송전계통을 고려한 발전기 예방정비계획 방법론에 관한 연구 (Method of Generator Maintenance Scheduling Considering Transmission System)

  • 한석만;신영균;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.104-106
    • /
    • 2004
  • In competitive electricity markets, the System Operator (SO) coordinates the overall maintenance schedules whenever the collective maintenance schedule reported to SO by Gencos in the pool does not satisfy the specified operating criteria, such as system reliability or supply adequacy. In this paper, we divide maintenance schedule problem into master-problem and sub-problem. Master-problem is schedule coordination and sub-problem is DC-optimal power flow. If sub-problem is infeasible, we use the algorithm of modifying operating criteria of master-problem.

  • PDF

EXPERIMENT AND SIMULATION OF A WIND-DRIVEN REVERSE OSMOSIS DESALINATION SYSTEM

  • Park, Sang-Jin;Clark C.K. Liu
    • Water Engineering Research
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2003
  • A mathematical model was developed to simulate the performance of a prototype wind-powered reverse osmosis desalination system. The model consists of two sub-models operated in a series. The first sub-model is the wind-energy conversion sub-model, which has wind energy and feed water as its input and pressurized feed water as its output. The second sub-model is a reverse osmosis (RO) process sub-model, with pressurized feed water as its input and the flow and salinity of the product water or permeate as its output. Model coefficients were determined based on field experiments of a prototype wind powered RO desalination system of the University of Hawaii, from June to December 2001. The mathematical model developed by this study predicts the performance of wind-powered RO desalination systems under different design conditions. The system optimization is achieved using a linear programming approach. Based on the results of system optimization, a design guide is prepared, which can be used by both manufacturer and end-user of the wind-driven reverse osmosis system.

  • PDF

대향타겟식 스퍼터링법을 이용한 AIN 박막의 제작

  • 금민종;추순남;최명규;이원식;김경환
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2005년도 추계 학술대회
    • /
    • pp.89-92
    • /
    • 2005
  • The AIN/AI thin films were prepared at various conditions, such as $N_2$ gas flow rate [$N_2(N_2+Ar)$] from 0.6 to 0.9, a substrate temperature ranging from room temperature to $300^{\circ}C$ and working pressure 1mTorr. We estimated crystallographic characteristics and c-axis preferred orientations of AIN/AI thin films as function of AI electrode surface roughness. The optimal processing conditions for AI electrode were found at substrate temperature of $300^{\circ}C$ sputtering power of 100W and a working pressure of 2mTorr. In these conditions, we obtained the c-axis preferred orientation of $AIN/AI/SiO_2/Si$ thin film about 4 degree.

  • PDF

Selection of a carrying agent for obtaining radioactive methyliodide vapors under dynamic conditions

  • Obruchikov, Alexander V.;Merkushkin, Aleksei O.;Magomedbekov, Eldar P.;Anurova, Olga M.;Vanina, Elena A.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2761-2766
    • /
    • 2021
  • A method for preparing "reagent" for radioactive methyliodide vapors production using an isotopic exchange reaction has been developed. Based on the obtained data of the isotopic exchange efficiency and hydraulic resistance, white fused alumina (700-840 ㎛) was selected as the carrying agent material for "reagent" production. The radioiodine isotopic exchange dependences on such parameters as temperature, gas flow velocity, and the methyliodide concentration in it were determined. Optimal conditions have been selected to achieve 85% of the isotopic exchange rate in 1 h of the experiment. The obtained data allowed to develop an approach to the test of iodine filters for nuclear power plants and to determine their efficiency.

Hierarchical Control Scheme for Three-Port Multidirectional DC-DC Converters in Bipolar DC Microgrids

  • Ahmadi, Taha;Hamzeh, Mohsen;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1595-1607
    • /
    • 2018
  • In this paper, a hierarchical control strategy is introduced to control a new three-port multidirectional DC-DC converter for integrating an energy storage system (ESS) to a bipolar DC microgrid (BPDCMG). The proposed converter provides a voltage-balancing function for the BPDCMG and adjusts the states of charge (SoC) of the ESS. Previous studies tend to balance the voltage of the BPDCMG buses with active sources or by transferring power from one bus to another. Furthermore, the batteries available in BPDCMGs were charged equally by both buses. However, this power sharing method does not guarantee efficient operation of the whole system. In order to achieve a higher efficiency and lower energy losses, a triple-layer hierarchical control strategy, including a primary droop controller, a secondary voltage restoration controller and a tertiary optimization controller are proposed. Thanks to the multi-functional operation of the proposed converter, its conversion stages are reduced. Furthermore, the efficiency and weight of the system are both improved. Therefore, this converter has a significant capability to be used in portable BPDCMGs such as electric DC ships. The converter modes are analyzed and small-signal models of the converter are extracted. Comprehensive simulation studies are carried out and a BPDCMG laboratory setup is implemented in order to validate the effectiveness of the proposed converter and its hierarchical control strategy. Simulation and experimental results show that using the proposed converter mitigates voltage imbalances. As a result, the system efficiency is improved by using the hierarchical optimal power flow control.

Effects of Hydrogen Plasma Treatment of the Underlying TaSiN Film Surface on the Copper Nucleation in Copper MOCVD

  • Park, Hyun-Ah;Lim, Jong-Min;Lee, Chong-Mu
    • 한국세라믹학회지
    • /
    • 제41권6호
    • /
    • pp.435-438
    • /
    • 2004
  • MOCVD is one of the major deposition techniques for Cu thin films and Ta-Si-N is one of promising barrier metal candidates for Cu with high thermal stability. Effects of hydrogen plasma pretreatment of the underlying Ta-Si-N film surface on the Cu nucleation in Cu MOCVD were investigated using scanning electron microscopy, X-ray photoelectron spectroscopy and Auger electron emission spectrometry analyses. Cu nucleation in MOCVD is enhanced as the rf-power and the plasma exposure time are increased in the hydrogen plasma pretreatment. The optimal plasma treatment process condition is the rf-power of 40 Wand the plasma exposure time of 2 min. The hydrogen gas flow rate in the hydrogen plasma pretreatment process does not affect Cu nucleation much. The mechanism through which Cu nucleation is enhanced by the hydrogen plasma pretreatment of the Ta-Si-N film surface is that the nitrogen and oxygen atoms at the Ta-Si-N film surface are effectively removed by the plasma treatment. Consequently the chemical composition was changed from Ta-Si-N(O) into Ta-Si at the Ta-Si-N film surface, which is favorable for Cu nucleation.

배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘 (Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network)

  • 김영인;임일형;최면송;이승재;이성우;권성철
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

부분분사 마이크로 축류형터빈에서의 익형각 효과에 관한 연구 (Effect of Blade Angles on a Micro Axial-Type Turbine Operated in a Low Partial Admission Rate)

  • 조수용;조봉수;조종현
    • 한국추진공학회지
    • /
    • 제11권4호
    • /
    • pp.10-18
    • /
    • 2007
  • 본 연구에 채택된 마이크로터빈은 축류형 터빈으로 2단으로 구성되어져 있으며 로터 유로에서의 평균반경이 8.4 mm이다. 이러한 소형 터빈은 마이크로 동력시스템의 드라이브로 사용되어질 수 있으며 무부하 상태에서 100,000 RPM의 회전속도에 도달한다. 하지만 낮은 부분분사에서 작동하므로 동익과 정익의 익형각에 따라 성능의 변화가 발생되어진다. 따라서 노즐, 정익, 동익의 익형각을 변경하면서 비출력과 총 비토오크를 측정하여 각각의 성능을 분석하였다. 성능실험의 결과에 의하면 동익 익형각의 변화에 따라 총 비토오크가 15%까지 변경되어졌으며 최적의 입사각은 $10.3^{\circ}$ 정도였다.

PRA를 이용한 확률론적 신뢰도 평가에 관한 연구 (A Study on Probabilistic Reliability Evaluation by Using PRA)

  • 권중지;트란트룽틴;정상헌;시보;최재석;차준민;윤용태;최홍석;전동훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.27-29
    • /
    • 2006
  • This paper deals with the application of the concept of POM to analysis of power system behavior and describes a practical method of PRA for KEPCO system. This paper presents not only marginal power flow evaluation of KEPCO system in view point of physical and operation mode by using Physical and Operational Margins (POM Ver. 2.2), which is developed by V&R Energy System Research, but also by using Probabilistic Reliability Assessment (PRA Ver.3.1), which is developed by EPRI. The ability of the method to provide insights on root causes, weak points and regional causes and effects was shown. The approach offers fast and accurate determination of bottlenecks in the transmission network and optimal mitigation measures to alleviate the identified violations.

  • PDF

Bandwidth-Related Optimization in High-Speed Frequency Dividers using SiGe Technology

  • Nan, Chao-Zhou;Yu, Xiao-Peng;Lim, Wei-Meng;Hu, Bo-Yu;Lu, Zheng-Hao;Liu, Yang;Yeo, Kiat-Seng
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.107-116
    • /
    • 2012
  • In this paper, the trade-off related to bandwidth of high-speed common-mode logic frequency divider is analyzed in detail. A method to optimize the operating frequency, band-width as well as power consumption is proposed. This method is based on bipolar device characteristics, whereby a negative resistance model can be used to estimate the optimal normalized upper frequency and lower frequency of frequency dividers under different conditions, which is conventionally ignored in literatures. This method provides a simple but efficient procedure in designing high performance frequency dividers for different applications. To verify the proposed method, a static divide-by-2 at millimeter wave ranges is implemented in 180 nm SiGe technology. Measurement results of the divider demonstrate significant improvement in the figure of merit as compared with literatures.