 kg/ha at the time of March 30th to April 10th, and $470{\sim}480$ kg/ha at the time of March 10th to March 20th in Chungcheongnam-do. The optimum planting time in the mid-south area (Jeollabuk-do) was March 10th to March 30th with the average dry root yield of $490{\sim}550$ kg/ha. Average dry root yield in Euiseong, Gyeongsangbuk-do area was 470 kg/ha, and the optimum planting time was April 10th, which suggested that the yield increased as the planting time was delayed. At Jeju-do, the volcanic soil of farsouthern area, average dry root yield was 510 kg/ha at the time of March 10th, but the yield from non-volcanic soil was lower than from volcanic soil, which had a dry root yield of 470 kg/ha.