• Title/Summary/Keyword: optimal wavelength

Search Result 269, Processing Time 0.026 seconds

Influence of $TiO_2$ Concentrations and Irradiation Lights on the Photocatalytic Reaction for Inhibiting Growth of Streptococcus mutans ($TiO_2$ 농도 및 여기광에 따른 광촉매 반응이 Streptococcus mutans의 생장에 미치는 영향)

  • Kang, Si-Mook;Lee, Hae-Na;Kim, Hee-Eun;Kim, Baek-Il
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.319-324
    • /
    • 2014
  • The aim of this study was to evaluate influences of titanium dioxide ($TiO_2$) concentrations and irradiation times on growth of Streptococcus mutans when irradiated by visible light (405 nm wavelength) and by ultraviolet light (254 nm wavelength). To find the optimal antibacterial concentration of $TiO_2$, 0.01, 0.1, 1.0, and 10.0 mg/ml $TiO_2$ suspension was prepared with sterilized distilled water. S. mutans cultured media was added to $TiO_2$ solution to set the final cell count to $10^4CFU/ml$. The photocatalytic reaction was induced by irradiating 254 nm and 405 nm lights for 10 minutes. To compare the bactericidal activities according to irradiation times, all photocatalytic reaction was carried out with 0.1 mg/ml $TiO_2$ for 0, 10, 20, 30, and 40 minutes with both lights. After the photocatalytic reaction, $100{\mu}m$ of the reaction mixture was immediately plated on brain heart infusion agar. These plates were placed at 5% $CO_2$, $37^{\circ}C$, for 24 hours and the bacterial colonies were counted. All experiments were performed in quintuplicate. One-way ANOVA was used to determine whether there were any significant differences between the $TiO_2$ concentrations or the irradiation times. The most effective concentration of $TiO_2$ for its photocatalytic bactericidal effect on S. mutans was 0.1 mg/ml when irradiated with 254 nm and 405 nm lights. The longer the irradiation time, the bigger the bactericidal effect for both wavelengths. Over 99% of bacteria in the inoculum were killed after irradiation with 254 nm for 20 minutes and with 405 nm for 40 minutes. In conclusion, a photocatalytic reaction of $TiO_2$ induced by visible light of 405 nm constitutes the bactericidal effect on S. mutans.

The Active Noise Control in Harmonic Enclosed Sound Fields (I) Computer Simulation (조화가진된 밀폐계 음장에서의 능동소음제어 (I) 컴퓨터 시물레이션)

  • Oh, Jae-Eung;Lee, Tae-Yeon;Kim, Heung-Seob;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1054-1065
    • /
    • 1993
  • A computer simulation is performed on the effectiveness of the active minimization of harmonically excited enclosed sound fields for producing global reduction in the amplitude of the pressure fluctuations. In this study for the appreciable reductions in total time averaged acoustic potential energy, $E_{pp}$, the transducer location strategies for three dimensional active noise control is presented based on a state space modal which approximates the closed acoustic field.In this study, the above theoretical basis is used to investigate the application of active control to sound fields of low modal density. By the used of room-like 3-dimensional rectangular enclosure it is demonstrated that the reductions in $E_{pp}$ can be achieved by using a single secondary source, provided that the source is placed within the half a wavelength from the primary source and placed away from nodal line of the sound field. Concerning the reductions in $E_{pp}$ by minimzing the pressure in sound fields by the use of 3-dimensional rectangular enclosure, the effects of the number of sensors and the locations of these sensors are investigated. When a few modes dominate the response it is found that if only a limited number of sensors are located away from nodal line and located at the pressure maxima of the sound field such as at each corner of a rectangular enclosure.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Sclerotic Dentin (Nd:YAG레이저조사가 경화상아질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Kim, Moon-Hyeon;Shin, Keum-Back
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.4
    • /
    • pp.397-410
    • /
    • 1999
  • In order to obtain the basic data concerning the optimal parameters in using Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity, the author prepared 3 sections of sound dentin and 10 sections of sclerotic dentin with thickness of $0.5mm{\pm}0.1mm$ from human extracted teeth of anteriors and premolars, and applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, pulse duration $120{\mu}sec$, fiber diameter $320{\mu}m$) to surfaces of sound and sclerotic dentin sections for 1 second with contact/unidirectional moving mode of the fiber under speed of 3mm~4mm/sec and parameters of 0.5W/10Hz, 1.0W/10Hz, 1.5W/10Hz, 2.0W/10Hz: $62J/cm^2$, $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. The author comparatively evaluated the characteristics of ultrastructural changes on surfaces of sound and sclerotic dentin sections irradiated by the pulsed Nd:YAG laser using the scanning electron microscopy. A fairly ill-defined bordered surface of partially closed and melted dentinal tubules can be seen on the scanning electron microscopic feature of the sound dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sound dentin surface extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. While, a fairly well-defined bordered surface of partially closed and melted dentinal tubules with thickened peritubular dentin can be seen on the scanning electron microscopic feature of the sclerotic dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sclerotic dentin surface of a fairly rough, shallow depression with many cracks, thickened peritubular dentin and structureless dentinal tubules extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$ compared to those of sound dentin surface irradiated by the pulsed Nd:YAG laser under the same parameters. Therefore, it is recommended that the pulsed Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity should be applied with the less energy density than $62J/cm^2$ on the sound dentin surface, and its energy density on the partially sclerotic dentin surface should be lower than that on the sound dentin surface to preserve tooth from unnecessary excessive structural destruction.

  • PDF

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Application of Residual Statics to Land Seismic Data: traveltime decomposition vs stack-power maximization (육상 탄성파자료에 대한 나머지 정적보정의 효과: 주행시간 분해기법과 겹쌓기제곱 최대화기법)

  • Sa, Jinhyeon;Woo, Juhwan;Rhee, Chulwoo;Kim, Jisoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • Two representative residual static methods of traveltime decomposition and stack-power maximization are discussed in terms of application to land seismic data. For the model data with synthetic shot/receiver statics (time shift) applied and random noises added, continuities of reflection event are much improved by stack-power maximization method, resulting the derived time-shifts approximately equal to the synthetic statics. Optimal parameters (maximum allowable shift, correlation window, iteration number) for residual statics are effectively chosen with diagnostic displays of CSP (common shot point) stack and CRP (common receiver point) stack as well as CMP gather. In addition to removal of long-wavelength time shift by refraction statics, prior to residual statics, processing steps of f-k filter, predictive deconvolution and time variant spectral whitening are employed to attenuate noises and thereby to minimize the error during the correlation process. The reflectors including horizontal layer of reservoir are more clearly shown in the variable-density section through repicking the velocities after residual statics and inverse NMO correction.

Deep Learning Based Floating Macroalgae Classification Using Gaofen-1 WFV Images (Gaofen-1 WFV 영상을 이용한 딥러닝 기반 대형 부유조류 분류)

  • Kim, Euihyun;Kim, Keunyong;Kim, Soo Mee;Cui, Tingwei;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.293-307
    • /
    • 2020
  • Every year, the floating macroalgae, green and golden tide, are massively detected at the Yellow Sea and East China Sea. After influx of them to the aquaculture facility or beach, it occurs enormous economic losses to remove them. Currently, remote sensing is used effectively to detect the floating macroalgae flowed into the coast. But it has difficulties to detect the floating macroalgae exactly because of the wavelength overlapped with other targets in the ocean. Also, it is difficult to distinguish between green and golden tide because they have similar spectral characteristics. Therefore, we tried to distinguish between green and golden tide applying the Deep learning method to the satellite images. To determine the network, the optimal training conditions were searched to train the AlexNet. Also, Gaofen-1 WFV images were used as a dataset to train and validate the network. Under these conditions, the network was determined after training, and used to confirm the test data. As a result, the accuracy of test data is 88.89%, and it can be possible to distinguish between green and golden tide with precision of 66.67% and 100%, respectively. It is interpreted that the AlexNet can be pick up on the subtle differences between green and golden tide. Through this study, it is expected that the green and golden tide can be effectively classified from various objects in the ocean and distinguished each other.

Improvement of System Performance Through Concentrated RDPS in WDM Transmission Links with Dispersion Management (분산 제어가 적용된 WDM 전송 링크에서 집중 RDPS를 통한 시스템 성능 개선)

  • Lee, Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.971-980
    • /
    • 2013
  • System performance improvement through the concentrated residual dispersion per span (RDPS) in special transmission fiber spans in optical transmission links with dispersion management (DM) for wavelength division multiplexed (WDM) transmission is investigated through the comparison with the performance in optical transmission links with uniform RDPS in every fiber spans. It is confirmed that, in optical links with RDPS of 0 ps/nm uniformly distributed in the rest fiber spans, if RDPS of 300 ps/nm and 1,320 ps/nm are concentrated in 5th-13th fiber spans and 6th-13th fiber spans, respectively, then the best performance is obtained. It is also confirmed that optimal net residual dispersion (NRD) controlled by precompensation and postcompensation are 10 ps/nm and -10 ps/nm, respectively, in all two cases, and the effective launching power range below 1 dB eye opening penalty (EOP) in the concentrated RDPS of 300 ps/nm and 1,320 ps/nm are improved by 2 dB and 6 dB than optical transmission links with the uniformly distributed RDPS, respectively.

Fluorescence Detection for Protoporphyrin IX Induced from 5-ALA and ALA-methyl ester in Incubated Liver Cancer Cells (간암 세포주에서 5-ALA 및 ALA-methyl ester에 의해 유도된 Protoporphyrin IX의 형광 검출)

  • Kim, Myung-Hwa;Kim, Jung-Mi;Kim, Hyun-Jeong;Lee, In-Seon;Kim, Kyung-Chan;Lee, Chang-Seop
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.168-173
    • /
    • 2007
  • To clarify the usefulness of fluorescent diagnosis for cancer, we investigated the optimal method of administrating 5-aminolevulinic acid (5-ALA), 5-aminolevulinic acid methyl ester (ALA-methyl ester) by analyzing fluorescence signal of Protoporphyrin IX (PpIX) in the cultured normal and cancer cells. 5-ALA and ALA-methyl ester was injected as a photosensitizer to the cancer liver cells (HepG2) and normal liver cells (Chang). Chang and HepG2 cells were incubated with various concentrations of 5-ALA and ALA-methyl ester (0-800 ${\mu}g/mL$). The accumulation of PpIX induced by 5-ALA and ALA-methyl ester was in HepG2 and Chang. The cell viability was measured by MTT assay. Fluorescence of PpIX in HepG2 cell was excited at a wavelength ($\lambda$ = 410 nm) and showed an emission spectrum at 603.2 nm, 660.8 nm and 603.2 nm, 661.4 nm which could be related to the PpIX generation induced by the applied 5-ALA and ALA-methyl ester, respectively. The experimental results showed that fluorescence signal of PpIX was proportional to the concentration of 5-ALA and ALA-methyl ester in tumor cells, but measured with low concentration in normal cells. Another results showed that the PpIX formation rate induced by ALA-methyl ester is higher than that of 5-ALA.

Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer (분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험)

  • Sung, Hyun-Ho;Seok, Dong-In;Jung, You-Hyun;Kim, Dae-Jung;Lee, Seok-Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.382-389
    • /
    • 2017
  • Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700~780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.

Optimal HPLC Condition for Simultaneous Determination of Catechins and Caffeine in Green Tea Extracts (녹차 함유 카테친 및 카페인 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun;Lee, Min-Seuk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.224-232
    • /
    • 2008
  • The health benefits associated with tea consumption have resulted in the wide inclusion of green tea extracts in botanical dietary supplements, which are widely consumed as adjuvants for complementary and alternative medicines. Tea contains polyphenols such as catechins or flavan-3-ols including (-)-epicatechin (EC), (-)-epigallocatechin (EGC), (-)-epicatechin gallate (ECG), and (-)-epigallocatechin gallate (EGCG), as well as the alkaloid, caffeine. The contents of catechins and caffeine in green tea are considered as a standard of quality evaluation of green tea. Therefor, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of catechins and caffeine in green tea extracts. The efficient HPLC analytical condition of catechins and caffeine contained green tea extracts was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 0.1% aqueous phosphoric acid, and mobile phase B, comprising 100% MeOH, and delivered at a flow rate of 1 mL/min as follows: $0{\sim}25\;min$, 80% A; $26{\sim}50\;min$, $80{\sim}70%$ A; 51 min, 80% A. $51{\sim}55\;min$, 80% A. The UV detection wavelength was set at 280 nm. The limit of detection (LOD) for catechins and caffeine standards were under 50 ng/mL.