• Title/Summary/Keyword: optimal methods

Search Result 5,157, Processing Time 0.047 seconds

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.

Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture (이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석)

  • Oh, Jung-Ran;Woo, Yi-Hyung;Lee, Sung-Bok;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.359-371
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the stress distribution in mandibular implant overdentures with telescopic crowns compared to bar attachment. Material and methods: Three-dimensional finite element models consisting of the mandibular bone, 4 implants, and primary bar-splinted superstructure or secondary splinted superstructure with telescopic crowns were created. Vertical and oblique loads were directed onto the occlusal areas of the superstructures to simulate the maximal intercuspal contacts and working contacts such as group function occlusion. Maximum stress and stress distribution were analysed in mandibular bone, implant abutments, and superstructures. Results: 1. In comparison of von Mises stress on mandibular bone, telescopic overdenture had a little lower stress values in vertical load and working side load except oblique load. In the mandible, the telescopic overdenture distributed more uniform stress than the bar overdenture. 2. In comparison of von Mises stress on implant abutments, telescopic overdenture had much lower stress values in all load conditions. In implant abutments, the telescopic overdenture distributed stress similar to the bar overdenture. Stress was concentrated on the distal surfaces of the posterior implant abutments in both mandibular overdentures. 3. In comparison of von Mises stress on superstructures, the telescopic overdenture had much more stress values in all load conditions. However, the telescopic overdenture distributed more uniform stress on superstructure than the bar overdenture. In the bar overdenture, stress was concentrated on each cental area of bar structures and connected area between implant abutments and bar structures. Conclusion: In the results of this study, the telescopic overdenture had lower stress values than the bar overdenture in mandibular bone and implant abutments, but more stress values in superstructures. However, if optimal material was selected in making superstructures, the telescopic overdenture was compared to the bar overdenture in stress distribution.

A Study on the Automation and Optimization of 9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) Guanine Synthesis (9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) guanine 합성의 자동화와 최적화에 관한 연구)

  • An, Jae-Seok;Hong, Sung-Tack;Kang, Se-Hun;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2011
  • Purpose: The HSV1-tk reporter gene system is the most widely used system because of its advantage is that it is possible to monitor directly without the introduction of a separate reporter gene in case of HSV1-tk suicide gene therapy. This study was performed to automate 9-(4-[$^{18}F$] Fluoro-3-hydroxymethylbutyl) guanine ([$^{18}F$] FHBG) that are widely used as substrate for the HSV1-tk reporter gene in living organisms with positron emission tomography (PET) and find the optimized conditions of synthesis. Materials and Methods: Fully automated synthesis of [$^{18}F$] FHBG was performed using Explora-RN (CTI, USA) module. We have changed of reaction time (3, 5, 10 min) and temperature (110, 120, $130^{\circ}C$) for the optimized conditions of synthesis. Also we experimented to find the optimal concentration of precursor (5, 7, 10 mg). Results: [$^{18}F$] FHBG was purified by HPLC system and collected at around 10-12 min. Synthesis using Explora-RN module showed a $32.0{\pm}1.2%$ yield of radiochemical (decay corrected), the purity was greater than 98%. And the entire synthesis time was less than 48 min. Temperature of the highest synthesis yield was $130^{\circ}C$, reaction time was 5 minutes and concentration of precursor was 10 mg (recommended volume in manual) (n=36). In contrast to radiochemical yield of precursor 10 mg ($32{\pm}1.2%$), yield of 5 and 7 mg precursor was unstable. Conclusion: Automation of [$^{18}F$] FHBG synthesis at Explora-RN module has been completed. In addition, we were able to obtain optimized reaction time, temperature and concentration of precursor. Therefore this study would be provided more rapid synthesis and higher radiochemical yield.

  • PDF

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Comparison of the retention of the full veneer casted gold crowns with varying convergence angle, crown length and dental cements (수렴각과 치관 길이를 달리한 금속 다이상에서 치과용 시멘트 합착 후 전부주조관의 유지력 비교)

  • Yun, Jung-Ho;Cho, Jin-Hyung;Kim, Jee-Hwan;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The aim of this research was to establish the effect and variation in differing convergence angle and length of abutment on the retention of full veneer casted gold crown. Materials and methods: Two different length,5 mm and 10 mm in height with convergence angles of 5, 10, 15 and 25 degrees crowns were fabricated. Cementation was done using cements; zinc phosphate cement (Fleck's zinc phosphate cement), resin-modified glass ionomer cement (Vitremer) and resin cement (Panavia 21). These were tested for tensile force at the point of separation by using Instron Universal Testing Machine. Statistical analysis was done by SAS 6.04 package. Results: In all cements the mean retention decreased with significant difference on increase of convergence angle (P<.05). Increase in every 5 degree-convergence angel the retention rate decreased with resin-modified glass ionomer cement of 15.9% and resin cement of 14.8%. With zinc phosphate cement, there was largest decreasing rate of mean retention of 25.5% between convergence angles from 5 degree to 10 degree. When the crown length increased from 5 mm to 10 mm, the retention increased with the significant difference in the same convergence angle and in all types of cement used (P<.05). Conclusion: The retention was strongly dependent on geometric factors of abutment. Much care is required in choosing cements for an optimal retention in abutments with different convergence angles and crown lengths.

Cultural characteristics on collected strains of Lentinula edodes and correlation with mycelial browning (표고 수집균주의 재배적 특성 및 갈변과의 상관관계)

  • Kim, Young-Ho;Jhune, Chang-Sung;Park, Soo-Cheol;You, Chang-Hyun;Sung, Jae-Mo;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.9 no.4
    • /
    • pp.145-154
    • /
    • 2011
  • Shiitake mushroom (Lentinula edodes) is usually cultivated on the oak log. Log cultivation of this mushroom is getting difficult to get oak logs and has a weak point of its long cultivation period. Recently sawdust cultivation is getting increase. It is important to make mycelia browning on the substrate surface. This browned surface in sawdust cultivation plays an important role like as artificial bark of the oak log, which protects the other pests and suppresses water evaporation in the substrate. The period for mycelia browning is so long that the sawdust cultivation of Shiitake mushroom can not spread well into the mushroom farms. The development of methods for the rapid mycelia browning is quite required. In this article we would like to find cultural characteristics of collected strains and to see the correlation with mycelial browning. Mycelial growth in the media was different according to kinds of media and strains. The optimal temperature on mycelial growth was $20-25^{\circ}C$. Browning patterns of mycelium under 200 Lux seemed to be used for a key to differentiate the strains for sawdust cultivation. Browning period was 30-40 days in the agar media and 70-100 days in the sawdust bag cultivation. When we considered the productivity and the other characteristics, ASI 3046 is the best for the bag cultivation. Significance between mycelial growth and browning was not accepted, but that of mycelial growth between on PDA and sawdust was accepted. Browning period on the PDA and sawdust showed a strong relationships. These results suggested that the browning habits could not be depend on the difference of media, but on their own properties. To select the strain showed fast browning can be done by using agar media for saving time.

Development of an Efficient In Vitro Screening Method for Selection of Resistant Lily Cultivars Against Fusarium oxysporum f. sp. lilii (백합 구근부패병 저항성 검정을 위한 기내 간편 검정법 개발)

  • Jang, Ji-Young;Moon, Ki-Beom;Ha, Jang-Ho;Park, Ji-Sun;Kim, Mi-Jin;Jeon, Jae-Heung;Lee, Geung-Joo;Kim, Hyun-Soon
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.883-890
    • /
    • 2015
  • The soilborne fungus Fusarium oxysporum f. sp. lilii (Fol) is a serious threat to all lily cultivars, especially infecting bulbs and flowers. It has become increasingly important to develop varieties resistant against the bulb rot disease. Genetic diversity of cultivars and reliable screening methods are required for this purpose. Here, an efficient in vitro screening system for evaluating resistance to Fol in 38 in vitro-grown lily plants was investigated. Various factors including culture conditions of Fol, inoculum density, appropriate plant materials, inoculation method and duration, and incubation period of plant materials after inoculation were combined to optimize the screening method. As a result, we suggest optimal conditions for an in vitro screening system for the selection of Fol-resistant lily cultivars as follows. Fol was grown on potato dextrose agar (PDA) medium for 6 days at $25^{\circ}C$ in darkness and used as working inoculation. Spore suspensions were prepared (inoculum density: $1.0{\times}10^4$ $spores{\cdot}mL^{-1}$), and then leaf segments $1.5{\times}2.0cm^2$ were inoculated by dipping for 22 hours at $25^{\circ}C$ in dark. Later, leaves were cultured on 0.6% agar plates at $25^{\circ}C$ and 50% humidity with a photoperiod of 16 hours light/8 hours dark (fluence rate of $40{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) to examine the progress of bulb rot. After 7 days, disease levels were classified into indices 1 (no symptom) to 6 (serious bulb rot). Soil inoculation of Fol carried out with resistant or susceptible lily cultivars that had been selected through in vitro screening confirmed the reproducibility of results. Therefore, the in vitro screening method established in this study is efficient and reliable for selection of lily cultivars resistant against bulb rot disease.

Mapping Precise Two-dimensional Surface Deformation on Kilauea Volcano, Hawaii using ALOS2 PALSAR2 Spotlight SAR Interferometry (ALOS-2 PALSAR-2 Spotlight 영상의 위성레이더 간섭기법을 활용한 킬라우에아 화산의 정밀 2차원 지표변위 매핑)

  • Hong, Seong-Jae;Baek, Won-Kyung;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1235-1249
    • /
    • 2019
  • Kilauea Volcano is one of the most active volcano in the world. In this study, we used the ALOS-2 PALSAR-2 satellite imagery to measure the surface deformation occurring near the summit of the Kilauea volcano from 2015 to 2017. In order to measure two-dimensional surface deformation, interferometric synthetic aperture radar (InSAR) and multiple aperture SAR interferometry (MAI) methods were performed using two interferometric pairs. To improve the precision of 2D measurement, we compared root-mean-squared deviation (RMSD) of the difference of measurement value as we change the effective antenna length and normalized squint value, which are factors that can affect the measurement performance of the MAI method. Through the compare, the values of the factors, which can measure deformation most precisely, were selected. After select optimal values of the factors, the RMSD values of the difference of the MAI measurement were decreased from 4.07 cm to 2.05 cm. In each interferograms, the maximum deformation in line-of-sight direction is -28.6 cm and -27.3 cm, respectively, and the maximum deformation in the along-track direction is 20.2 cm and 20.8 cm, in the opposite direction is -24.9 cm and -24.3 cm, respectively. After stacking the two interferograms, two-dimensional surface deformation mapping was performed, and a maximum surface deformation of approximately 30.4 cm was measured in the northwest direction. In addition, large deformation of more than 20 cm were measured in all directions. The measurement results show that the risk of eruption activity is increasing in Kilauea Volcano. The measurements of the surface deformation of Kilauea volcano from 2015 to 2017 are expected to be helpful for the study of the eruption activity of Kilauea volcano in the future.

tans-Resveratrol Content of Varieties and Growth Period in Peanut (땅콩 품종 및 생육기별 trans-Resveratrol 함량)

  • Lee, Mi-Ja;Cheong, Young-Keun;Kim, Hyung-Soon;Park, Ki-Hun;Doo, Hong-Soo;Suh, Duck-Yong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.6
    • /
    • pp.429-433
    • /
    • 2003
  • trans-Resveratrol(3,5,4'-trihydroxystilbene) is phenolic compound present in grapes, wines, and peanuts, has been reported to have health benefits including anticarcinogenic effects, protection against cardiovascular diseases and reduced cancer risk. A simple method for the quantitative extraction of trans-resveratrol from peanut has been developed. Optimal conditions for extraction were investigated. Type of solvent, time, and temperature assayed influenced trans-resveratrol yield. Adequate extraction condition was decided to ethanol/water (80:20v/v) maintained at $25^{\circ}C$ for 45 min. After extraction, the protocol consists of sample preparation using a $\textrm{C}_{18}$ solid-phase extraction (SPE) cartridge after concentrate with rotary evaporator and quantified by reversed phase HPLC using a $\textrm{C}_{18}$ column at 308 nm. Analytical methods for measuring trans-resveratrol in peanut were adapted to isolate, identify, and quantify trans-resveratrol in 11 peanut varieties by HPLC (high-performance liquid chromatography) with UV detector, The 11 peanut varieties content ranged from 0.018 to 1.125 $\mu\textrm{g}/\textrm{g}$ with an average of 0.289 $\mu\textrm{g}/\textrm{g}$. The contents were higher in the seeds with than without testa, regardless of varieties. The trans-resveratrol content was Higher in 110, 130 days after sowing than that of other period.

A comparative study of electric and manual toothbrushes on oral hygiene status in fixed orthodontic patients (고정식 교정 환자에서 전동치솔 효과에 관한 연구)

  • Park, Chang-Hun;Hwang, Hyeon-Shik;Lee, Ki-Heon;Hong, Suk_jin
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.363-370
    • /
    • 2004
  • Patients with fixed orthodontic appliances frequently have increased levels of plaque accumulation leading to the possibility of gingivitis or enamel decalcification. Although many methods may be helpful in reducing dental plaque formation, the optimal mechanical removal of plaque is the most important factor during orthodontic treatment. The purpose of this study was to evaluate the efficacy of an electric toothbrush (with a specially designed orthodontic brush head) compared to a manual toothbrush in controlling plaque and gingivitis for patients with fixed orthodontic appliances. Oral hygiene status was measured in thirty-four patients using a plaque index, a gingival index and a bleeding index, before and four weeks after the attachment of fixed orthodontic appliances. Patients were randomly divided into two groups: electric and manual toothbrush groups. Oral hygiene instruction was given according to the type of toothbrush used. The Braun Oral-B D9511 with Braun Oral-B Ortho OD 15-1 brush head was used as the electric toothbrush while the Butler G.U.M. 124 was given as the manual toothbrush. After four md eight weeks, oral hygiene status was measured again. Through a comparison between the electric and the manual toothbrush groups, the following results were obtained. 1. All oral hygiene indices showed an increasing tendency after four weeks of fixed orthodontic appliance. 2. All indices presented a decreasing tendency four and eight weeks after oral hygiene instruction. 3. In case of the gingival index and bleeding index, the decreasing tendency did not show a statistically significant difference between the electric and the manual toothbrush groups. 4. The decreasing tendency of plaque index presented a statistically significant difference between the two groups, showing that the electric toothbrush was more effective in terms of oral hygiene. These findings suggest that an electric toothbrush is useful to orthodontic patients with fixed appliances.